AQUASKY · NETWORK QA

Quality assurance report

Pipe_Nodes · Pulkovo 1942(58) / Stereo70
Generated
10 Oct 2026, 13:37
Issues found1616
Resolved0
Remaining1616
Open errors1380

0% of detected issues resolved · open: 1380 errors, 234 warnings, 2 info · 0 confirmed awaiting correction · 0 marked not an issue · 0 data edit(s) applied · checked: 5085 junctions, 1354 components, 77 disconnected_parts, 952 crossings, 3754 pipes

Network overview

605958575655545352515049484746454443424140393837363534333231302928272625242322212019181716151413121110987654321

The 60 highest-priority issues are numbered as in the list below; smaller dots are the rest. Red = error, amber = warning, blue = info, green = resolved. Dashed lines are inactive or closed pipes.

Summary by category and severity

CategoryErrorWarningInfoFoundResolvedRemaining
Topology
Connectivity of the pipe network: unconnected ends, missing junctions, disconnected parts, crossings
13752211159701597
Completeness
Missing or placeholder attribute values (null, 0, 'unknown')
18110010
Plausibility
Values that are out of range or inconsistent with each other or with the geometry
5505
Geometry
Shape of the features: zero length, duplicates, overlaps, multi-part or self-intersecting lines
4404

Detected data structure

Layers and fields were recognised automatically from the uploaded data (no manual mapping).

LayerRecognised asField roles
Junction_Rev03
Point · 5085
Junctions / nodes
100% confidence
id = Junc_ID, elevation = Elevation, demand = BaseDemand, x = X_Coord, y = Y_Coord
Pipe_Functional_Rev04
MultiLineString · 3754
Pipes
100% confidence
id = Pipe_ID2, from = Starting_N, to = Ending_N, length = Length, material = Material, diameter = Size, outer_diameter = OD, inner_diameter = ID, roughness = HW_C, year = year, age = Age_yr, function = Function, pressure_class = PN_Class, status = Status

Issue list (by priority)

#SeverityCheckLayer / assetFinding & suggested actionStatus
1ERROR
P100
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
67 pipes near 56672-2
67 pipe(s), 952 m in total incl. 34 main(s), are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
2ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
116109
Junction 116109 (degree 1) lies on pipe 77106 (DN 160, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (37 m).
→ Split pipe 77106 at junction 116109 so both are connected.
Open
3ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
116112
Junction 116112 (degree 1) lies on pipe 77106 (DN 160, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 77106 at junction 116112 so both are connected.
Open
4ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
12
Junction 12 (degree 1) lies on pipe 56418-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56418-2 at junction 12 so both are connected.
Open
5ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
13
Junction 13 (degree 1) lies on pipe 56418-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56418-2 at junction 13 so both are connected.
Open
6ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
14
Junction 14 (degree 1) lies on pipe 56418-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 56418-2 at junction 14 so both are connected.
Open
7ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
14571
Junction 14571 (degree 1) lies on pipe 52847 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (17 m).
→ Split pipe 52847 at junction 14571 so both are connected.
Open
8ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
14573
Junction 14573 (degree 1) lies on pipe 56493-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 17 pipe(s) (426 m).
→ Split pipe 56493-2 at junction 14573 so both are connected.
Open
9ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
14576
Junction 14576 (degree 1) lies on pipe 52847 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (20 m).
→ Split pipe 52847 at junction 14576 so both are connected.
Open
10ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
14628
Junction 14628 (degree 1) lies on pipe 56493-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 56493-2 at junction 14628 so both are connected.
Open
11ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18657
Junction 18657 (degree 2) lies on pipe 95312 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (56 m).
→ Split pipe 95312 at junction 18657 so both are connected.
Open
12ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18660
Junction 18660 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 95313 at junction 18660 so both are connected.
Open
13ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18662
Junction 18662 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 95313 at junction 18662 so both are connected.
Open
14ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18664
Junction 18664 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (20 m).
→ Split pipe 95313 at junction 18664 so both are connected.
Open
15ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18666
Junction 18666 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (21 m).
→ Split pipe 95313 at junction 18666 so both are connected.
Open
16ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18668
Junction 18668 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Split pipe 95313 at junction 18668 so both are connected.
Open
17ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18670
Junction 18670 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 95313 at junction 18670 so both are connected.
Open
18ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18672
Junction 18672 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Split pipe 95313 at junction 18672 so both are connected.
Open
19ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18674
Junction 18674 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 95354 at junction 18674 so both are connected.
Open
20ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18676
Junction 18676 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 95354 at junction 18676 so both are connected.
Open
21ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18678
Junction 18678 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 95354 at junction 18678 so both are connected.
Open
22ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18680
Junction 18680 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 95354 at junction 18680 so both are connected.
Open
23ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18682
Junction 18682 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Split pipe 95354 at junction 18682 so both are connected.
Open
24ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18684
Junction 18684 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 95354 at junction 18684 so both are connected.
Open
25ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18686
Junction 18686 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 95313 at junction 18686 so both are connected.
Open
26ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18688
Junction 18688 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 95313 at junction 18688 so both are connected.
Open
27ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18690
Junction 18690 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 95354 at junction 18690 so both are connected.
Open
28ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18692
Junction 18692 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 95354 at junction 18692 so both are connected.
Open
29ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18694
Junction 18694 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 95354 at junction 18694 so both are connected.
Open
30ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18696
Junction 18696 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 95354 at junction 18696 so both are connected.
Open
31ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18698
Junction 18698 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 95354 at junction 18698 so both are connected.
Open
32ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18700
Junction 18700 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 95354 at junction 18700 so both are connected.
Open
33ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18702
Junction 18702 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 95354 at junction 18702 so both are connected.
Open
34ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18704
Junction 18704 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 95354 at junction 18704 so both are connected.
Open
35ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18706
Junction 18706 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 95354 at junction 18706 so both are connected.
Open
36ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18708
Junction 18708 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 95354 at junction 18708 so both are connected.
Open
37ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18710
Junction 18710 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 95354 at junction 18710 so both are connected.
Open
38ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18712
Junction 18712 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 95354 at junction 18712 so both are connected.
Open
39ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18714
Junction 18714 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 95354 at junction 18714 so both are connected.
Open
40ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18716
Junction 18716 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 95354 at junction 18716 so both are connected.
Open
41ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18718
Junction 18718 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 95354 at junction 18718 so both are connected.
Open
42ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18720
Junction 18720 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 95354 at junction 18720 so both are connected.
Open
43ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18767
Junction 18767 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 95313 at junction 18767 so both are connected.
Open
44ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18770
Junction 18770 (degree 1) lies on pipe 95312 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Split pipe 95312 at junction 18770 so both are connected.
Open
45ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18771
Junction 18771 (degree 1) lies on pipe 95312 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 95312 at junction 18771 so both are connected.
Open
46ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18773
Junction 18773 (degree 1) lies on pipe 95312 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 95312 at junction 18773 so both are connected.
Open
47ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18775
Junction 18775 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 95313 at junction 18775 so both are connected.
Open
48ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18777
Junction 18777 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 95313 at junction 18777 so both are connected.
Open
49ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18779
Junction 18779 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 95313 at junction 18779 so both are connected.
Open
50ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18781
Junction 18781 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 95313 at junction 18781 so both are connected.
Open
51ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18783
Junction 18783 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 95313 at junction 18783 so both are connected.
Open
52ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18785
Junction 18785 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 95313 at junction 18785 so both are connected.
Open
53ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18788
Junction 18788 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 95313 at junction 18788 so both are connected.
Open
54ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18789
Junction 18789 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 95313 at junction 18789 so both are connected.
Open
55ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18791
Junction 18791 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 95313 at junction 18791 so both are connected.
Open
56ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
18793
Junction 18793 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 95313 at junction 18793 so both are connected.
Open
57ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
19603
Junction 19603 (degree 1) lies on pipe 93645 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 93645 at junction 19603 so both are connected.
Open
58ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
19605
Junction 19605 (degree 1) lies on pipe 52817 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 6 pipe(s) (2,996 m).
→ Split pipe 52817 at junction 19605 so both are connected.
Open
59ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
19999
Junction 19999 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 95313 at junction 19999 so both are connected.
Open
60ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
20001
Junction 20001 (degree 1) lies on pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Split pipe 95313 at junction 20001 so both are connected.
Open
61ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
20003
Junction 20003 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Split pipe 95354 at junction 20003 so both are connected.
Open
62ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
20005
Junction 20005 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Split pipe 95354 at junction 20005 so both are connected.
Open
63ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
20007
Junction 20007 (degree 1) lies on pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Split pipe 95354 at junction 20007 so both are connected.
Open
64ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
20389
Junction 20389 (degree 1) lies on pipe 93643 (DN 355, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 93643 at junction 20389 so both are connected.
Open
65ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
25080
Junction 25080 (degree 1) lies on pipe 52859 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52859 at junction 25080 so both are connected.
Open
66ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
25082
Junction 25082 (degree 1) lies on pipe 56477 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Split pipe 56477 at junction 25082 so both are connected.
Open
67ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
33502
Junction 33502 (degree 1) lies on pipe 102634-3 (DN 50, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 102634-3 at junction 33502 so both are connected.
Open
68ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
66680
Junction 66680 (degree 1) lies on pipe 56447 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56447 at junction 66680 so both are connected.
Open
69ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
66816
Junction 66816 (degree 1) lies on pipe 89522-2 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (128 m).
→ Split pipe 89522-2 at junction 66816 so both are connected.
Open
70ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
72749
Junction 72749 (degree 1) lies on pipe 56431 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (32 m).
→ Split pipe 56431 at junction 72749 so both are connected.
Open
71ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
72858
Junction 72858 (degree 1) lies on pipe 56633-19 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 179 pipe(s) (3,395 m).
→ Split pipe 56633-19 at junction 72858 so both are connected.
Open
72ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
72862
Junction 72862 (degree 2) lies on pipe 53745 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 53745 at junction 72862 so both are connected.
Open
73ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
75888
Junction 75888 (degree 1) lies on pipe 52910-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 7 pipe(s) (182 m).
→ Split pipe 52910-2 at junction 75888 so both are connected.
Open
74ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
76015
Junction 76015 (degree 1) lies on pipe 89498-4 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 22 pipe(s) (371 m).
→ Split pipe 89498-4 at junction 76015 so both are connected.
Open
75ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
76022
Junction 76022 (degree 1) lies on pipe 52877 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 22 pipe(s) (371 m).
→ Split pipe 52877 at junction 76022 so both are connected.
Open
76ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
76028
Junction 76028 (degree 1) lies on pipe 52821 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 31 pipe(s) (315 m).
→ Split pipe 52821 at junction 76028 so both are connected.
Open
77ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
77957
Junction 77957 (degree 1) lies on pipe 89469-12 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 89469-12 at junction 77957 so both are connected.
Open
78ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
77963
Junction 77963 (degree 1) lies on pipe 89511-19 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Split pipe 89511-19 at junction 77963 so both are connected.
Open
79ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
78258
Junction 78258 (degree 1) lies on pipe 89522-1 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 89522-1 at junction 78258 so both are connected.
Open
80ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
78639
Junction 78639 (degree 1) lies on pipe 89498-2 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 89498-2 at junction 78639 so both are connected.
Open
81ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
81371
Junction 81371 (degree 1) lies on pipe 56396 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (4 m).
→ Split pipe 56396 at junction 81371 so both are connected.
Open
82ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8454
Junction 8454 (degree 1) lies on pipe 52889 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 29 pipe(s) (207 m).
→ Split pipe 52889 at junction 8454 so both are connected.
Open
83ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8462
Junction 8462 (degree 1) lies on pipe 89469-9 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 89469-9 at junction 8462 so both are connected.
Open
84ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8463
Junction 8463 (degree 1) lies on pipe 89469-9 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 89469-9 at junction 8463 so both are connected.
Open
85ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8469
Junction 8469 (degree 1) lies on pipe 89469-5 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 89469-5 at junction 8469 so both are connected.
Open
86ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8514
Junction 8514 (degree 1) lies on pipe 56384 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 179 pipe(s) (3,395 m).
→ Split pipe 56384 at junction 8514 so both are connected.
Open
87ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86430
Junction 86430 (degree 1) lies on pipe 53503 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (21 m).
→ Split pipe 53503 at junction 86430 so both are connected.
Open
88ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86432
Junction 86432 (degree 2) lies on pipe 53503 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (27 m).
→ Split pipe 53503 at junction 86432 so both are connected.
Open
89ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86434
Junction 86434 (degree 2) lies on pipe 53503 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (26 m).
→ Split pipe 53503 at junction 86434 so both are connected.
Open
90ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86436
Junction 86436 (degree 1) lies on pipe 53503 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 53503 at junction 86436 so both are connected.
Open
91ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86438
Junction 86438 (degree 1) lies on pipe 53503 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Split pipe 53503 at junction 86438 so both are connected.
Open
92ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86440
Junction 86440 (degree 1) lies on pipe 53503 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (26 m).
→ Split pipe 53503 at junction 86440 so both are connected.
Open
93ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86442
Junction 86442 (degree 1) lies on pipe 53503 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (21 m).
→ Split pipe 53503 at junction 86442 so both are connected.
Open
94ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86445
Junction 86445 (degree 2) lies on pipe 53503 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (23 m).
→ Split pipe 53503 at junction 86445 so both are connected.
Open
95ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86449
Junction 86449 (degree 1) lies on pipe 53503 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 53503 at junction 86449 so both are connected.
Open
96ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86451
Junction 86451 (degree 1) lies on pipe 53503 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 53503 at junction 86451 so both are connected.
Open
97ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86453
Junction 86453 (degree 1) lies on pipe 53503 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 53503 at junction 86453 so both are connected.
Open
98ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86455
Junction 86455 (degree 1) lies on pipe 53503 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 53503 at junction 86455 so both are connected.
Open
99ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86457
Junction 86457 (degree 1) lies on pipe 53503 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 53503 at junction 86457 so both are connected.
Open
100ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86459
Junction 86459 (degree 1) lies on pipe 53503 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53503 at junction 86459 so both are connected.
Open
101ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86461
Junction 86461 (degree 1) lies on pipe 53503 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 53503 at junction 86461 so both are connected.
Open
102ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86463
Junction 86463 (degree 1) lies on pipe 53503 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53503 at junction 86463 so both are connected.
Open
103ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86465
Junction 86465 (degree 1) lies on pipe 53503 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 53503 at junction 86465 so both are connected.
Open
104ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86467
Junction 86467 (degree 1) lies on pipe 53505 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 53505 at junction 86467 so both are connected.
Open
105ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86717
Junction 86717 (degree 1) lies on pipe 56418-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56418-2 at junction 86717 so both are connected.
Open
106ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86721
Junction 86721 (degree 1) lies on pipe 56418-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56418-2 at junction 86721 so both are connected.
Open
107ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86729
Junction 86729 (degree 1) lies on pipe 56418-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56418-2 at junction 86729 so both are connected.
Open
108ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86731
Junction 86731 (degree 1) lies on pipe 56418-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56418-2 at junction 86731 so both are connected.
Open
109ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86733
Junction 86733 (degree 1) lies on pipe 56418-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56418-2 at junction 86733 so both are connected.
Open
110ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86737
Junction 86737 (degree 1) lies on pipe 56418-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56418-2 at junction 86737 so both are connected.
Open
111ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86771
Junction 86771 (degree 1) lies on pipe 56395 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (19 m).
→ Split pipe 56395 at junction 86771 so both are connected.
Open
112ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86773
Junction 86773 (degree 2) lies on pipe 56395 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (21 m).
→ Split pipe 56395 at junction 86773 so both are connected.
Open
113ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86775
Junction 86775 (degree 2) lies on pipe 56395 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (22 m).
→ Split pipe 56395 at junction 86775 so both are connected.
Open
114ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86777
Junction 86777 (degree 1) lies on pipe 56395 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56395 at junction 86777 so both are connected.
Open
115ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86779
Junction 86779 (degree 1) lies on pipe 56395 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56395 at junction 86779 so both are connected.
Open
116ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86781
Junction 86781 (degree 1) lies on pipe 56395 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Split pipe 56395 at junction 86781 so both are connected.
Open
117ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86783
Junction 86783 (degree 2) lies on pipe 53501 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (18 m).
→ Split pipe 53501 at junction 86783 so both are connected.
Open
118ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86785
Junction 86785 (degree 1) lies on pipe 56395 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56395 at junction 86785 so both are connected.
Open
119ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86787
Junction 86787 (degree 1) lies on pipe 56395 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 56395 at junction 86787 so both are connected.
Open
120ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86789
Junction 86789 (degree 1) lies on pipe 56395 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56395 at junction 86789 so both are connected.
Open
121ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86793
Junction 86793 (degree 1) lies on pipe 56395 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 56395 at junction 86793 so both are connected.
Open
122ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86796
Junction 86796 (degree 1) lies on pipe 53501 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53501 at junction 86796 so both are connected.
Open
123ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86798
Junction 86798 (degree 2) lies on pipe 53501 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (17 m).
→ Split pipe 53501 at junction 86798 so both are connected.
Open
124ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86801
Junction 86801 (degree 1) lies on pipe 53501 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 53501 at junction 86801 so both are connected.
Open
125ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86803
Junction 86803 (degree 2) lies on pipe 53501 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (19 m).
→ Split pipe 53501 at junction 86803 so both are connected.
Open
126ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86805
Junction 86805 (degree 1) lies on pipe 53501 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 53501 at junction 86805 so both are connected.
Open
127ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86807
Junction 86807 (degree 1) lies on pipe 53501 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (26 m).
→ Split pipe 53501 at junction 86807 so both are connected.
Open
128ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86809
Junction 86809 (degree 2) lies on pipe 53501 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (37 m).
→ Split pipe 53501 at junction 86809 so both are connected.
Open
129ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86811
Junction 86811 (degree 2) lies on pipe 53502 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (20 m).
→ Split pipe 53502 at junction 86811 so both are connected.
Open
130ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86814
Junction 86814 (degree 1) lies on pipe 53501 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 53501 at junction 86814 so both are connected.
Open
131ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86818
Junction 86818 (degree 1) lies on pipe 53502 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53502 at junction 86818 so both are connected.
Open
132ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86820
Junction 86820 (degree 1) lies on pipe 53502 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 53502 at junction 86820 so both are connected.
Open
133ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86822
Junction 86822 (degree 1) lies on pipe 53502 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 53502 at junction 86822 so both are connected.
Open
134ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86824
Junction 86824 (degree 1) lies on pipe 52881 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52881 at junction 86824 so both are connected.
Open
135ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86826
Junction 86826 (degree 2) lies on pipe 52881 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (24 m).
→ Split pipe 52881 at junction 86826 so both are connected.
Open
136ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86829
Junction 86829 (degree 2) lies on pipe 52881 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (50 m).
→ Split pipe 52881 at junction 86829 so both are connected.
Open
137ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86832
Junction 86832 (degree 2) lies on pipe 52881 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (25 m).
→ Split pipe 52881 at junction 86832 so both are connected.
Open
138ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86835
Junction 86835 (degree 1) lies on pipe 52881 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 52881 at junction 86835 so both are connected.
Open
139ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86837
Junction 86837 (degree 1) lies on pipe 52881 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 52881 at junction 86837 so both are connected.
Open
140ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86839
Junction 86839 (degree 1) lies on pipe 52881 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52881 at junction 86839 so both are connected.
Open
141ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86841
Junction 86841 (degree 1) lies on pipe 52919 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 52919 at junction 86841 so both are connected.
Open
142ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86843
Junction 86843 (degree 1) lies on pipe 52919 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52919 at junction 86843 so both are connected.
Open
143ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86845
Junction 86845 (degree 1) lies on pipe 52919 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 52919 at junction 86845 so both are connected.
Open
144ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86847
Junction 86847 (degree 1) lies on pipe 52919 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52919 at junction 86847 so both are connected.
Open
145ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86849
Junction 86849 (degree 1) lies on pipe 52919 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52919 at junction 86849 so both are connected.
Open
146ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86851
Junction 86851 (degree 1) lies on pipe 52919 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (17 m).
→ Split pipe 52919 at junction 86851 so both are connected.
Open
147ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86853
Junction 86853 (degree 2) lies on pipe 52919 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (27 m).
→ Split pipe 52919 at junction 86853 so both are connected.
Open
148ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86856
Junction 86856 (degree 1) lies on pipe 52919 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52919 at junction 86856 so both are connected.
Open
149ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86858
Junction 86858 (degree 1) lies on pipe 52919 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (20 m).
→ Split pipe 52919 at junction 86858 so both are connected.
Open
150ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86859
Junction 86859 (degree 1) lies on pipe 52919 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (105 m).
→ Split pipe 52919 at junction 86859 so both are connected.
Open
151ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86862
Junction 86862 (degree 1) lies on pipe 52877 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52877 at junction 86862 so both are connected.
Open
152ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86864
Junction 86864 (degree 1) lies on pipe 52919 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (33 m).
→ Split pipe 52919 at junction 86864 so both are connected.
Open
153ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86868
Junction 86868 (degree 1) lies on pipe 52919 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52919 at junction 86868 so both are connected.
Open
154ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86873
Junction 86873 (degree 1) lies on pipe 52877 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52877 at junction 86873 so both are connected.
Open
155ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86875
Junction 86875 (degree 1) lies on pipe 56501-2 (DN 20, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56501-2 at junction 86875 so both are connected.
Open
156ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86877
Junction 86877 (degree 1) lies on pipe 52877 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52877 at junction 86877 so both are connected.
Open
157ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86879
Junction 86879 (degree 1) lies on pipe 56501-2 (DN 20, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56501-2 at junction 86879 so both are connected.
Open
158ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86881
Junction 86881 (degree 1) lies on pipe 52877 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52877 at junction 86881 so both are connected.
Open
159ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86883
Junction 86883 (degree 1) lies on pipe 56501-1 (DN 20, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56501-1 at junction 86883 so both are connected.
Open
160ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86885
Junction 86885 (degree 1) lies on pipe 52877 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 52877 at junction 86885 so both are connected.
Open
161ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86887
Junction 86887 (degree 1) lies on pipe 52878 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52878 at junction 86887 so both are connected.
Open
162ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86889
Junction 86889 (degree 1) lies on pipe 52877 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52877 at junction 86889 so both are connected.
Open
163ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86891
Junction 86891 (degree 1) lies on pipe 52878 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 52878 at junction 86891 so both are connected.
Open
164ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86893
Junction 86893 (degree 1) lies on pipe 52877 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 52877 at junction 86893 so both are connected.
Open
165ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86895
Junction 86895 (degree 1) lies on pipe 52878 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52878 at junction 86895 so both are connected.
Open
166ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86897
Junction 86897 (degree 1) lies on pipe 52878 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52878 at junction 86897 so both are connected.
Open
167ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86899
Junction 86899 (degree 1) lies on pipe 52878 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52878 at junction 86899 so both are connected.
Open
168ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86901
Junction 86901 (degree 1) lies on pipe 52878 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52878 at junction 86901 so both are connected.
Open
169ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86903
Junction 86903 (degree 1) lies on pipe 52878 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52878 at junction 86903 so both are connected.
Open
170ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86905
Junction 86905 (degree 1) lies on pipe 52878 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52878 at junction 86905 so both are connected.
Open
171ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86907
Junction 86907 (degree 1) lies on pipe 56502 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56502 at junction 86907 so both are connected.
Open
172ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86909
Junction 86909 (degree 1) lies on pipe 52877 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52877 at junction 86909 so both are connected.
Open
173ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86911
Junction 86911 (degree 1) lies on pipe 52877 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52877 at junction 86911 so both are connected.
Open
174ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86913
Junction 86913 (degree 1) lies on pipe 52877 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52877 at junction 86913 so both are connected.
Open
175ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86915
Junction 86915 (degree 1) lies on pipe 52877 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52877 at junction 86915 so both are connected.
Open
176ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86917
Junction 86917 (degree 1) lies on pipe 52877 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52877 at junction 86917 so both are connected.
Open
177ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86919
Junction 86919 (degree 1) lies on pipe 52877 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52877 at junction 86919 so both are connected.
Open
178ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86921
Junction 86921 (degree 1) lies on pipe 52899 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 52899 at junction 86921 so both are connected.
Open
179ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86923
Junction 86923 (degree 1) lies on pipe 56500 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 56500 at junction 86923 so both are connected.
Open
180ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86925
Junction 86925 (degree 1) lies on pipe 56500 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Split pipe 56500 at junction 86925 so both are connected.
Open
181ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86927
Junction 86927 (degree 1) lies on pipe 53731 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 53731 at junction 86927 so both are connected.
Open
182ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86929
Junction 86929 (degree 1) lies on pipe 53731 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (21 m).
→ Split pipe 53731 at junction 86929 so both are connected.
Open
183ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86931
Junction 86931 (degree 2) lies on pipe 53731 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (25 m).
→ Split pipe 53731 at junction 86931 so both are connected.
Open
184ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86934
Junction 86934 (degree 2) lies on pipe 53731 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (24 m).
→ Split pipe 53731 at junction 86934 so both are connected.
Open
185ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86937
Junction 86937 (degree 1) lies on pipe 53731 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53731 at junction 86937 so both are connected.
Open
186ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86939
Junction 86939 (degree 1) lies on pipe 53731 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53731 at junction 86939 so both are connected.
Open
187ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86941
Junction 86941 (degree 1) lies on pipe 53731 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (19 m).
→ Split pipe 53731 at junction 86941 so both are connected.
Open
188ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86943
Junction 86943 (degree 1) lies on pipe 53731 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 53731 at junction 86943 so both are connected.
Open
189ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86945
Junction 86945 (degree 1) lies on pipe 53731 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 53731 at junction 86945 so both are connected.
Open
190ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86947
Junction 86947 (degree 1) lies on pipe 53731 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53731 at junction 86947 so both are connected.
Open
191ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86949
Junction 86949 (degree 2) lies on pipe 53731 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (21 m).
→ Split pipe 53731 at junction 86949 so both are connected.
Open
192ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86951
Junction 86951 (degree 2) lies on pipe 53731 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (18 m).
→ Split pipe 53731 at junction 86951 so both are connected.
Open
193ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86953
Junction 86953 (degree 1) lies on pipe 53730-2 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 53730-2 at junction 86953 so both are connected.
Open
194ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86958
Junction 86958 (degree 1) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53730-1 at junction 86958 so both are connected.
Open
195ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86962
Junction 86962 (degree 2) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (22 m).
→ Split pipe 53730-1 at junction 86962 so both are connected.
Open
196ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86965
Junction 86965 (degree 2) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (19 m).
→ Split pipe 53730-1 at junction 86965 so both are connected.
Open
197ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86968
Junction 86968 (degree 1) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 53730-1 at junction 86968 so both are connected.
Open
198ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86970
Junction 86970 (degree 1) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 53730-1 at junction 86970 so both are connected.
Open
199ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86972
Junction 86972 (degree 1) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 53730-1 at junction 86972 so both are connected.
Open
200ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86974
Junction 86974 (degree 1) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53730-1 at junction 86974 so both are connected.
Open
201ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86976
Junction 86976 (degree 2) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (23 m).
→ Split pipe 53730-1 at junction 86976 so both are connected.
Open
202ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86978
Junction 86978 (degree 1) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53730-1 at junction 86978 so both are connected.
Open
203ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86980
Junction 86980 (degree 1) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 53730-1 at junction 86980 so both are connected.
Open
204ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86983
Junction 86983 (degree 1) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 53730-1 at junction 86983 so both are connected.
Open
205ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86985
Junction 86985 (degree 1) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53730-1 at junction 86985 so both are connected.
Open
206ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86987
Junction 86987 (degree 2) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (21 m).
→ Split pipe 53730-1 at junction 86987 so both are connected.
Open
207ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86989
Junction 86989 (degree 1) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53730-1 at junction 86989 so both are connected.
Open
208ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86992
Junction 86992 (degree 2) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (19 m).
→ Split pipe 53730-1 at junction 86992 so both are connected.
Open
209ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86994
Junction 86994 (degree 1) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53730-1 at junction 86994 so both are connected.
Open
210ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86996
Junction 86996 (degree 1) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 53730-1 at junction 86996 so both are connected.
Open
211ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86998
Junction 86998 (degree 1) lies on pipe 53704 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Split pipe 53704 at junction 86998 so both are connected.
Open
212ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87000
Junction 87000 (degree 1) lies on pipe 53704 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 53704 at junction 87000 so both are connected.
Open
213ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87002
Junction 87002 (degree 1) lies on pipe 53704 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Split pipe 53704 at junction 87002 so both are connected.
Open
214ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87005
Junction 87005 (degree 1) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53730-1 at junction 87005 so both are connected.
Open
215ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87007
Junction 87007 (degree 1) lies on pipe 53703-1 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 53703-1 at junction 87007 so both are connected.
Open
216ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87009
Junction 87009 (degree 2) lies on pipe 53703-1 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (21 m).
→ Split pipe 53703-1 at junction 87009 so both are connected.
Open
217ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87011
Junction 87011 (degree 1) lies on pipe 53703-1 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 53703-1 at junction 87011 so both are connected.
Open
218ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87013
Junction 87013 (degree 1) lies on pipe 53703-1 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (23 m).
→ Split pipe 53703-1 at junction 87013 so both are connected.
Open
219ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87015
Junction 87015 (degree 1) lies on pipe 53703-1 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53703-1 at junction 87015 so both are connected.
Open
220ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87017
Junction 87017 (degree 1) lies on pipe 53703-1 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 53703-1 at junction 87017 so both are connected.
Open
221ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87021
Junction 87021 (degree 1) lies on pipe 53705 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (22 m).
→ Split pipe 53705 at junction 87021 so both are connected.
Open
222ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87023
Junction 87023 (degree 1) lies on pipe 53705 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 53705 at junction 87023 so both are connected.
Open
223ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87025
Junction 87025 (degree 1) lies on pipe 53704 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53704 at junction 87025 so both are connected.
Open
224ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87027
Junction 87027 (degree 1) lies on pipe 53704 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 53704 at junction 87027 so both are connected.
Open
225ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87029
Junction 87029 (degree 1) lies on pipe 53704 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53704 at junction 87029 so both are connected.
Open
226ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87031
Junction 87031 (degree 1) lies on pipe 53704 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 53704 at junction 87031 so both are connected.
Open
227ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87033
Junction 87033 (degree 1) lies on pipe 53704 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 53704 at junction 87033 so both are connected.
Open
228ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87035
Junction 87035 (degree 1) lies on pipe 53508 (DN 50, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 53508 at junction 87035 so both are connected.
Open
229ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87037
Junction 87037 (degree 1) lies on pipe 53508 (DN 50, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 53508 at junction 87037 so both are connected.
Open
230ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87039
Junction 87039 (degree 1) lies on pipe 53508 (DN 50, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 53508 at junction 87039 so both are connected.
Open
231ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87041
Junction 87041 (degree 1) lies on pipe 53508 (DN 50, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53508 at junction 87041 so both are connected.
Open
232ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87043
Junction 87043 (degree 1) lies on pipe 53508 (DN 50, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53508 at junction 87043 so both are connected.
Open
233ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87045
Junction 87045 (degree 1) lies on pipe 53508 (DN 50, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53508 at junction 87045 so both are connected.
Open
234ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87047
Junction 87047 (degree 1) lies on pipe 53508 (DN 50, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 53508 at junction 87047 so both are connected.
Open
235ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87075
Junction 87075 (degree 1) lies on pipe 56430 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56430 at junction 87075 so both are connected.
Open
236ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87077
Junction 87077 (degree 2) lies on pipe 56430 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (14 m).
→ Split pipe 56430 at junction 87077 so both are connected.
Open
237ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87079
Junction 87079 (degree 1) lies on pipe 56430 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 56430 at junction 87079 so both are connected.
Open
238ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87081
Junction 87081 (degree 1) lies on pipe 56430 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56430 at junction 87081 so both are connected.
Open
239ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87084
Junction 87084 (degree 1) lies on pipe 56430 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56430 at junction 87084 so both are connected.
Open
240ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87086
Junction 87086 (degree 1) lies on pipe 56430 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56430 at junction 87086 so both are connected.
Open
241ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87088
Junction 87088 (degree 1) lies on pipe 56430 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (25 m).
→ Split pipe 56430 at junction 87088 so both are connected.
Open
242ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87092
Junction 87092 (degree 1) lies on pipe 56430 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56430 at junction 87092 so both are connected.
Open
243ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8716
Junction 8716 (degree 1) lies on pipe 89497-1 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 89497-1 at junction 8716 so both are connected.
Open
244ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8718
Junction 8718 (degree 1) lies on pipe 89497-1 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 89497-1 at junction 8718 so both are connected.
Open
245ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8719
Junction 8719 (degree 1) lies on pipe 89497-1 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 89497-1 at junction 8719 so both are connected.
Open
246ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8720
Junction 8720 (degree 1) lies on pipe 89497-1 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 89497-1 at junction 8720 so both are connected.
Open
247ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8725
Junction 8725 (degree 1) lies on pipe 89497-2 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 89497-2 at junction 8725 so both are connected.
Open
248ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8728
Junction 8728 (degree 1) lies on pipe 52908-2 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 16 pipe(s) (261 m).
→ Split pipe 52908-2 at junction 8728 so both are connected.
Open
249ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87324
Junction 87324 (degree 1) lies on pipe 56526-1 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56526-1 at junction 87324 so both are connected.
Open
250ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87330
Junction 87330 (degree 1) lies on pipe 56526-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56526-2 at junction 87330 so both are connected.
Open
251ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87332
Junction 87332 (degree 1) lies on pipe 56526-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56526-2 at junction 87332 so both are connected.
Open
252ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87334
Junction 87334 (degree 1) lies on pipe 56526-3 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56526-3 at junction 87334 so both are connected.
Open
253ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87336
Junction 87336 (degree 1) lies on pipe 56526-3 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56526-3 at junction 87336 so both are connected.
Open
254ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87338
Junction 87338 (degree 1) lies on pipe 56526-3 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56526-3 at junction 87338 so both are connected.
Open
255ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87340
Junction 87340 (degree 1) lies on pipe 56526-3 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56526-3 at junction 87340 so both are connected.
Open
256ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87342
Junction 87342 (degree 1) lies on pipe 56526-3 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56526-3 at junction 87342 so both are connected.
Open
257ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87344
Junction 87344 (degree 1) lies on pipe 56526-3 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56526-3 at junction 87344 so both are connected.
Open
258ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87476
Junction 87476 (degree 1) lies on pipe 56419-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56419-2 at junction 87476 so both are connected.
Open
259ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87484
Junction 87484 (degree 1) lies on pipe 56419-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56419-2 at junction 87484 so both are connected.
Open
260ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87486
Junction 87486 (degree 1) lies on pipe 56419-1 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56419-1 at junction 87486 so both are connected.
Open
261ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87713
Junction 87713 (degree 2) lies on pipe 56412 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (22 m).
→ Split pipe 56412 at junction 87713 so both are connected.
Open
262ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87715
Junction 87715 (degree 1) lies on pipe 56453 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 56453 at junction 87715 so both are connected.
Open
263ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87717
Junction 87717 (degree 1) lies on pipe 56453 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 56453 at junction 87717 so both are connected.
Open
264ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87719
Junction 87719 (degree 2) lies on pipe 56447 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (29 m).
→ Split pipe 56447 at junction 87719 so both are connected.
Open
265ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87721
Junction 87721 (degree 1) lies on pipe 56448 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (22 m).
→ Split pipe 56448 at junction 87721 so both are connected.
Open
266ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87723
Junction 87723 (degree 1) lies on pipe 56428 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56428 at junction 87723 so both are connected.
Open
267ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87725
Junction 87725 (degree 1) lies on pipe 56453 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56453 at junction 87725 so both are connected.
Open
268ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87727
Junction 87727 (degree 1) lies on pipe 56453 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56453 at junction 87727 so both are connected.
Open
269ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87729
Junction 87729 (degree 1) lies on pipe 56453 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56453 at junction 87729 so both are connected.
Open
270ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87731
Junction 87731 (degree 2) lies on pipe 56466 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (38 m).
→ Split pipe 56466 at junction 87731 so both are connected.
Open
271ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87733
Junction 87733 (degree 1) lies on pipe 56465 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56465 at junction 87733 so both are connected.
Open
272ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87735
Junction 87735 (degree 1) lies on pipe 56465 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56465 at junction 87735 so both are connected.
Open
273ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87739
Junction 87739 (degree 1) lies on pipe 56411 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56411 at junction 87739 so both are connected.
Open
274ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87741
Junction 87741 (degree 2) lies on pipe 56407-1 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (23 m).
→ Split pipe 56407-1 at junction 87741 so both are connected.
Open
275ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87743
Junction 87743 (degree 2) lies on pipe 56413 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (20 m).
→ Split pipe 56413 at junction 87743 so both are connected.
Open
276ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87745
Junction 87745 (degree 1) lies on pipe 56411 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56411 at junction 87745 so both are connected.
Open
277ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87747
Junction 87747 (degree 1) lies on pipe 56407-2 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 56407-2 at junction 87747 so both are connected.
Open
278ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87749
Junction 87749 (degree 1) lies on pipe 56411 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (30 m).
→ Split pipe 56411 at junction 87749 so both are connected.
Open
279ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87751
Junction 87751 (degree 1) lies on pipe 56412 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 56412 at junction 87751 so both are connected.
Open
280ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87753
Junction 87753 (degree 1) lies on pipe 56412 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (17 m).
→ Split pipe 56412 at junction 87753 so both are connected.
Open
281ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87759
Junction 87759 (degree 1) lies on pipe 56412 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (19 m).
→ Split pipe 56412 at junction 87759 so both are connected.
Open
282ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87761
Junction 87761 (degree 2) lies on pipe 56412 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (24 m).
→ Split pipe 56412 at junction 87761 so both are connected.
Open
283ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87764
Junction 87764 (degree 1) lies on pipe 56413 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56413 at junction 87764 so both are connected.
Open
284ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87766
Junction 87766 (degree 2) lies on pipe 56412 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (29 m).
→ Split pipe 56412 at junction 87766 so both are connected.
Open
285ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87768
Junction 87768 (degree 1) lies on pipe 56412 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 56412 at junction 87768 so both are connected.
Open
286ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87770
Junction 87770 (degree 2) lies on pipe 56412 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (18 m).
→ Split pipe 56412 at junction 87770 so both are connected.
Open
287ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87772
Junction 87772 (degree 1) lies on pipe 56406 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (19 m).
→ Split pipe 56406 at junction 87772 so both are connected.
Open
288ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87774
Junction 87774 (degree 1) lies on pipe 56412 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56412 at junction 87774 so both are connected.
Open
289ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87776
Junction 87776 (degree 1) lies on pipe 56399-2 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (20 m).
→ Split pipe 56399-2 at junction 87776 so both are connected.
Open
290ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87778
Junction 87778 (degree 2) lies on pipe 56399-2 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (32 m).
→ Split pipe 56399-2 at junction 87778 so both are connected.
Open
291ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87780
Junction 87780 (degree 1) lies on pipe 56412 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56412 at junction 87780 so both are connected.
Open
292ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87784
Junction 87784 (degree 1) lies on pipe 56412 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56412 at junction 87784 so both are connected.
Open
293ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87788
Junction 87788 (degree 1) lies on pipe 56412 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 56412 at junction 87788 so both are connected.
Open
294ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87790
Junction 87790 (degree 1) lies on pipe 56399-2 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (20 m).
→ Split pipe 56399-2 at junction 87790 so both are connected.
Open
295ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87792
Junction 87792 (degree 2) lies on pipe 56399-2 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (23 m).
→ Split pipe 56399-2 at junction 87792 so both are connected.
Open
296ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87794
Junction 87794 (degree 2) lies on pipe 56399-2 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (24 m).
→ Split pipe 56399-2 at junction 87794 so both are connected.
Open
297ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87796
Junction 87796 (degree 2) lies on pipe 56399-2 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (26 m).
→ Split pipe 56399-2 at junction 87796 so both are connected.
Open
298ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87798
Junction 87798 (degree 1) lies on pipe 56399-2 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (24 m).
→ Split pipe 56399-2 at junction 87798 so both are connected.
Open
299ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87802
Junction 87802 (degree 2) lies on pipe 56399-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (33 m).
→ Split pipe 56399-1 at junction 87802 so both are connected.
Open
300ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87811
Junction 87811 (degree 1) lies on pipe 56399-2 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56399-2 at junction 87811 so both are connected.
Open
301ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87814
Junction 87814 (degree 1) lies on pipe 56399-2 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (22 m).
→ Split pipe 56399-2 at junction 87814 so both are connected.
Open
302ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87816
Junction 87816 (degree 1) lies on pipe 56399-2 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (20 m).
→ Split pipe 56399-2 at junction 87816 so both are connected.
Open
303ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87820
Junction 87820 (degree 1) lies on pipe 56399-2 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56399-2 at junction 87820 so both are connected.
Open
304ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87823
Junction 87823 (degree 1) lies on pipe 56397 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56397 at junction 87823 so both are connected.
Open
305ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87825
Junction 87825 (degree 1) lies on pipe 56397 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56397 at junction 87825 so both are connected.
Open
306ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87859
Junction 87859 (degree 1) lies on pipe 52882-1 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52882-1 at junction 87859 so both are connected.
Open
307ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87861
Junction 87861 (degree 1) lies on pipe 52882-1 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52882-1 at junction 87861 so both are connected.
Open
308ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87863
Junction 87863 (degree 1) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52882-2 at junction 87863 so both are connected.
Open
309ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87865
Junction 87865 (degree 1) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52882-2 at junction 87865 so both are connected.
Open
310ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87867
Junction 87867 (degree 2) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (17 m).
→ Split pipe 52882-2 at junction 87867 so both are connected.
Open
311ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87871
Junction 87871 (degree 1) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52882-2 at junction 87871 so both are connected.
Open
312ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87874
Junction 87874 (degree 1) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 52882-2 at junction 87874 so both are connected.
Open
313ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87876
Junction 87876 (degree 1) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 52882-2 at junction 87876 so both are connected.
Open
314ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87878
Junction 87878 (degree 1) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52882-2 at junction 87878 so both are connected.
Open
315ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87880
Junction 87880 (degree 1) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52882-2 at junction 87880 so both are connected.
Open
316ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87882
Junction 87882 (degree 1) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52882-2 at junction 87882 so both are connected.
Open
317ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87884
Junction 87884 (degree 2) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (19 m).
→ Split pipe 52882-2 at junction 87884 so both are connected.
Open
318ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87886
Junction 87886 (degree 2) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (19 m).
→ Split pipe 52882-2 at junction 87886 so both are connected.
Open
319ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87889
Junction 87889 (degree 1) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52882-2 at junction 87889 so both are connected.
Open
320ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87892
Junction 87892 (degree 1) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52882-2 at junction 87892 so both are connected.
Open
321ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87894
Junction 87894 (degree 1) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52882-2 at junction 87894 so both are connected.
Open
322ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87896
Junction 87896 (degree 1) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52882-2 at junction 87896 so both are connected.
Open
323ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87898
Junction 87898 (degree 1) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52882-2 at junction 87898 so both are connected.
Open
324ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87900
Junction 87900 (degree 2) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (17 m).
→ Split pipe 52882-2 at junction 87900 so both are connected.
Open
325ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87902
Junction 87902 (degree 2) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (17 m).
→ Split pipe 52882-2 at junction 87902 so both are connected.
Open
326ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87904
Junction 87904 (degree 1) lies on pipe 52882-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52882-2 at junction 87904 so both are connected.
Open
327ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87908
Junction 87908 (degree 1) lies on pipe 52883 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52883 at junction 87908 so both are connected.
Open
328ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87910
Junction 87910 (degree 1) lies on pipe 52883 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52883 at junction 87910 so both are connected.
Open
329ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87912
Junction 87912 (degree 1) lies on pipe 52883 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Split pipe 52883 at junction 87912 so both are connected.
Open
330ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87914
Junction 87914 (degree 1) lies on pipe 52884 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52884 at junction 87914 so both are connected.
Open
331ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87916
Junction 87916 (degree 1) lies on pipe 52884 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52884 at junction 87916 so both are connected.
Open
332ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87918
Junction 87918 (degree 1) lies on pipe 52884 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52884 at junction 87918 so both are connected.
Open
333ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87920
Junction 87920 (degree 1) lies on pipe 52884 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52884 at junction 87920 so both are connected.
Open
334ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87922
Junction 87922 (degree 1) lies on pipe 52884 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52884 at junction 87922 so both are connected.
Open
335ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87924
Junction 87924 (degree 2) lies on pipe 52879 (DN 125, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (18 m).
→ Split pipe 52879 at junction 87924 so both are connected.
Open
336ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87926
Junction 87926 (degree 2) lies on pipe 52879 (DN 125, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (20 m).
→ Split pipe 52879 at junction 87926 so both are connected.
Open
337ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87928
Junction 87928 (degree 1) lies on pipe 52879 (DN 125, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 52879 at junction 87928 so both are connected.
Open
338ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87940
Junction 87940 (degree 1) lies on pipe 52885 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52885 at junction 87940 so both are connected.
Open
339ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87942
Junction 87942 (degree 1) lies on pipe 52885 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52885 at junction 87942 so both are connected.
Open
340ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87944
Junction 87944 (degree 1) lies on pipe 52885 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52885 at junction 87944 so both are connected.
Open
341ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87948
Junction 87948 (degree 2) lies on pipe 52886-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (12 m).
→ Split pipe 52886-2 at junction 87948 so both are connected.
Open
342ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87950
Junction 87950 (degree 2) lies on pipe 52886-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (15 m).
→ Split pipe 52886-2 at junction 87950 so both are connected.
Open
343ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87952
Junction 87952 (degree 2) lies on pipe 52886-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (14 m).
→ Split pipe 52886-2 at junction 87952 so both are connected.
Open
344ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87954
Junction 87954 (degree 1) lies on pipe 52886-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52886-2 at junction 87954 so both are connected.
Open
345ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87956
Junction 87956 (degree 1) lies on pipe 52886-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52886-2 at junction 87956 so both are connected.
Open
346ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87958
Junction 87958 (degree 1) lies on pipe 52887 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 52887 at junction 87958 so both are connected.
Open
347ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87960
Junction 87960 (degree 2) lies on pipe 52887 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (16 m).
→ Split pipe 52887 at junction 87960 so both are connected.
Open
348ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87962
Junction 87962 (degree 1) lies on pipe 52887 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52887 at junction 87962 so both are connected.
Open
349ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87964
Junction 87964 (degree 1) lies on pipe 52887 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52887 at junction 87964 so both are connected.
Open
350ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87980
Junction 87980 (degree 1) lies on pipe 52885 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52885 at junction 87980 so both are connected.
Open
351ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87982
Junction 87982 (degree 1) lies on pipe 52885 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52885 at junction 87982 so both are connected.
Open
352ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87984
Junction 87984 (degree 1) lies on pipe 52886-1 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52886-1 at junction 87984 so both are connected.
Open
353ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87986
Junction 87986 (degree 1) lies on pipe 52886-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52886-2 at junction 87986 so both are connected.
Open
354ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87990
Junction 87990 (degree 1) lies on pipe 52886-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52886-2 at junction 87990 so both are connected.
Open
355ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87993
Junction 87993 (degree 1) lies on pipe 52886-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52886-2 at junction 87993 so both are connected.
Open
356ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87995
Junction 87995 (degree 1) lies on pipe 52887 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52887 at junction 87995 so both are connected.
Open
357ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87997
Junction 87997 (degree 1) lies on pipe 52887 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 52887 at junction 87997 so both are connected.
Open
358ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87999
Junction 87999 (degree 1) lies on pipe 52887 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 52887 at junction 87999 so both are connected.
Open
359ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88001
Junction 88001 (degree 1) lies on pipe 52887 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52887 at junction 88001 so both are connected.
Open
360ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88003
Junction 88003 (degree 1) lies on pipe 52887 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52887 at junction 88003 so both are connected.
Open
361ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88006
Junction 88006 (degree 1) lies on pipe 52887 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52887 at junction 88006 so both are connected.
Open
362ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88008
Junction 88008 (degree 1) lies on pipe 52887 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52887 at junction 88008 so both are connected.
Open
363ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88012
Junction 88012 (degree 2) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (24 m).
→ Split pipe 56492 at junction 88012 so both are connected.
Open
364ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88015
Junction 88015 (degree 1) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 56492 at junction 88015 so both are connected.
Open
365ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88017
Junction 88017 (degree 1) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56492 at junction 88017 so both are connected.
Open
366ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88019
Junction 88019 (degree 1) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56492 at junction 88019 so both are connected.
Open
367ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88021
Junction 88021 (degree 1) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56492 at junction 88021 so both are connected.
Open
368ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88023
Junction 88023 (degree 2) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (19 m).
→ Split pipe 56492 at junction 88023 so both are connected.
Open
369ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88026
Junction 88026 (degree 2) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (18 m).
→ Split pipe 56492 at junction 88026 so both are connected.
Open
370ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88029
Junction 88029 (degree 1) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56492 at junction 88029 so both are connected.
Open
371ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88031
Junction 88031 (degree 1) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56492 at junction 88031 so both are connected.
Open
372ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88033
Junction 88033 (degree 1) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56492 at junction 88033 so both are connected.
Open
373ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88035
Junction 88035 (degree 1) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56492 at junction 88035 so both are connected.
Open
374ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88037
Junction 88037 (degree 1) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56492 at junction 88037 so both are connected.
Open
375ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88039
Junction 88039 (degree 1) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56492 at junction 88039 so both are connected.
Open
376ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88041
Junction 88041 (degree 1) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56492 at junction 88041 so both are connected.
Open
377ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88043
Junction 88043 (degree 1) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 56492 at junction 88043 so both are connected.
Open
378ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88045
Junction 88045 (degree 1) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56492 at junction 88045 so both are connected.
Open
379ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88047
Junction 88047 (degree 1) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56492 at junction 88047 so both are connected.
Open
380ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88051
Junction 88051 (degree 1) lies on pipe 53728 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 53728 at junction 88051 so both are connected.
Open
381ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88053
Junction 88053 (degree 2) lies on pipe 53728 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (19 m).
→ Split pipe 53728 at junction 88053 so both are connected.
Open
382ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88055
Junction 88055 (degree 1) lies on pipe 53728 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53728 at junction 88055 so both are connected.
Open
383ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88057
Junction 88057 (degree 1) lies on pipe 53728 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53728 at junction 88057 so both are connected.
Open
384ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88059
Junction 88059 (degree 1) lies on pipe 53728 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 53728 at junction 88059 so both are connected.
Open
385ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88061
Junction 88061 (degree 1) lies on pipe 53728 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 53728 at junction 88061 so both are connected.
Open
386ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88063
Junction 88063 (degree 1) lies on pipe 53728 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 53728 at junction 88063 so both are connected.
Open
387ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88065
Junction 88065 (degree 1) lies on pipe 53728 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 53728 at junction 88065 so both are connected.
Open
388ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88067
Junction 88067 (degree 1) lies on pipe 53728 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 53728 at junction 88067 so both are connected.
Open
389ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88069
Junction 88069 (degree 1) lies on pipe 53728 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 53728 at junction 88069 so both are connected.
Open
390ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88071
Junction 88071 (degree 1) lies on pipe 53728 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 53728 at junction 88071 so both are connected.
Open
391ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88074
Junction 88074 (degree 1) lies on pipe 53728 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53728 at junction 88074 so both are connected.
Open
392ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88076
Junction 88076 (degree 1) lies on pipe 52899 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52899 at junction 88076 so both are connected.
Open
393ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88078
Junction 88078 (degree 1) lies on pipe 52899 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 52899 at junction 88078 so both are connected.
Open
394ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88080
Junction 88080 (degree 1) lies on pipe 52899 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52899 at junction 88080 so both are connected.
Open
395ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88082
Junction 88082 (degree 1) lies on pipe 52899 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52899 at junction 88082 so both are connected.
Open
396ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88084
Junction 88084 (degree 1) lies on pipe 52899 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52899 at junction 88084 so both are connected.
Open
397ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88086
Junction 88086 (degree 1) lies on pipe 52899 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 52899 at junction 88086 so both are connected.
Open
398ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88088
Junction 88088 (degree 1) lies on pipe 52899 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 52899 at junction 88088 so both are connected.
Open
399ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88090
Junction 88090 (degree 1) lies on pipe 52889 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 52889 at junction 88090 so both are connected.
Open
400ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88092
Junction 88092 (degree 1) lies on pipe 52910-4 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 52910-4 at junction 88092 so both are connected.
Open
401ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88094
Junction 88094 (degree 1) lies on pipe 52889 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 52889 at junction 88094 so both are connected.
Open
402ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88098
Junction 88098 (degree 1) lies on pipe 52899 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52899 at junction 88098 so both are connected.
Open
403ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88100
Junction 88100 (degree 1) lies on pipe 52899 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52899 at junction 88100 so both are connected.
Open
404ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88102
Junction 88102 (degree 1) lies on pipe 52899 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52899 at junction 88102 so both are connected.
Open
405ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88104
Junction 88104 (degree 1) lies on pipe 52899 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52899 at junction 88104 so both are connected.
Open
406ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88106
Junction 88106 (degree 1) lies on pipe 52899 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52899 at junction 88106 so both are connected.
Open
407ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88108
Junction 88108 (degree 1) lies on pipe 52889 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52889 at junction 88108 so both are connected.
Open
408ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88110
Junction 88110 (degree 1) lies on pipe 52910-4 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52910-4 at junction 88110 so both are connected.
Open
409ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88112
Junction 88112 (degree 1) lies on pipe 52910-3 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 52910-3 at junction 88112 so both are connected.
Open
410ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88114
Junction 88114 (degree 1) lies on pipe 89616 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 89616 at junction 88114 so both are connected.
Open
411ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88116
Junction 88116 (degree 1) lies on pipe 89616 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 89616 at junction 88116 so both are connected.
Open
412ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88118
Junction 88118 (degree 1) lies on pipe 89616 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 89616 at junction 88118 so both are connected.
Open
413ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88120
Junction 88120 (degree 1) lies on pipe 89616 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 89616 at junction 88120 so both are connected.
Open
414ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88165
Junction 88165 (degree 1) lies on pipe 52978-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52978-2 at junction 88165 so both are connected.
Open
415ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88167
Junction 88167 (degree 1) lies on pipe 52978-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52978-2 at junction 88167 so both are connected.
Open
416ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88170
Junction 88170 (degree 1) lies on pipe 52978-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52978-2 at junction 88170 so both are connected.
Open
417ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88171
Junction 88171 (degree 1) lies on pipe 52978-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52978-2 at junction 88171 so both are connected.
Open
418ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88174
Junction 88174 (degree 1) lies on pipe 52978-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 52978-2 at junction 88174 so both are connected.
Open
419ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88176
Junction 88176 (degree 1) lies on pipe 56468-1 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56468-1 at junction 88176 so both are connected.
Open
420ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88178
Junction 88178 (degree 1) lies on pipe 56468-1 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56468-1 at junction 88178 so both are connected.
Open
421ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8818
Junction 8818 (degree 1) lies on pipe 89522-1 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 89522-1 at junction 8818 so both are connected.
Open
422ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88180
Junction 88180 (degree 1) lies on pipe 56468-1 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56468-1 at junction 88180 so both are connected.
Open
423ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88184
Junction 88184 (degree 2) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (17 m).
→ Split pipe 56468-2 at junction 88184 so both are connected.
Open
424ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88186
Junction 88186 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56468-2 at junction 88186 so both are connected.
Open
425ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88188
Junction 88188 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56468-2 at junction 88188 so both are connected.
Open
426ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88190
Junction 88190 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56468-2 at junction 88190 so both are connected.
Open
427ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88192
Junction 88192 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56468-2 at junction 88192 so both are connected.
Open
428ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88194
Junction 88194 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56468-2 at junction 88194 so both are connected.
Open
429ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88196
Junction 88196 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56468-2 at junction 88196 so both are connected.
Open
430ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88198
Junction 88198 (degree 2) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (13 m).
→ Split pipe 56468-2 at junction 88198 so both are connected.
Open
431ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88200
Junction 88200 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56468-2 at junction 88200 so both are connected.
Open
432ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88202
Junction 88202 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56468-2 at junction 88202 so both are connected.
Open
433ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88204
Junction 88204 (degree 2) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (13 m).
→ Split pipe 56468-2 at junction 88204 so both are connected.
Open
434ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88206
Junction 88206 (degree 2) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (13 m).
→ Split pipe 56468-2 at junction 88206 so both are connected.
Open
435ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88208
Junction 88208 (degree 2) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (16 m).
→ Split pipe 56468-2 at junction 88208 so both are connected.
Open
436ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8821
Junction 8821 (degree 1) lies on pipe 89522-1 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 89522-1 at junction 8821 so both are connected.
Open
437ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88210
Junction 88210 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56468-2 at junction 88210 so both are connected.
Open
438ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88213
Junction 88213 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56468-2 at junction 88213 so both are connected.
Open
439ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88215
Junction 88215 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56468-2 at junction 88215 so both are connected.
Open
440ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88217
Junction 88217 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56468-2 at junction 88217 so both are connected.
Open
441ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88219
Junction 88219 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56468-2 at junction 88219 so both are connected.
Open
442ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8822
Junction 8822 (degree 1) lies on pipe 89522-1 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 89522-1 at junction 8822 so both are connected.
Open
443ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88222
Junction 88222 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56468-2 at junction 88222 so both are connected.
Open
444ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88224
Junction 88224 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56468-2 at junction 88224 so both are connected.
Open
445ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88229
Junction 88229 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56468-2 at junction 88229 so both are connected.
Open
446ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8823
Junction 8823 (degree 1) lies on pipe 89522-1 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 89522-1 at junction 8823 so both are connected.
Open
447ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88231
Junction 88231 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56468-2 at junction 88231 so both are connected.
Open
448ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88233
Junction 88233 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56468-2 at junction 88233 so both are connected.
Open
449ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88235
Junction 88235 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56468-2 at junction 88235 so both are connected.
Open
450ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88237
Junction 88237 (degree 2) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (13 m).
→ Split pipe 56468-2 at junction 88237 so both are connected.
Open
451ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88239
Junction 88239 (degree 2) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (15 m).
→ Split pipe 56468-2 at junction 88239 so both are connected.
Open
452ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8824
Junction 8824 (degree 1) lies on pipe 89522-1 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 89522-1 at junction 8824 so both are connected.
Open
453ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88241
Junction 88241 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56468-2 at junction 88241 so both are connected.
Open
454ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88243
Junction 88243 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56468-2 at junction 88243 so both are connected.
Open
455ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88245
Junction 88245 (degree 2) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (21 m).
→ Split pipe 56468-2 at junction 88245 so both are connected.
Open
456ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88247
Junction 88247 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56468-2 at junction 88247 so both are connected.
Open
457ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88249
Junction 88249 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56468-2 at junction 88249 so both are connected.
Open
458ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8825
Junction 8825 (degree 1) lies on pipe 89522-1 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 89522-1 at junction 8825 so both are connected.
Open
459ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88251
Junction 88251 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56468-2 at junction 88251 so both are connected.
Open
460ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88253
Junction 88253 (degree 2) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (16 m).
→ Split pipe 56468-2 at junction 88253 so both are connected.
Open
461ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88255
Junction 88255 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56468-2 at junction 88255 so both are connected.
Open
462ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88257
Junction 88257 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56468-2 at junction 88257 so both are connected.
Open
463ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88259
Junction 88259 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56468-2 at junction 88259 so both are connected.
Open
464ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8826
Junction 8826 (degree 1) lies on pipe 89522-1 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 89522-1 at junction 8826 so both are connected.
Open
465ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88261
Junction 88261 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56468-2 at junction 88261 so both are connected.
Open
466ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88263
Junction 88263 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56468-2 at junction 88263 so both are connected.
Open
467ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88266
Junction 88266 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56468-2 at junction 88266 so both are connected.
Open
468ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88268
Junction 88268 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56468-2 at junction 88268 so both are connected.
Open
469ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88270
Junction 88270 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56468-2 at junction 88270 so both are connected.
Open
470ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88272
Junction 88272 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56468-2 at junction 88272 so both are connected.
Open
471ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88275
Junction 88275 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56468-2 at junction 88275 so both are connected.
Open
472ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88279
Junction 88279 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56468-2 at junction 88279 so both are connected.
Open
473ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8828
Junction 8828 (degree 1) lies on pipe 89522-2 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 89522-2 at junction 8828 so both are connected.
Open
474ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88281
Junction 88281 (degree 1) lies on pipe 56468-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56468-2 at junction 88281 so both are connected.
Open
475ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88283
Junction 88283 (degree 1) lies on pipe 52863 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52863 at junction 88283 so both are connected.
Open
476ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88285
Junction 88285 (degree 2) lies on pipe 56474-1 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (12 m).
→ Split pipe 56474-1 at junction 88285 so both are connected.
Open
477ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88287
Junction 88287 (degree 1) lies on pipe 56474-1 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56474-1 at junction 88287 so both are connected.
Open
478ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88289
Junction 88289 (degree 1) lies on pipe 56474-2 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56474-2 at junction 88289 so both are connected.
Open
479ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8829
Junction 8829 (degree 1) lies on pipe 89522-1 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 89522-1 at junction 8829 so both are connected.
Open
480ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88291
Junction 88291 (degree 1) lies on pipe 56474-2 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56474-2 at junction 88291 so both are connected.
Open
481ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88293
Junction 88293 (degree 2) lies on pipe 56473 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (16 m).
→ Split pipe 56473 at junction 88293 so both are connected.
Open
482ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88295
Junction 88295 (degree 1) lies on pipe 56473 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56473 at junction 88295 so both are connected.
Open
483ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88297
Junction 88297 (degree 1) lies on pipe 56473 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56473 at junction 88297 so both are connected.
Open
484ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88299
Junction 88299 (degree 1) lies on pipe 52862 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52862 at junction 88299 so both are connected.
Open
485ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8830
Junction 8830 (degree 1) lies on pipe 89522-3 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 89522-3 at junction 8830 so both are connected.
Open
486ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88301
Junction 88301 (degree 1) lies on pipe 52862 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 52862 at junction 88301 so both are connected.
Open
487ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88303
Junction 88303 (degree 1) lies on pipe 52862 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52862 at junction 88303 so both are connected.
Open
488ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88306
Junction 88306 (degree 1) lies on pipe 56474-1 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56474-1 at junction 88306 so both are connected.
Open
489ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88308
Junction 88308 (degree 1) lies on pipe 56474-2 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56474-2 at junction 88308 so both are connected.
Open
490ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88310
Junction 88310 (degree 1) lies on pipe 56474-2 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56474-2 at junction 88310 so both are connected.
Open
491ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88312
Junction 88312 (degree 1) lies on pipe 56474-2 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56474-2 at junction 88312 so both are connected.
Open
492ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88314
Junction 88314 (degree 1) lies on pipe 56474-2 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56474-2 at junction 88314 so both are connected.
Open
493ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88316
Junction 88316 (degree 1) lies on pipe 56473 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56473 at junction 88316 so both are connected.
Open
494ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88318
Junction 88318 (degree 1) lies on pipe 56473 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56473 at junction 88318 so both are connected.
Open
495ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88320
Junction 88320 (degree 1) lies on pipe 56473 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56473 at junction 88320 so both are connected.
Open
496ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88323
Junction 88323 (degree 1) lies on pipe 56473 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 56473 at junction 88323 so both are connected.
Open
497ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88325
Junction 88325 (degree 1) lies on pipe 56473 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56473 at junction 88325 so both are connected.
Open
498ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8833
Junction 8833 (degree 1) lies on pipe 89522-3 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 89522-3 at junction 8833 so both are connected.
Open
499ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8834
Junction 8834 (degree 1) lies on pipe 89522-3 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 89522-3 at junction 8834 so both are connected.
Open
500ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8835
Junction 8835 (degree 1) lies on pipe 89522-3 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 89522-3 at junction 8835 so both are connected.
Open
501ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8840
Junction 8840 (degree 1) lies on pipe 53721 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 12 pipe(s) (322 m).
→ Split pipe 53721 at junction 8840 so both are connected.
Open
502ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88525
Junction 88525 (degree 1) lies on pipe 53720 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 53720 at junction 88525 so both are connected.
Open
503ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88527
Junction 88527 (degree 2) lies on pipe 53720 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (24 m).
→ Split pipe 53720 at junction 88527 so both are connected.
Open
504ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88529
Junction 88529 (degree 1) lies on pipe 53720 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53720 at junction 88529 so both are connected.
Open
505ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88531
Junction 88531 (degree 1) lies on pipe 53720 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53720 at junction 88531 so both are connected.
Open
506ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88533
Junction 88533 (degree 1) lies on pipe 53720 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53720 at junction 88533 so both are connected.
Open
507ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88535
Junction 88535 (degree 1) lies on pipe 53721 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53721 at junction 88535 so both are connected.
Open
508ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88537
Junction 88537 (degree 1) lies on pipe 53721 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 53721 at junction 88537 so both are connected.
Open
509ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88539
Junction 88539 (degree 1) lies on pipe 53723 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53723 at junction 88539 so both are connected.
Open
510ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88541
Junction 88541 (degree 1) lies on pipe 53723 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53723 at junction 88541 so both are connected.
Open
511ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88543
Junction 88543 (degree 1) lies on pipe 53724 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 53724 at junction 88543 so both are connected.
Open
512ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88545
Junction 88545 (degree 1) lies on pipe 53724 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53724 at junction 88545 so both are connected.
Open
513ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88547
Junction 88547 (degree 1) lies on pipe 53724 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 53724 at junction 88547 so both are connected.
Open
514ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88549
Junction 88549 (degree 1) lies on pipe 53724 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 53724 at junction 88549 so both are connected.
Open
515ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88551
Junction 88551 (degree 1) lies on pipe 53724 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 53724 at junction 88551 so both are connected.
Open
516ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88553
Junction 88553 (degree 1) lies on pipe 53724 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53724 at junction 88553 so both are connected.
Open
517ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88555
Junction 88555 (degree 1) lies on pipe 53723 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 53723 at junction 88555 so both are connected.
Open
518ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88557
Junction 88557 (degree 1) lies on pipe 53723 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53723 at junction 88557 so both are connected.
Open
519ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88559
Junction 88559 (degree 1) lies on pipe 53722 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53722 at junction 88559 so both are connected.
Open
520ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88561
Junction 88561 (degree 1) lies on pipe 53722 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 53722 at junction 88561 so both are connected.
Open
521ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88563
Junction 88563 (degree 1) lies on pipe 53721 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53721 at junction 88563 so both are connected.
Open
522ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88565
Junction 88565 (degree 1) lies on pipe 53721 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 53721 at junction 88565 so both are connected.
Open
523ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88567
Junction 88567 (degree 1) lies on pipe 53720 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 53720 at junction 88567 so both are connected.
Open
524ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88569
Junction 88569 (degree 1) lies on pipe 53720 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 53720 at junction 88569 so both are connected.
Open
525ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88572
Junction 88572 (degree 1) lies on pipe 53720 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 53720 at junction 88572 so both are connected.
Open
526ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88576
Junction 88576 (degree 2) lies on pipe 56525-4 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (11 m).
→ Split pipe 56525-4 at junction 88576 so both are connected.
Open
527ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88578
Junction 88578 (degree 1) lies on pipe 56525-4 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56525-4 at junction 88578 so both are connected.
Open
528ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88584
Junction 88584 (degree 1) lies on pipe 56525-4 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56525-4 at junction 88584 so both are connected.
Open
529ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88586
Junction 88586 (degree 1) lies on pipe 56525-4 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 56525-4 at junction 88586 so both are connected.
Open
530ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88588
Junction 88588 (degree 1) lies on pipe 56525-4 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 56525-4 at junction 88588 so both are connected.
Open
531ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88590
Junction 88590 (degree 1) lies on pipe 56525-4 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56525-4 at junction 88590 so both are connected.
Open
532ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88592
Junction 88592 (degree 1) lies on pipe 56525-4 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 56525-4 at junction 88592 so both are connected.
Open
533ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88594
Junction 88594 (degree 1) lies on pipe 56525-4 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56525-4 at junction 88594 so both are connected.
Open
534ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88597
Junction 88597 (degree 1) lies on pipe 56525-4 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56525-4 at junction 88597 so both are connected.
Open
535ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88621
Junction 88621 (degree 1) lies on pipe 53725 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53725 at junction 88621 so both are connected.
Open
536ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88623
Junction 88623 (degree 1) lies on pipe 53725 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (20 m).
→ Split pipe 53725 at junction 88623 so both are connected.
Open
537ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88625
Junction 88625 (degree 1) lies on pipe 53725 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 53725 at junction 88625 so both are connected.
Open
538ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88627
Junction 88627 (degree 1) lies on pipe 53725 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 53725 at junction 88627 so both are connected.
Open
539ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88629
Junction 88629 (degree 1) lies on pipe 53725 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 53725 at junction 88629 so both are connected.
Open
540ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88631
Junction 88631 (degree 1) lies on pipe 53725 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 53725 at junction 88631 so both are connected.
Open
541ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88633
Junction 88633 (degree 1) lies on pipe 53725 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 53725 at junction 88633 so both are connected.
Open
542ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88635
Junction 88635 (degree 1) lies on pipe 53725 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 53725 at junction 88635 so both are connected.
Open
543ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88637
Junction 88637 (degree 1) lies on pipe 53725 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 53725 at junction 88637 so both are connected.
Open
544ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88639
Junction 88639 (degree 1) lies on pipe 53725 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 53725 at junction 88639 so both are connected.
Open
545ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88641
Junction 88641 (degree 1) lies on pipe 89933 (DN 50, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 89933 at junction 88641 so both are connected.
Open
546ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88643
Junction 88643 (degree 1) lies on pipe 89933 (DN 50, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 89933 at junction 88643 so both are connected.
Open
547ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88645
Junction 88645 (degree 1) lies on pipe 89933 (DN 50, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 89933 at junction 88645 so both are connected.
Open
548ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88647
Junction 88647 (degree 1) lies on pipe 89933 (DN 50, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (45 m).
→ Split pipe 89933 at junction 88647 so both are connected.
Open
549ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88649
Junction 88649 (degree 1) lies on pipe 89933 (DN 50, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 89933 at junction 88649 so both are connected.
Open
550ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88651
Junction 88651 (degree 1) lies on pipe 89933 (DN 50, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 89933 at junction 88651 so both are connected.
Open
551ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88653
Junction 88653 (degree 1) lies on pipe 89933 (DN 50, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 89933 at junction 88653 so both are connected.
Open
552ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88655
Junction 88655 (degree 1) lies on pipe 89933 (DN 50, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 89933 at junction 88655 so both are connected.
Open
553ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88657
Junction 88657 (degree 1) lies on pipe 89933 (DN 50, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 89933 at junction 88657 so both are connected.
Open
554ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88659
Junction 88659 (degree 1) lies on pipe 89933 (DN 50, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 89933 at junction 88659 so both are connected.
Open
555ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88681
Junction 88681 (degree 1) lies on pipe 52864 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52864 at junction 88681 so both are connected.
Open
556ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88683
Junction 88683 (degree 1) lies on pipe 52864 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52864 at junction 88683 so both are connected.
Open
557ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88685
Junction 88685 (degree 1) lies on pipe 52864 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52864 at junction 88685 so both are connected.
Open
558ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88687
Junction 88687 (degree 1) lies on pipe 52864 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52864 at junction 88687 so both are connected.
Open
559ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88689
Junction 88689 (degree 1) lies on pipe 52864 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52864 at junction 88689 so both are connected.
Open
560ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88691
Junction 88691 (degree 1) lies on pipe 52864 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52864 at junction 88691 so both are connected.
Open
561ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88693
Junction 88693 (degree 1) lies on pipe 52864 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52864 at junction 88693 so both are connected.
Open
562ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88695
Junction 88695 (degree 1) lies on pipe 52864 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52864 at junction 88695 so both are connected.
Open
563ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88799
Junction 88799 (degree 1) lies on pipe 56469 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56469 at junction 88799 so both are connected.
Open
564ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88801
Junction 88801 (degree 1) lies on pipe 56469 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (17 m).
→ Split pipe 56469 at junction 88801 so both are connected.
Open
565ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88803
Junction 88803 (degree 1) lies on pipe 56469 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56469 at junction 88803 so both are connected.
Open
566ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88805
Junction 88805 (degree 1) lies on pipe 56469 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56469 at junction 88805 so both are connected.
Open
567ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88807
Junction 88807 (degree 1) lies on pipe 56469 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56469 at junction 88807 so both are connected.
Open
568ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88809
Junction 88809 (degree 1) lies on pipe 56469 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56469 at junction 88809 so both are connected.
Open
569ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88811
Junction 88811 (degree 1) lies on pipe 56469 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 56469 at junction 88811 so both are connected.
Open
570ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88813
Junction 88813 (degree 1) lies on pipe 56469 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 56469 at junction 88813 so both are connected.
Open
571ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88815
Junction 88815 (degree 1) lies on pipe 56470-1 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 56470-1 at junction 88815 so both are connected.
Open
572ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88817
Junction 88817 (degree 2) lies on pipe 56470-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (14 m).
→ Split pipe 56470-2 at junction 88817 so both are connected.
Open
573ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88819
Junction 88819 (degree 1) lies on pipe 56470-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 56470-2 at junction 88819 so both are connected.
Open
574ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88823
Junction 88823 (degree 1) lies on pipe 56470-3 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56470-3 at junction 88823 so both are connected.
Open
575ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88825
Junction 88825 (degree 2) lies on pipe 56470-3 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (24 m).
→ Split pipe 56470-3 at junction 88825 so both are connected.
Open
576ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88827
Junction 88827 (degree 1) lies on pipe 56470-3 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56470-3 at junction 88827 so both are connected.
Open
577ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88829
Junction 88829 (degree 1) lies on pipe 56470-1 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56470-1 at junction 88829 so both are connected.
Open
578ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88834
Junction 88834 (degree 1) lies on pipe 56470-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56470-2 at junction 88834 so both are connected.
Open
579ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88836
Junction 88836 (degree 1) lies on pipe 56470-3 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56470-3 at junction 88836 so both are connected.
Open
580ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88838
Junction 88838 (degree 1) lies on pipe 56470-3 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 56470-3 at junction 88838 so both are connected.
Open
581ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88840
Junction 88840 (degree 1) lies on pipe 56470-3 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56470-3 at junction 88840 so both are connected.
Open
582ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88842
Junction 88842 (degree 1) lies on pipe 56470-3 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (20 m).
→ Split pipe 56470-3 at junction 88842 so both are connected.
Open
583ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88844
Junction 88844 (degree 2) lies on pipe 56482 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (13 m).
→ Split pipe 56482 at junction 88844 so both are connected.
Open
584ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88846
Junction 88846 (degree 1) lies on pipe 56482 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (25 m).
→ Split pipe 56482 at junction 88846 so both are connected.
Open
585ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88848
Junction 88848 (degree 1) lies on pipe 56482 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56482 at junction 88848 so both are connected.
Open
586ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88850
Junction 88850 (degree 1) lies on pipe 56482 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56482 at junction 88850 so both are connected.
Open
587ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88852
Junction 88852 (degree 1) lies on pipe 56482 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56482 at junction 88852 so both are connected.
Open
588ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88854
Junction 88854 (degree 1) lies on pipe 56482 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56482 at junction 88854 so both are connected.
Open
589ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88856
Junction 88856 (degree 1) lies on pipe 56482 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56482 at junction 88856 so both are connected.
Open
590ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88858
Junction 88858 (degree 1) lies on pipe 56482 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56482 at junction 88858 so both are connected.
Open
591ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88860
Junction 88860 (degree 1) lies on pipe 56482 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56482 at junction 88860 so both are connected.
Open
592ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88862
Junction 88862 (degree 1) lies on pipe 56482 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56482 at junction 88862 so both are connected.
Open
593ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88865
Junction 88865 (degree 1) lies on pipe 56482 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56482 at junction 88865 so both are connected.
Open
594ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88867
Junction 88867 (degree 1) lies on pipe 56482 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56482 at junction 88867 so both are connected.
Open
595ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88869
Junction 88869 (degree 1) lies on pipe 56482 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56482 at junction 88869 so both are connected.
Open
596ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88871
Junction 88871 (degree 1) lies on pipe 56482 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56482 at junction 88871 so both are connected.
Open
597ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88873
Junction 88873 (degree 1) lies on pipe 56482 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56482 at junction 88873 so both are connected.
Open
598ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88875
Junction 88875 (degree 1) lies on pipe 56482 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56482 at junction 88875 so both are connected.
Open
599ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88930
Junction 88930 (degree 1) lies on pipe 52905-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52905-2 at junction 88930 so both are connected.
Open
600ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88932
Junction 88932 (degree 1) lies on pipe 52905-1 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52905-1 at junction 88932 so both are connected.
Open
601ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88934
Junction 88934 (degree 1) lies on pipe 52904 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 52904 at junction 88934 so both are connected.
Open
602ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88936
Junction 88936 (degree 1) lies on pipe 52904 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52904 at junction 88936 so both are connected.
Open
603ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88938
Junction 88938 (degree 1) lies on pipe 52904 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52904 at junction 88938 so both are connected.
Open
604ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88940
Junction 88940 (degree 1) lies on pipe 52904 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52904 at junction 88940 so both are connected.
Open
605ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88942
Junction 88942 (degree 1) lies on pipe 52904 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52904 at junction 88942 so both are connected.
Open
606ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88950
Junction 88950 (degree 1) lies on pipe 52904 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52904 at junction 88950 so both are connected.
Open
607ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88952
Junction 88952 (degree 1) lies on pipe 52904 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52904 at junction 88952 so both are connected.
Open
608ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89028
Junction 89028 (degree 1) lies on pipe 53505 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53505 at junction 89028 so both are connected.
Open
609ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89030
Junction 89030 (degree 1) lies on pipe 53505 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 53505 at junction 89030 so both are connected.
Open
610ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89032
Junction 89032 (degree 1) lies on pipe 53505 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 53505 at junction 89032 so both are connected.
Open
611ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89034
Junction 89034 (degree 1) lies on pipe 53505 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53505 at junction 89034 so both are connected.
Open
612ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89050
Junction 89050 (degree 1) lies on pipe 52881 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (17 m).
→ Split pipe 52881 at junction 89050 so both are connected.
Open
613ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89052
Junction 89052 (degree 1) lies on pipe 52881 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (19 m).
→ Split pipe 52881 at junction 89052 so both are connected.
Open
614ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89056
Junction 89056 (degree 1) lies on pipe 52877 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52877 at junction 89056 so both are connected.
Open
615ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89058
Junction 89058 (degree 1) lies on pipe 52877 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52877 at junction 89058 so both are connected.
Open
616ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89061
Junction 89061 (degree 1) lies on pipe 53731 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 53731 at junction 89061 so both are connected.
Open
617ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89063
Junction 89063 (degree 1) lies on pipe 53730-2 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (32 m).
→ Split pipe 53730-2 at junction 89063 so both are connected.
Open
618ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89065
Junction 89065 (degree 1) lies on pipe 53730-1 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 53730-1 at junction 89065 so both are connected.
Open
619ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89078
Junction 89078 (degree 1) lies on pipe 56526-3 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (21 m).
→ Split pipe 56526-3 at junction 89078 so both are connected.
Open
620ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89080
Junction 89080 (degree 1) lies on pipe 56526-3 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (34 m).
→ Split pipe 56526-3 at junction 89080 so both are connected.
Open
621ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89096
Junction 89096 (degree 1) lies on pipe 56447 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (23 m).
→ Split pipe 56447 at junction 89096 so both are connected.
Open
622ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89100
Junction 89100 (degree 1) lies on pipe 56447 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (20 m).
→ Split pipe 56447 at junction 89100 so both are connected.
Open
623ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89102
Junction 89102 (degree 1) lies on pipe 56466 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56466 at junction 89102 so both are connected.
Open
624ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89106
Junction 89106 (degree 1) lies on pipe 56412 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56412 at junction 89106 so both are connected.
Open
625ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89108
Junction 89108 (degree 1) lies on pipe 52882-1 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (20 m).
→ Split pipe 52882-1 at junction 89108 so both are connected.
Open
626ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89110
Junction 89110 (degree 1) lies on pipe 52884 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 52884 at junction 89110 so both are connected.
Open
627ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89112
Junction 89112 (degree 1) lies on pipe 52884 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 52884 at junction 89112 so both are connected.
Open
628ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89116
Junction 89116 (degree 1) lies on pipe 52879 (DN 125, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (22 m).
→ Split pipe 52879 at junction 89116 so both are connected.
Open
629ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89118
Junction 89118 (degree 1) lies on pipe 52879 (DN 125, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (22 m).
→ Split pipe 52879 at junction 89118 so both are connected.
Open
630ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89120
Junction 89120 (degree 1) lies on pipe 56551 (DN 125, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56551 at junction 89120 so both are connected.
Open
631ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89122
Junction 89122 (degree 1) lies on pipe 56551 (DN 125, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56551 at junction 89122 so both are connected.
Open
632ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89124
Junction 89124 (degree 1) lies on pipe 52879 (DN 125, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52879 at junction 89124 so both are connected.
Open
633ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89126
Junction 89126 (degree 1) lies on pipe 52879 (DN 125, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52879 at junction 89126 so both are connected.
Open
634ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89128
Junction 89128 (degree 1) lies on pipe 53727 (DN 32, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 53727 at junction 89128 so both are connected.
Open
635ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89130
Junction 89130 (degree 1) lies on pipe 53727 (DN 32, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 53727 at junction 89130 so both are connected.
Open
636ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89132
Junction 89132 (degree 1) lies on pipe 53727 (DN 32, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 53727 at junction 89132 so both are connected.
Open
637ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89134
Junction 89134 (degree 1) lies on pipe 53727 (DN 32, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 53727 at junction 89134 so both are connected.
Open
638ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89136
Junction 89136 (degree 1) lies on pipe 52888 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 52888 at junction 89136 so both are connected.
Open
639ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89150
Junction 89150 (degree 1) lies on pipe 53701 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (21 m).
→ Split pipe 53701 at junction 89150 so both are connected.
Open
640ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89152
Junction 89152 (degree 1) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 56492 at junction 89152 so both are connected.
Open
641ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89154
Junction 89154 (degree 1) lies on pipe 56492 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (25 m).
→ Split pipe 56492 at junction 89154 so both are connected.
Open
642ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89158
Junction 89158 (degree 1) lies on pipe 56464 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (66 m).
→ Split pipe 56464 at junction 89158 so both are connected.
Open
643ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89160
Junction 89160 (degree 2) lies on pipe 56411 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (40 m).
→ Split pipe 56411 at junction 89160 so both are connected.
Open
644ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89162
Junction 89162 (degree 1) lies on pipe 56411 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (31 m).
→ Split pipe 56411 at junction 89162 so both are connected.
Open
645ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89164
Junction 89164 (degree 2) lies on pipe 56411 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (44 m).
→ Split pipe 56411 at junction 89164 so both are connected.
Open
646ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89166
Junction 89166 (degree 1) lies on pipe 56412 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56412 at junction 89166 so both are connected.
Open
647ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89172
Junction 89172 (degree 1) lies on pipe 52873-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52873-2 at junction 89172 so both are connected.
Open
648ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89182
Junction 89182 (degree 1) lies on pipe 56493-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56493-2 at junction 89182 so both are connected.
Open
649ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89186
Junction 89186 (degree 1) lies on pipe 89718-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 89718-2 at junction 89186 so both are connected.
Open
650ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89188
Junction 89188 (degree 1) lies on pipe 89718-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (17 m).
→ Split pipe 89718-2 at junction 89188 so both are connected.
Open
651ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89190
Junction 89190 (degree 1) lies on pipe 89718-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 89718-2 at junction 89190 so both are connected.
Open
652ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89192
Junction 89192 (degree 1) lies on pipe 89718-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (23 m).
→ Split pipe 89718-2 at junction 89192 so both are connected.
Open
653ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89194
Junction 89194 (degree 1) lies on pipe 52910-3 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 52910-3 at junction 89194 so both are connected.
Open
654ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89198
Junction 89198 (degree 1) lies on pipe 89616 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 89616 at junction 89198 so both are connected.
Open
655ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89208
Junction 89208 (degree 1) lies on pipe 52978-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52978-2 at junction 89208 so both are connected.
Open
656ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89210
Junction 89210 (degree 1) lies on pipe 52978-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52978-2 at junction 89210 so both are connected.
Open
657ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89212
Junction 89212 (degree 1) lies on pipe 52978-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52978-2 at junction 89212 so both are connected.
Open
658ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89214
Junction 89214 (degree 1) lies on pipe 52978-2 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52978-2 at junction 89214 so both are connected.
Open
659ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89216
Junction 89216 (degree 1) lies on pipe 56557 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56557 at junction 89216 so both are connected.
Open
660ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89220
Junction 89220 (degree 1) lies on pipe 56473 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56473 at junction 89220 so both are connected.
Open
661ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89222
Junction 89222 (degree 1) lies on pipe 56473 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56473 at junction 89222 so both are connected.
Open
662ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89253
Junction 89253 (degree 2) lies on pipe 56525-4 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (24 m).
→ Split pipe 56525-4 at junction 89253 so both are connected.
Open
663ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89274
Junction 89274 (degree 1) lies on pipe 56469 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (28 m).
→ Split pipe 56469 at junction 89274 so both are connected.
Open
664ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89276
Junction 89276 (degree 1) lies on pipe 56469 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56469 at junction 89276 so both are connected.
Open
665ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89278
Junction 89278 (degree 1) lies on pipe 56470-3 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56470-3 at junction 89278 so both are connected.
Open
666ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89280
Junction 89280 (degree 1) lies on pipe 56470-3 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (23 m).
→ Split pipe 56470-3 at junction 89280 so both are connected.
Open
667ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89282
Junction 89282 (degree 1) lies on pipe 56470-3 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (21 m).
→ Split pipe 56470-3 at junction 89282 so both are connected.
Open
668ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89285
Junction 89285 (degree 1) lies on pipe 56470-3 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56470-3 at junction 89285 so both are connected.
Open
669ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89287
Junction 89287 (degree 1) lies on pipe 56482 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (28 m).
→ Split pipe 56482 at junction 89287 so both are connected.
Open
670ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89318
Junction 89318 (degree 1) lies on pipe 56419-1 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56419-1 at junction 89318 so both are connected.
Open
671ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89345
Junction 89345 (degree 1) lies on pipe 56411 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (31 m).
→ Split pipe 56411 at junction 89345 so both are connected.
Open
672ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89348
Junction 89348 (degree 1) lies on pipe 56551 (DN 125, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (65 m).
→ Split pipe 56551 at junction 89348 so both are connected.
Open
673ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89363
Junction 89363 (degree 1) lies on pipe 52887 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52887 at junction 89363 so both are connected.
Open
674ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89365
Junction 89365 (degree 1) lies on pipe 52887 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52887 at junction 89365 so both are connected.
Open
675ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89367
Junction 89367 (degree 1) lies on pipe 52887 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52887 at junction 89367 so both are connected.
Open
676ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89369
Junction 89369 (degree 1) lies on pipe 52887 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (25 m).
→ Split pipe 52887 at junction 89369 so both are connected.
Open
677ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89377
Junction 89377 (degree 1) lies on pipe 89718-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 89718-2 at junction 89377 so both are connected.
Open
678ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89391
Junction 89391 (degree 1) lies on pipe 52873-1 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (28 m).
→ Split pipe 52873-1 at junction 89391 so both are connected.
Open
679ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89403
Junction 89403 (degree 1) lies on pipe 52872 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 52872 at junction 89403 so both are connected.
Open
680ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89405
Junction 89405 (degree 1) lies on pipe 56493-3 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56493-3 at junction 89405 so both are connected.
Open
681ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89407
Junction 89407 (degree 1) lies on pipe 56493-3 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56493-3 at junction 89407 so both are connected.
Open
682ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89409
Junction 89409 (degree 1) lies on pipe 56493-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56493-2 at junction 89409 so both are connected.
Open
683ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89411
Junction 89411 (degree 1) lies on pipe 56493-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56493-2 at junction 89411 so both are connected.
Open
684ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89413
Junction 89413 (degree 1) lies on pipe 56493-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56493-2 at junction 89413 so both are connected.
Open
685ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89415
Junction 89415 (degree 1) lies on pipe 56493-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56493-2 at junction 89415 so both are connected.
Open
686ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89419
Junction 89419 (degree 1) lies on pipe 52855-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52855-2 at junction 89419 so both are connected.
Open
687ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89421
Junction 89421 (degree 1) lies on pipe 52856 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52856 at junction 89421 so both are connected.
Open
688ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89423
Junction 89423 (degree 1) lies on pipe 52859 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52859 at junction 89423 so both are connected.
Open
689ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89425
Junction 89425 (degree 2) lies on pipe 52859 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (20 m).
→ Split pipe 52859 at junction 89425 so both are connected.
Open
690ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89427
Junction 89427 (degree 1) lies on pipe 52859 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 52859 at junction 89427 so both are connected.
Open
691ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89429
Junction 89429 (degree 1) lies on pipe 52859 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 52859 at junction 89429 so both are connected.
Open
692ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89431
Junction 89431 (degree 1) lies on pipe 52860 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 52860 at junction 89431 so both are connected.
Open
693ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89433
Junction 89433 (degree 1) lies on pipe 52882-1 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52882-1 at junction 89433 so both are connected.
Open
694ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89438
Junction 89438 (degree 1) lies on pipe 52873-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52873-2 at junction 89438 so both are connected.
Open
695ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89440
Junction 89440 (degree 1) lies on pipe 52873-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52873-2 at junction 89440 so both are connected.
Open
696ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89442
Junction 89442 (degree 1) lies on pipe 52910-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52910-2 at junction 89442 so both are connected.
Open
697ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89444
Junction 89444 (degree 1) lies on pipe 52910-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52910-2 at junction 89444 so both are connected.
Open
698ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89446
Junction 89446 (degree 1) lies on pipe 52910-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 52910-2 at junction 89446 so both are connected.
Open
699ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89448
Junction 89448 (degree 1) lies on pipe 56369-2 (transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 56369-2 at junction 89448 so both are connected.
Open
700ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89450
Junction 89450 (degree 1) lies on pipe 56369-2 (transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56369-2 at junction 89450 so both are connected.
Open
701ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89454
Junction 89454 (degree 1) lies on pipe 52978-1 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52978-1 at junction 89454 so both are connected.
Open
702ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89473
Junction 89473 (degree 1) lies on pipe 56430 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (39 m).
→ Split pipe 56430 at junction 89473 so both are connected.
Open
703ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89493
Junction 89493 (degree 1) lies on pipe 52879 (DN 125, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 52879 at junction 89493 so both are connected.
Open
704ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89495
Junction 89495 (degree 1) lies on pipe 52910-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52910-2 at junction 89495 so both are connected.
Open
705ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89499
Junction 89499 (degree 1) lies on pipe 52910-1 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52910-1 at junction 89499 so both are connected.
Open
706ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89501
Junction 89501 (degree 1) lies on pipe 52910-1 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52910-1 at junction 89501 so both are connected.
Open
707ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89503
Junction 89503 (degree 1) lies on pipe 52910-1 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 52910-1 at junction 89503 so both are connected.
Open
708ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89505
Junction 89505 (degree 1) lies on pipe 52910-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (26 m).
→ Split pipe 52910-2 at junction 89505 so both are connected.
Open
709ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89507
Junction 89507 (degree 1) lies on pipe 56369-1 (transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56369-1 at junction 89507 so both are connected.
Open
710ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89509
Junction 89509 (degree 1) lies on pipe 56369-1 (transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 56369-1 at junction 89509 so both are connected.
Open
711ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89511
Junction 89511 (degree 1) lies on pipe 89616 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 89616 at junction 89511 so both are connected.
Open
712ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89513
Junction 89513 (degree 1) lies on pipe 89616 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 89616 at junction 89513 so both are connected.
Open
713ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89515
Junction 89515 (degree 1) lies on pipe 89616 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 89616 at junction 89515 so both are connected.
Open
714ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89519
Junction 89519 (degree 1) lies on pipe 89616 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 89616 at junction 89519 so both are connected.
Open
715ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89521
Junction 89521 (degree 1) lies on pipe 89616 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (19 m).
→ Split pipe 89616 at junction 89521 so both are connected.
Open
716ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89524
Junction 89524 (degree 1) lies on pipe 56557 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56557 at junction 89524 so both are connected.
Open
717ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89526
Junction 89526 (degree 1) lies on pipe 56557 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56557 at junction 89526 so both are connected.
Open
718ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89528
Junction 89528 (degree 1) lies on pipe 56557 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56557 at junction 89528 so both are connected.
Open
719ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89530
Junction 89530 (degree 1) lies on pipe 56557 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (19 m).
→ Split pipe 56557 at junction 89530 so both are connected.
Open
720ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89532
Junction 89532 (degree 1) lies on pipe 56557 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 56557 at junction 89532 so both are connected.
Open
721ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89533
Junction 89533 (degree 1) lies on pipe 56557 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (20 m).
→ Split pipe 56557 at junction 89533 so both are connected.
Open
722ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89535
Junction 89535 (degree 1) lies on pipe 56557 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (30 m).
→ Split pipe 56557 at junction 89535 so both are connected.
Open
723ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89537
Junction 89537 (degree 1) lies on pipe 56557 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56557 at junction 89537 so both are connected.
Open
724ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89540
Junction 89540 (degree 1) lies on pipe 56557 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (27 m).
→ Split pipe 56557 at junction 89540 so both are connected.
Open
725ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89542
Junction 89542 (degree 1) lies on pipe 56557 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56557 at junction 89542 so both are connected.
Open
726ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89544
Junction 89544 (degree 1) lies on pipe 56557 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 56557 at junction 89544 so both are connected.
Open
727ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89546
Junction 89546 (degree 1) lies on pipe 56557 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 56557 at junction 89546 so both are connected.
Open
728ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89548
Junction 89548 (degree 1) lies on pipe 56557 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 56557 at junction 89548 so both are connected.
Open
729ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89550
Junction 89550 (degree 1) lies on pipe 56557 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 56557 at junction 89550 so both are connected.
Open
730ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89560
Junction 89560 (degree 1) lies on pipe 52905-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (27 m).
→ Split pipe 52905-2 at junction 89560 so both are connected.
Open
731ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89562
Junction 89562 (degree 1) lies on pipe 52905-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (29 m).
→ Split pipe 52905-2 at junction 89562 so both are connected.
Open
732ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89564
Junction 89564 (degree 1) lies on pipe 52905-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (30 m).
→ Split pipe 52905-2 at junction 89564 so both are connected.
Open
733ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89566
Junction 89566 (degree 1) lies on pipe 52875 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (70 m).
→ Split pipe 52875 at junction 89566 so both are connected.
Open
734ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89568
Junction 89568 (degree 1) lies on pipe 52908-1 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52908-1 at junction 89568 so both are connected.
Open
735ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89570
Junction 89570 (degree 1) lies on pipe 52880-2 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52880-2 at junction 89570 so both are connected.
Open
736ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89572
Junction 89572 (degree 1) lies on pipe 52880-2 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 52880-2 at junction 89572 so both are connected.
Open
737ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89574
Junction 89574 (degree 1) lies on pipe 52908-2 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52908-2 at junction 89574 so both are connected.
Open
738ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89576
Junction 89576 (degree 1) lies on pipe 53503 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (33 m).
→ Split pipe 53503 at junction 89576 so both are connected.
Open
739ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89582
Junction 89582 (degree 1) lies on pipe 56395 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (29 m).
→ Split pipe 56395 at junction 89582 so both are connected.
Open
740ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89584
Junction 89584 (degree 1) lies on pipe 53705 (DN 90, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 53705 at junction 89584 so both are connected.
Open
741ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89617
Junction 89617 (degree 1) lies on pipe 56464 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (42 m).
→ Split pipe 56464 at junction 89617 so both are connected.
Open
742ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89631
Junction 89631 (degree 1) lies on pipe 53521 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (56 m).
→ Split pipe 53521 at junction 89631 so both are connected.
Open
743ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89684
Junction 89684 (degree 1) lies on pipe 53734 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 53734 at junction 89684 so both are connected.
Open
744ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89686
Junction 89686 (degree 1) lies on pipe 53734 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 53734 at junction 89686 so both are connected.
Open
745ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89688
Junction 89688 (degree 1) lies on pipe 53734 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 53734 at junction 89688 so both are connected.
Open
746ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89690
Junction 89690 (degree 1) lies on pipe 53734 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 53734 at junction 89690 so both are connected.
Open
747ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89692
Junction 89692 (degree 1) lies on pipe 53734 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (23 m).
→ Split pipe 53734 at junction 89692 so both are connected.
Open
748ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89694
Junction 89694 (degree 1) lies on pipe 53734 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 53734 at junction 89694 so both are connected.
Open
749ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89696
Junction 89696 (degree 1) lies on pipe 53734 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (56 m).
→ Split pipe 53734 at junction 89696 so both are connected.
Open
750ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89698
Junction 89698 (degree 1) lies on pipe 53734 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 53734 at junction 89698 so both are connected.
Open
751ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89700
Junction 89700 (degree 1) lies on pipe 53734 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (37 m).
→ Split pipe 53734 at junction 89700 so both are connected.
Open
752ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89710
Junction 89710 (degree 1) lies on pipe 52896-1 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52896-1 at junction 89710 so both are connected.
Open
753ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89712
Junction 89712 (degree 1) lies on pipe 52837 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (23 m).
→ Split pipe 52837 at junction 89712 so both are connected.
Open
754ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89714
Junction 89714 (degree 1) lies on pipe 52898 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (22 m).
→ Split pipe 52898 at junction 89714 so both are connected.
Open
755ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89718
Junction 89718 (degree 1) lies on pipe 52838 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52838 at junction 89718 so both are connected.
Open
756ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89720
Junction 89720 (degree 1) lies on pipe 52839 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52839 at junction 89720 so both are connected.
Open
757ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89722
Junction 89722 (degree 1) lies on pipe 52841 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52841 at junction 89722 so both are connected.
Open
758ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89723
Junction 89723 (degree 1) lies on pipe 52837 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52837 at junction 89723 so both are connected.
Open
759ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89726
Junction 89726 (degree 1) lies on pipe 52903 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52903 at junction 89726 so both are connected.
Open
760ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89728
Junction 89728 (degree 1) lies on pipe 52903 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52903 at junction 89728 so both are connected.
Open
761ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89730
Junction 89730 (degree 1) lies on pipe 52902 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52902 at junction 89730 so both are connected.
Open
762ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89732
Junction 89732 (degree 1) lies on pipe 52896-1 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 52896-1 at junction 89732 so both are connected.
Open
763ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89733
Junction 89733 (degree 1) lies on pipe 52898 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (19 m).
→ Split pipe 52898 at junction 89733 so both are connected.
Open
764ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89735
Junction 89735 (degree 1) lies on pipe 52898 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (19 m).
→ Split pipe 52898 at junction 89735 so both are connected.
Open
765ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89753
Junction 89753 (degree 1) lies on pipe 56442 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 56442 at junction 89753 so both are connected.
Open
766ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89784
Junction 89784 (degree 1) lies on pipe 56442 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56442 at junction 89784 so both are connected.
Open
767ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89805
Junction 89805 (degree 1) lies on pipe 56369-1 (transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56369-1 at junction 89805 so both are connected.
Open
768ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89807
Junction 89807 (degree 1) lies on pipe 56369-1 (transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Split pipe 56369-1 at junction 89807 so both are connected.
Open
769ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89809
Junction 89809 (degree 1) lies on pipe 56369-1 (transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56369-1 at junction 89809 so both are connected.
Open
770ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89811
Junction 89811 (degree 1) lies on pipe 56369-3 (transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56369-3 at junction 89811 so both are connected.
Open
771ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89813
Junction 89813 (degree 1) lies on pipe 56369-3 (transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56369-3 at junction 89813 so both are connected.
Open
772ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89815
Junction 89815 (degree 1) lies on pipe 56369-3 (transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56369-3 at junction 89815 so both are connected.
Open
773ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89817
Junction 89817 (degree 1) lies on pipe 52741-1 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52741-1 at junction 89817 so both are connected.
Open
774ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89821
Junction 89821 (degree 1) lies on pipe 56369-2 (transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56369-2 at junction 89821 so both are connected.
Open
775ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89825
Junction 89825 (degree 1) lies on pipe 56369-3 (transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56369-3 at junction 89825 so both are connected.
Open
776ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89827
Junction 89827 (degree 1) lies on pipe 56369-3 (transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56369-3 at junction 89827 so both are connected.
Open
777ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89829
Junction 89829 (degree 1) lies on pipe 56369-3 (transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56369-3 at junction 89829 so both are connected.
Open
778ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89831
Junction 89831 (degree 1) lies on pipe 56369-3 (transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56369-3 at junction 89831 so both are connected.
Open
779ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89833
Junction 89833 (degree 1) lies on pipe 56369-3 (transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 56369-3 at junction 89833 so both are connected.
Open
780ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89835
Junction 89835 (degree 1) lies on pipe 56369-3 (transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56369-3 at junction 89835 so both are connected.
Open
781ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89839
Junction 89839 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52741-2 at junction 89839 so both are connected.
Open
782ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89841
Junction 89841 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52741-2 at junction 89841 so both are connected.
Open
783ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89843
Junction 89843 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52741-2 at junction 89843 so both are connected.
Open
784ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89845
Junction 89845 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52741-2 at junction 89845 so both are connected.
Open
785ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89847
Junction 89847 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52741-2 at junction 89847 so both are connected.
Open
786ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89849
Junction 89849 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52741-2 at junction 89849 so both are connected.
Open
787ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89851
Junction 89851 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52741-2 at junction 89851 so both are connected.
Open
788ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89853
Junction 89853 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52741-2 at junction 89853 so both are connected.
Open
789ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89855
Junction 89855 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 52741-2 at junction 89855 so both are connected.
Open
790ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89857
Junction 89857 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52741-2 at junction 89857 so both are connected.
Open
791ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89859
Junction 89859 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52741-2 at junction 89859 so both are connected.
Open
792ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89861
Junction 89861 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52741-2 at junction 89861 so both are connected.
Open
793ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89863
Junction 89863 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (19 m).
→ Split pipe 52741-2 at junction 89863 so both are connected.
Open
794ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89865
Junction 89865 (degree 1) lies on pipe 52741-1 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52741-1 at junction 89865 so both are connected.
Open
795ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89867
Junction 89867 (degree 1) lies on pipe 52741-1 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52741-1 at junction 89867 so both are connected.
Open
796ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89869
Junction 89869 (degree 1) lies on pipe 52741-1 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52741-1 at junction 89869 so both are connected.
Open
797ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89871
Junction 89871 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52741-2 at junction 89871 so both are connected.
Open
798ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89873
Junction 89873 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 52741-2 at junction 89873 so both are connected.
Open
799ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89875
Junction 89875 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52741-2 at junction 89875 so both are connected.
Open
800ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89877
Junction 89877 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52741-2 at junction 89877 so both are connected.
Open
801ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89879
Junction 89879 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52741-2 at junction 89879 so both are connected.
Open
802ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89881
Junction 89881 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 52741-2 at junction 89881 so both are connected.
Open
803ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89883
Junction 89883 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52741-2 at junction 89883 so both are connected.
Open
804ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89885
Junction 89885 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (20 m).
→ Split pipe 52741-2 at junction 89885 so both are connected.
Open
805ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89887
Junction 89887 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52741-2 at junction 89887 so both are connected.
Open
806ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89889
Junction 89889 (degree 1) lies on pipe 52741-2 (DN 40, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 52741-2 at junction 89889 so both are connected.
Open
807ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89891
Junction 89891 (degree 1) lies on pipe 53497-3 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 53497-3 at junction 89891 so both are connected.
Open
808ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89893
Junction 89893 (degree 1) lies on pipe 53497-3 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 53497-3 at junction 89893 so both are connected.
Open
809ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89899
Junction 89899 (degree 1) lies on pipe 53499 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 53499 at junction 89899 so both are connected.
Open
810ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89901
Junction 89901 (degree 1) lies on pipe 53499 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53499 at junction 89901 so both are connected.
Open
811ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89903
Junction 89903 (degree 1) lies on pipe 53497-1 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 53497-1 at junction 89903 so both are connected.
Open
812ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89905
Junction 89905 (degree 1) lies on pipe 53497-1 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 53497-1 at junction 89905 so both are connected.
Open
813ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89907
Junction 89907 (degree 1) lies on pipe 53497-1 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 53497-1 at junction 89907 so both are connected.
Open
814ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89909
Junction 89909 (degree 1) lies on pipe 53497-1 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 53497-1 at junction 89909 so both are connected.
Open
815ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89911
Junction 89911 (degree 1) lies on pipe 53497-1 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 53497-1 at junction 89911 so both are connected.
Open
816ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89913
Junction 89913 (degree 1) lies on pipe 53497-1 (DN 25, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 53497-1 at junction 89913 so both are connected.
Open
817ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89924
Junction 89924 (degree 1) lies on pipe 56447 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (21 m).
→ Split pipe 56447 at junction 89924 so both are connected.
Open
818ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89927
Junction 89927 (degree 1) lies on pipe 56447 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56447 at junction 89927 so both are connected.
Open
819ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89933
Junction 89933 (degree 1) lies on pipe 56418-1 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 56418-1 at junction 89933 so both are connected.
Open
820ERROR
P100
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
90009
Junction 90009 (degree 1) lies on pipe 52871 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (102 m).
→ Split pipe 52871 at junction 90009 so both are connected.
Open
821ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
11697
Junction 11697 (degree 1) is 0.30 m from pipe 56681-15 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 10 pipe(s) (281 m).
→ Extend/snap to pipe 56681-15 and split it there, or confirm the gap is real.
Open
822ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
14624
Junction 14624 (degree 1) is 0.63 m from pipe 52877 (DN 200, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (32 m).
→ Extend/snap to pipe 52877 and split it there, or confirm the gap is real.
Open
823ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
18681
Junction 18681 (degree 1) is 0.91 m from pipe 95354 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Extend/snap to pipe 95354 and split it there, or confirm the gap is real.
Open
824ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
18769
Junction 18769 (degree 1) is 0.75 m from pipe 95312 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Extend/snap to pipe 95312 and split it there, or confirm the gap is real.
Open
825ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
20002
Junction 20002 (degree 1) is 0.98 m from pipe 95313 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Extend/snap to pipe 95313 and split it there, or confirm the gap is real.
Open
826ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
20028
Junction 20028 (degree 1) is 0.20 m from pipe 56469 (DN 63, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 5 pipe(s) (494 m).
→ Extend/snap to pipe 56469 and split it there, or confirm the gap is real.
Open
827ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
25081
Junction 25081 (degree 1) is 0.98 m from pipe 56477 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Extend/snap to pipe 56477 and split it there, or confirm the gap is real.
Open
828ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
33494
Junction 33494 (degree 1) is 0.15 m from pipe 52905-2 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (36 m).
→ Extend/snap to pipe 52905-2 and split it there, or confirm the gap is real.
Open
829ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
58472
Junction 58472 (degree 1) is 0.57 m from pipe 93649 (DN 110, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 7 pipe(s) (2,354 m).
→ Extend/snap to pipe 93649 and split it there, or confirm the gap is real.
Open
830ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
67607
Junction 67607 (degree 1) is 0.14 m from pipe 56427 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 16 pipe(s) (388 m).
→ Extend/snap to pipe 56427 and split it there, or confirm the gap is real.
Open
831ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78341
Junction 78341 (degree 1) is 0.51 m from pipe 53737 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 179 pipe(s) (3,395 m).
→ Extend/snap to pipe 53737 and split it there, or confirm the gap is real.
Open
832ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78763
Junction 78763 (degree 1) is 0.88 m from pipe 53737 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 179 pipe(s) (3,395 m).
→ Extend/snap to pipe 53737 and split it there, or confirm the gap is real.
Open
833ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78765
Junction 78765 (degree 1) is 0.78 m from pipe 53737 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 179 pipe(s) (3,395 m).
→ Extend/snap to pipe 53737 and split it there, or confirm the gap is real.
Open
834ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
8633
Junction 8633 (degree 1) is 0.64 m from pipe 53737 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 179 pipe(s) (3,395 m).
→ Extend/snap to pipe 53737 and split it there, or confirm the gap is real.
Open
835ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
8643
Junction 8643 (degree 1) is 0.66 m from pipe 53737 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 179 pipe(s) (3,395 m).
→ Extend/snap to pipe 53737 and split it there, or confirm the gap is real.
Open
836ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
8645
Junction 8645 (degree 1) is 0.63 m from pipe 53737 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 179 pipe(s) (3,395 m).
→ Extend/snap to pipe 53737 and split it there, or confirm the gap is real.
Open
837ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
87755
Junction 87755 (degree 1) is 0.05 m from pipe 56407-2 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Extend/snap to pipe 56407-2 and split it there, or confirm the gap is real.
Open
838ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
88944
Junction 88944 (degree 1) is 0.06 m from pipe 52904 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Extend/snap to pipe 52904 and split it there, or confirm the gap is real.
Open
839ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
88948
Junction 88948 (degree 1) is 0.11 m from pipe 52904 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Extend/snap to pipe 52904 and split it there, or confirm the gap is real.
Open
840ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
88954
Junction 88954 (degree 1) is 0.05 m from pipe 52904 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Extend/snap to pipe 52904 and split it there, or confirm the gap is real.
Open
841ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
88956
Junction 88956 (degree 1) is 0.08 m from pipe 52904 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Extend/snap to pipe 52904 and split it there, or confirm the gap is real.
Open
842ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
88958
Junction 88958 (degree 1) is 0.07 m from pipe 52904 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Extend/snap to pipe 52904 and split it there, or confirm the gap is real.
Open
843ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
88961
Junction 88961 (degree 1) is 0.10 m from pipe 52904 (DN 150, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Extend/snap to pipe 52904 and split it there, or confirm the gap is real.
Open
844ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89104
Junction 89104 (degree 1) is 0.13 m from pipe 56407-2 (DN 100, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Extend/snap to pipe 56407-2 and split it there, or confirm the gap is real.
Open
845ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
9160
Junction 9160 (degree 1) is 0.30 m from pipe 95578 (DN 160, transmission) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 6 pipe(s) (2,996 m).
→ Extend/snap to pipe 95578 and split it there, or confirm the gap is real.
Open
846ERROR
P100
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
9261
Junction 9261 (degree 1) is 0.25 m from pipe 56380 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 10 pipe(s) (556 m).
→ Extend/snap to pipe 56380 and split it there, or confirm the gap is real.
Open
847ERROR
P98
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
116100
Junction 116100 (degree 1) lies on pipe 56542 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 4 pipe(s) (285 m).
→ Split pipe 56542 at junction 116100 so both are connected.
Open
848ERROR
P98
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3037
Junction 3037 (degree 1) lies on pipe 56462 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 3 pipe(s) (43 m).
→ Split pipe 56462 at junction 3037 so both are connected.
Open
849ERROR
P96
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
18 pipes near 53740
18 pipe(s), 1,101 m in total incl. 18 main(s), are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
850ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3033
Junction 3033 (degree 1) lies on pipe 56462 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (19 m).
→ Split pipe 56462 at junction 3033 so both are connected.
Open
851ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87106
Junction 87106 (degree 2) lies on pipe 52835-3 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (24 m).
→ Split pipe 52835-3 at junction 87106 so both are connected.
Open
852ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87116
Junction 87116 (degree 2) lies on pipe 52835-2 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (21 m).
→ Split pipe 52835-2 at junction 87116 so both are connected.
Open
853ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87124
Junction 87124 (degree 2) lies on pipe 52835-2 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (24 m).
→ Split pipe 52835-2 at junction 87124 so both are connected.
Open
854ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87291
Junction 87291 (degree 2) lies on pipe 56568 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (19 m).
→ Split pipe 56568 at junction 87291 so both are connected.
Open
855ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87295
Junction 87295 (degree 2) lies on pipe 56568 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (19 m).
→ Split pipe 56568 at junction 87295 so both are connected.
Open
856ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87297
Junction 87297 (degree 2) lies on pipe 56568 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (20 m).
→ Split pipe 56568 at junction 87297 so both are connected.
Open
857ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87299
Junction 87299 (degree 2) lies on pipe 56568 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (23 m).
→ Split pipe 56568 at junction 87299 so both are connected.
Open
858ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87301
Junction 87301 (degree 2) lies on pipe 56572 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (20 m).
→ Split pipe 56572 at junction 87301 so both are connected.
Open
859ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87322
Junction 87322 (degree 2) lies on pipe 52827-9 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (20 m).
→ Split pipe 52827-9 at junction 87322 so both are connected.
Open
860ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87426
Junction 87426 (degree 2) lies on pipe 56417 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (19 m).
→ Split pipe 56417 at junction 87426 so both are connected.
Open
861ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87437
Junction 87437 (degree 2) lies on pipe 56417 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (20 m).
→ Split pipe 56417 at junction 87437 so both are connected.
Open
862ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87467
Junction 87467 (degree 2) lies on pipe 56416-1 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (28 m).
→ Split pipe 56416-1 at junction 87467 so both are connected.
Open
863ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87500
Junction 87500 (degree 2) lies on pipe 52823 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (18 m).
→ Split pipe 52823 at junction 87500 so both are connected.
Open
864ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87503
Junction 87503 (degree 2) lies on pipe 52823 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (22 m).
→ Split pipe 52823 at junction 87503 so both are connected.
Open
865ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87506
Junction 87506 (degree 2) lies on pipe 52823 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (21 m).
→ Split pipe 52823 at junction 87506 so both are connected.
Open
866ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87517
Junction 87517 (degree 2) lies on pipe 52822-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (23 m).
→ Split pipe 52822-2 at junction 87517 so both are connected.
Open
867ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87528
Junction 87528 (degree 2) lies on pipe 52822-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (40 m).
→ Split pipe 52822-1 at junction 87528 so both are connected.
Open
868ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87532
Junction 87532 (degree 2) lies on pipe 52822-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (25 m).
→ Split pipe 52822-1 at junction 87532 so both are connected.
Open
869ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87534
Junction 87534 (degree 2) lies on pipe 52822-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (25 m).
→ Split pipe 52822-1 at junction 87534 so both are connected.
Open
870ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87543
Junction 87543 (degree 2) lies on pipe 52822-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (57 m).
→ Split pipe 52822-1 at junction 87543 so both are connected.
Open
871ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87545
Junction 87545 (degree 2) lies on pipe 52822-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (30 m).
→ Split pipe 52822-1 at junction 87545 so both are connected.
Open
872ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87549
Junction 87549 (degree 2) lies on pipe 52822-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (59 m).
→ Split pipe 52822-1 at junction 87549 so both are connected.
Open
873ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87555
Junction 87555 (degree 2) lies on pipe 52820-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (21 m).
→ Split pipe 52820-2 at junction 87555 so both are connected.
Open
874ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87602
Junction 87602 (degree 2) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (20 m).
→ Split pipe 52820-1 at junction 87602 so both are connected.
Open
875ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87604
Junction 87604 (degree 2) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (20 m).
→ Split pipe 52820-1 at junction 87604 so both are connected.
Open
876ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87612
Junction 87612 (degree 2) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (21 m).
→ Split pipe 52820-1 at junction 87612 so both are connected.
Open
877ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87617
Junction 87617 (degree 2) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (26 m).
→ Split pipe 52820-1 at junction 87617 so both are connected.
Open
878ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87626
Junction 87626 (degree 2) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (26 m).
→ Split pipe 52820-1 at junction 87626 so both are connected.
Open
879ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87695
Junction 87695 (degree 2) lies on pipe 56384 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (29 m).
→ Split pipe 56384 at junction 87695 so both are connected.
Open
880ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88367
Junction 88367 (degree 2) lies on pipe 52832-1 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (20 m).
→ Split pipe 52832-1 at junction 88367 so both are connected.
Open
881ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88393
Junction 88393 (degree 2) lies on pipe 56415 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (19 m).
→ Split pipe 56415 at junction 88393 so both are connected.
Open
882ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88404
Junction 88404 (degree 2) lies on pipe 56415 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (22 m).
→ Split pipe 56415 at junction 88404 so both are connected.
Open
883ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88406
Junction 88406 (degree 2) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (24 m).
→ Split pipe 56414 at junction 88406 so both are connected.
Open
884ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88408
Junction 88408 (degree 2) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (19 m).
→ Split pipe 56414 at junction 88408 so both are connected.
Open
885ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88412
Junction 88412 (degree 2) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (17 m).
→ Split pipe 56414 at junction 88412 so both are connected.
Open
886ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88418
Junction 88418 (degree 2) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (19 m).
→ Split pipe 56414 at junction 88418 so both are connected.
Open
887ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88723
Junction 88723 (degree 2) lies on pipe 52895 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (21 m).
→ Split pipe 52895 at junction 88723 so both are connected.
Open
888ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88728
Junction 88728 (degree 2) lies on pipe 52895 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (22 m).
→ Split pipe 52895 at junction 88728 so both are connected.
Open
889ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88735
Junction 88735 (degree 2) lies on pipe 52895 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (24 m).
→ Split pipe 52895 at junction 88735 so both are connected.
Open
890ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88740
Junction 88740 (degree 2) lies on pipe 52895 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (19 m).
→ Split pipe 52895 at junction 88740 so both are connected.
Open
891ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88742
Junction 88742 (degree 2) lies on pipe 52895 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (23 m).
→ Split pipe 52895 at junction 88742 so both are connected.
Open
892ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88744
Junction 88744 (degree 2) lies on pipe 52895 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (23 m).
→ Split pipe 52895 at junction 88744 so both are connected.
Open
893ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89006
Junction 89006 (degree 2) lies on pipe 56368 (distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (24 m).
→ Split pipe 56368 at junction 89006 so both are connected.
Open
894ERROR
P96
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9781
Junction 9781 (degree 2) lies on pipe 89723-11 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (16 m).
→ Split pipe 89723-11 at junction 9781 so both are connected.
Open
895ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
14587
Junction 14587 (degree 1) lies on pipe 52827-7 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Split pipe 52827-7 at junction 14587 so both are connected.
Open
896ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
14588
Junction 14588 (degree 1) lies on pipe 91552-6 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 91552-6 at junction 14588 so both are connected.
Open
897ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
14596
Junction 14596 (degree 1) lies on pipe 52827-9 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 52827-9 at junction 14596 so both are connected.
Open
898ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
14598
Junction 14598 (degree 1) lies on pipe 91552-8 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (42 m).
→ Split pipe 91552-8 at junction 14598 so both are connected.
Open
899ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
14601
Junction 14601 (degree 1) lies on pipe 91552-8 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (21 m).
→ Split pipe 91552-8 at junction 14601 so both are connected.
Open
900ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
14603
Junction 14603 (degree 1) lies on pipe 91552-8 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (32 m).
→ Split pipe 91552-8 at junction 14603 so both are connected.
Open
901ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
14606
Junction 14606 (degree 1) lies on pipe 91552-6 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (25 m).
→ Split pipe 91552-6 at junction 14606 so both are connected.
Open
902ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
14607
Junction 14607 (degree 1) lies on pipe 91552-6 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 91552-6 at junction 14607 so both are connected.
Open
903ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
14609
Junction 14609 (degree 1) lies on pipe 91552-6 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 91552-6 at junction 14609 so both are connected.
Open
904ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
14611
Junction 14611 (degree 1) lies on pipe 56423-6 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 56423-6 at junction 14611 so both are connected.
Open
905ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
20311
Junction 20311 (degree 1) lies on pipe 95548 (DN 355, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 95548 at junction 20311 so both are connected.
Open
906ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
25135
Junction 25135 (degree 1) lies on pipe 56568 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56568 at junction 25135 so both are connected.
Open
907ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3018
Junction 3018 (degree 1) lies on pipe 56682-7 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 56682-7 at junction 3018 so both are connected.
Open
908ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3027
Junction 3027 (degree 1) lies on pipe 65711-3 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 65711-3 at junction 3027 so both are connected.
Open
909ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3029
Junction 3029 (degree 1) lies on pipe 65711-3 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 65711-3 at junction 3029 so both are connected.
Open
910ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3034
Junction 3034 (degree 1) lies on pipe 56462 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (68 m).
→ Split pipe 56462 at junction 3034 so both are connected.
Open
911ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3044
Junction 3044 (degree 1) lies on pipe 56681-14 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56681-14 at junction 3044 so both are connected.
Open
912ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3045
Junction 3045 (degree 1) lies on pipe 56674-1 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56674-1 at junction 3045 so both are connected.
Open
913ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3046
Junction 3046 (degree 1) lies on pipe 56674-1 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 56674-1 at junction 3046 so both are connected.
Open
914ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3047
Junction 3047 (degree 1) lies on pipe 85842 (distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (20 m).
→ Split pipe 85842 at junction 3047 so both are connected.
Open
915ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3048
Junction 3048 (degree 1) lies on pipe 85842 (distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 85842 at junction 3048 so both are connected.
Open
916ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3049
Junction 3049 (degree 1) lies on pipe 85842 (distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 85842 at junction 3049 so both are connected.
Open
917ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3050
Junction 3050 (degree 1) lies on pipe 85842 (distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 85842 at junction 3050 so both are connected.
Open
918ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3051
Junction 3051 (degree 1) lies on pipe 85842 (distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 85842 at junction 3051 so both are connected.
Open
919ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3052
Junction 3052 (degree 1) lies on pipe 85842 (distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (23 m).
→ Split pipe 85842 at junction 3052 so both are connected.
Open
920ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3053
Junction 3053 (degree 1) lies on pipe 85840 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Split pipe 85840 at junction 3053 so both are connected.
Open
921ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3056
Junction 3056 (degree 1) lies on pipe 85840 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Split pipe 85840 at junction 3056 so both are connected.
Open
922ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3292
Junction 3292 (degree 1) lies on pipe 56681-2 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56681-2 at junction 3292 so both are connected.
Open
923ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
33398
Junction 33398 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 89724 at junction 33398 so both are connected.
Open
924ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
7729
Junction 7729 (degree 1) lies on pipe 89340-2 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 89340-2 at junction 7729 so both are connected.
Open
925ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
77385
Junction 77385 (degree 1) lies on pipe 89535-4 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 89535-4 at junction 77385 so both are connected.
Open
926ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
7758
Junction 7758 (degree 1) lies on pipe 89337 (DN 125, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Split pipe 89337 at junction 7758 so both are connected.
Open
927ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
7760
Junction 7760 (degree 1) lies on pipe 89125 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Split pipe 89125 at junction 7760 so both are connected.
Open
928ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
77669
Junction 77669 (degree 1) lies on pipe 89566-5 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 89566-5 at junction 77669 so both are connected.
Open
929ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
7778
Junction 7778 (degree 1) lies on pipe 89355 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 89355 at junction 7778 so both are connected.
Open
930ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
78416
Junction 78416 (degree 1) lies on pipe 89488-13 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 89488-13 at junction 78416 so both are connected.
Open
931ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
78531
Junction 78531 (degree 1) lies on pipe 89472-4 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Split pipe 89472-4 at junction 78531 so both are connected.
Open
932ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
78754
Junction 78754 (degree 1) lies on pipe 89470-6 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 89470-6 at junction 78754 so both are connected.
Open
933ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8198
Junction 8198 (degree 1) lies on pipe 53700 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 53700 at junction 8198 so both are connected.
Open
934ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8199
Junction 8199 (degree 1) lies on pipe 89381-1 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 89381-1 at junction 8199 so both are connected.
Open
935ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8520
Junction 8520 (degree 1) lies on pipe 56635-6 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 56635-6 at junction 8520 so both are connected.
Open
936ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8550
Junction 8550 (degree 1) lies on pipe 56366-2 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Split pipe 56366-2 at junction 8550 so both are connected.
Open
937ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8582
Junction 8582 (degree 1) lies on pipe 89488-15 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 89488-15 at junction 8582 so both are connected.
Open
938ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8585
Junction 8585 (degree 1) lies on pipe 89488-14 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 89488-14 at junction 8585 so both are connected.
Open
939ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8621
Junction 8621 (degree 1) lies on pipe 56633-19 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 56633-19 at junction 8621 so both are connected.
Open
940ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8665
Junction 8665 (degree 1) lies on pipe 56672-1 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 56672-1 at junction 8665 so both are connected.
Open
941ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86652
Junction 86652 (degree 1) lies on pipe 56571 (DN 25, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56571 at junction 86652 so both are connected.
Open
942ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86654
Junction 86654 (degree 1) lies on pipe 56588 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56588 at junction 86654 so both are connected.
Open
943ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86662
Junction 86662 (degree 1) lies on pipe 56588 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 56588 at junction 86662 so both are connected.
Open
944ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8668
Junction 8668 (degree 1) lies on pipe 56672-1 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (21 m).
→ Split pipe 56672-1 at junction 8668 so both are connected.
Open
945ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86719
Junction 86719 (degree 1) lies on pipe 52834-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52834-2 at junction 86719 so both are connected.
Open
946ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86723
Junction 86723 (degree 1) lies on pipe 52834-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52834-2 at junction 86723 so both are connected.
Open
947ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86725
Junction 86725 (degree 1) lies on pipe 52834-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52834-2 at junction 86725 so both are connected.
Open
948ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86727
Junction 86727 (degree 1) lies on pipe 52834-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52834-2 at junction 86727 so both are connected.
Open
949ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86735
Junction 86735 (degree 1) lies on pipe 52834-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52834-2 at junction 86735 so both are connected.
Open
950ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86739
Junction 86739 (degree 1) lies on pipe 52834-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52834-2 at junction 86739 so both are connected.
Open
951ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86743
Junction 86743 (degree 1) lies on pipe 52834-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52834-2 at junction 86743 so both are connected.
Open
952ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86747
Junction 86747 (degree 1) lies on pipe 52834-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52834-2 at junction 86747 so both are connected.
Open
953ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86751
Junction 86751 (degree 1) lies on pipe 52834-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52834-2 at junction 86751 so both are connected.
Open
954ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86753
Junction 86753 (degree 1) lies on pipe 52833 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52833 at junction 86753 so both are connected.
Open
955ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86755
Junction 86755 (degree 1) lies on pipe 52833 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 52833 at junction 86755 so both are connected.
Open
956ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86757
Junction 86757 (degree 1) lies on pipe 52833 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 52833 at junction 86757 so both are connected.
Open
957ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86759
Junction 86759 (degree 1) lies on pipe 52833 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 52833 at junction 86759 so both are connected.
Open
958ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86761
Junction 86761 (degree 1) lies on pipe 52833 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52833 at junction 86761 so both are connected.
Open
959ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86763
Junction 86763 (degree 1) lies on pipe 52833 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52833 at junction 86763 so both are connected.
Open
960ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86765
Junction 86765 (degree 1) lies on pipe 52833 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52833 at junction 86765 so both are connected.
Open
961ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86767
Junction 86767 (degree 1) lies on pipe 52833 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52833 at junction 86767 so both are connected.
Open
962ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
86769
Junction 86769 (degree 1) lies on pipe 52833 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (19 m).
→ Split pipe 52833 at junction 86769 so both are connected.
Open
963ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87090
Junction 87090 (degree 1) lies on pipe 52835-3 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52835-3 at junction 87090 so both are connected.
Open
964ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87098
Junction 87098 (degree 1) lies on pipe 52835-3 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (30 m).
→ Split pipe 52835-3 at junction 87098 so both are connected.
Open
965ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87100
Junction 87100 (degree 1) lies on pipe 52835-3 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 52835-3 at junction 87100 so both are connected.
Open
966ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87102
Junction 87102 (degree 1) lies on pipe 52835-3 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52835-3 at junction 87102 so both are connected.
Open
967ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87104
Junction 87104 (degree 1) lies on pipe 52835-3 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52835-3 at junction 87104 so both are connected.
Open
968ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87108
Junction 87108 (degree 1) lies on pipe 52835-3 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 52835-3 at junction 87108 so both are connected.
Open
969ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87110
Junction 87110 (degree 1) lies on pipe 52835-3 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 52835-3 at junction 87110 so both are connected.
Open
970ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87112
Junction 87112 (degree 1) lies on pipe 52835-3 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (41 m).
→ Split pipe 52835-3 at junction 87112 so both are connected.
Open
971ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87118
Junction 87118 (degree 1) lies on pipe 52835-2 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52835-2 at junction 87118 so both are connected.
Open
972ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87120
Junction 87120 (degree 1) lies on pipe 52835-2 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (20 m).
→ Split pipe 52835-2 at junction 87120 so both are connected.
Open
973ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87122
Junction 87122 (degree 1) lies on pipe 52835-2 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52835-2 at junction 87122 so both are connected.
Open
974ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87126
Junction 87126 (degree 1) lies on pipe 52835-2 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 52835-2 at junction 87126 so both are connected.
Open
975ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87130
Junction 87130 (degree 1) lies on pipe 52835-1 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52835-1 at junction 87130 so both are connected.
Open
976ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87132
Junction 87132 (degree 1) lies on pipe 52835-2 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52835-2 at junction 87132 so both are connected.
Open
977ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87136
Junction 87136 (degree 1) lies on pipe 52835-3 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52835-3 at junction 87136 so both are connected.
Open
978ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87138
Junction 87138 (degree 1) lies on pipe 52835-3 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52835-3 at junction 87138 so both are connected.
Open
979ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87141
Junction 87141 (degree 1) lies on pipe 52835-3 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52835-3 at junction 87141 so both are connected.
Open
980ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87143
Junction 87143 (degree 1) lies on pipe 52835-3 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52835-3 at junction 87143 so both are connected.
Open
981ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87145
Junction 87145 (degree 1) lies on pipe 52835-3 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52835-3 at junction 87145 so both are connected.
Open
982ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87147
Junction 87147 (degree 1) lies on pipe 52835-3 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52835-3 at junction 87147 so both are connected.
Open
983ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87149
Junction 87149 (degree 1) lies on pipe 52831 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 52831 at junction 87149 so both are connected.
Open
984ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87159
Junction 87159 (degree 1) lies on pipe 52831 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52831 at junction 87159 so both are connected.
Open
985ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87161
Junction 87161 (degree 1) lies on pipe 52831 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52831 at junction 87161 so both are connected.
Open
986ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87163
Junction 87163 (degree 1) lies on pipe 52831 (DN 100, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52831 at junction 87163 so both are connected.
Open
987ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87189
Junction 87189 (degree 1) lies on pipe 56423-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56423-1 at junction 87189 so both are connected.
Open
988ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87199
Junction 87199 (degree 1) lies on pipe 56423-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56423-1 at junction 87199 so both are connected.
Open
989ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87201
Junction 87201 (degree 1) lies on pipe 56423-4 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56423-4 at junction 87201 so both are connected.
Open
990ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87203
Junction 87203 (degree 1) lies on pipe 56423-4 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56423-4 at junction 87203 so both are connected.
Open
991ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87205
Junction 87205 (degree 1) lies on pipe 56423-4 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56423-4 at junction 87205 so both are connected.
Open
992ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87207
Junction 87207 (degree 1) lies on pipe 56423-4 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56423-4 at junction 87207 so both are connected.
Open
993ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87209
Junction 87209 (degree 1) lies on pipe 56423-5 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56423-5 at junction 87209 so both are connected.
Open
994ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87211
Junction 87211 (degree 1) lies on pipe 56423-6 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56423-6 at junction 87211 so both are connected.
Open
995ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87213
Junction 87213 (degree 1) lies on pipe 56423-6 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56423-6 at junction 87213 so both are connected.
Open
996ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87215
Junction 87215 (degree 1) lies on pipe 56423-6 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56423-6 at junction 87215 so both are connected.
Open
997ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87217
Junction 87217 (degree 1) lies on pipe 56423-6 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56423-6 at junction 87217 so both are connected.
Open
998ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87219
Junction 87219 (degree 1) lies on pipe 56423-6 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (22 m).
→ Split pipe 56423-6 at junction 87219 so both are connected.
Open
999ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87221
Junction 87221 (degree 1) lies on pipe 56423-7 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56423-7 at junction 87221 so both are connected.
Open
1000ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87223
Junction 87223 (degree 1) lies on pipe 56423-8 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 56423-8 at junction 87223 so both are connected.
Open
1001ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87225
Junction 87225 (degree 1) lies on pipe 52827-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52827-1 at junction 87225 so both are connected.
Open
1002ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87227
Junction 87227 (degree 1) lies on pipe 52827-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52827-2 at junction 87227 so both are connected.
Open
1003ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87229
Junction 87229 (degree 1) lies on pipe 52827-3 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52827-3 at junction 87229 so both are connected.
Open
1004ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87231
Junction 87231 (degree 1) lies on pipe 52827-3 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52827-3 at junction 87231 so both are connected.
Open
1005ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87233
Junction 87233 (degree 1) lies on pipe 52827-4 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52827-4 at junction 87233 so both are connected.
Open
1006ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87235
Junction 87235 (degree 1) lies on pipe 52827-5 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52827-5 at junction 87235 so both are connected.
Open
1007ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87237
Junction 87237 (degree 1) lies on pipe 52827-8 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52827-8 at junction 87237 so both are connected.
Open
1008ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87239
Junction 87239 (degree 1) lies on pipe 52827-8 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 52827-8 at junction 87239 so both are connected.
Open
1009ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87241
Junction 87241 (degree 1) lies on pipe 52827-8 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52827-8 at junction 87241 so both are connected.
Open
1010ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87243
Junction 87243 (degree 1) lies on pipe 52827-8 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52827-8 at junction 87243 so both are connected.
Open
1011ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87245
Junction 87245 (degree 1) lies on pipe 52827-8 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52827-8 at junction 87245 so both are connected.
Open
1012ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87247
Junction 87247 (degree 1) lies on pipe 52827-9 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52827-9 at junction 87247 so both are connected.
Open
1013ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87289
Junction 87289 (degree 1) lies on pipe 56568 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56568 at junction 87289 so both are connected.
Open
1014ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87293
Junction 87293 (degree 1) lies on pipe 56568 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56568 at junction 87293 so both are connected.
Open
1015ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87303
Junction 87303 (degree 1) lies on pipe 56568 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (30 m).
→ Split pipe 56568 at junction 87303 so both are connected.
Open
1016ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87305
Junction 87305 (degree 1) lies on pipe 56572 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56572 at junction 87305 so both are connected.
Open
1017ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87308
Junction 87308 (degree 1) lies on pipe 56572 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56572 at junction 87308 so both are connected.
Open
1018ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87313
Junction 87313 (degree 1) lies on pipe 56568 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56568 at junction 87313 so both are connected.
Open
1019ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87316
Junction 87316 (degree 1) lies on pipe 56568 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56568 at junction 87316 so both are connected.
Open
1020ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87318
Junction 87318 (degree 1) lies on pipe 52827-10 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52827-10 at junction 87318 so both are connected.
Open
1021ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87320
Junction 87320 (degree 1) lies on pipe 52827-9 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52827-9 at junction 87320 so both are connected.
Open
1022ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87429
Junction 87429 (degree 1) lies on pipe 56417 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56417 at junction 87429 so both are connected.
Open
1023ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87431
Junction 87431 (degree 1) lies on pipe 56417 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56417 at junction 87431 so both are connected.
Open
1024ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87433
Junction 87433 (degree 1) lies on pipe 56417 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (17 m).
→ Split pipe 56417 at junction 87433 so both are connected.
Open
1025ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87435
Junction 87435 (degree 1) lies on pipe 56417 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (19 m).
→ Split pipe 56417 at junction 87435 so both are connected.
Open
1026ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87439
Junction 87439 (degree 1) lies on pipe 56417 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 56417 at junction 87439 so both are connected.
Open
1027ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87441
Junction 87441 (degree 1) lies on pipe 56417 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56417 at junction 87441 so both are connected.
Open
1028ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87444
Junction 87444 (degree 1) lies on pipe 56417 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56417 at junction 87444 so both are connected.
Open
1029ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87446
Junction 87446 (degree 1) lies on pipe 56417 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (19 m).
→ Split pipe 56417 at junction 87446 so both are connected.
Open
1030ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87448
Junction 87448 (degree 1) lies on pipe 56417 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56417 at junction 87448 so both are connected.
Open
1031ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87450
Junction 87450 (degree 1) lies on pipe 56417 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 56417 at junction 87450 so both are connected.
Open
1032ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87452
Junction 87452 (degree 1) lies on pipe 56416-2 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56416-2 at junction 87452 so both are connected.
Open
1033ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87454
Junction 87454 (degree 1) lies on pipe 56417 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (17 m).
→ Split pipe 56417 at junction 87454 so both are connected.
Open
1034ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87458
Junction 87458 (degree 1) lies on pipe 56417 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (27 m).
→ Split pipe 56417 at junction 87458 so both are connected.
Open
1035ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87460
Junction 87460 (degree 1) lies on pipe 56416-1 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 56416-1 at junction 87460 so both are connected.
Open
1036ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87463
Junction 87463 (degree 1) lies on pipe 56416-1 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56416-1 at junction 87463 so both are connected.
Open
1037ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87465
Junction 87465 (degree 1) lies on pipe 56416-1 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 56416-1 at junction 87465 so both are connected.
Open
1038ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87470
Junction 87470 (degree 1) lies on pipe 56416-1 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56416-1 at junction 87470 so both are connected.
Open
1039ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87472
Junction 87472 (degree 1) lies on pipe 56416-1 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56416-1 at junction 87472 so both are connected.
Open
1040ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87474
Junction 87474 (degree 1) lies on pipe 56416-1 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56416-1 at junction 87474 so both are connected.
Open
1041ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87482
Junction 87482 (degree 1) lies on pipe 52823 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52823 at junction 87482 so both are connected.
Open
1042ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87488
Junction 87488 (degree 1) lies on pipe 56417 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56417 at junction 87488 so both are connected.
Open
1043ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87490
Junction 87490 (degree 1) lies on pipe 52823 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52823 at junction 87490 so both are connected.
Open
1044ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87492
Junction 87492 (degree 1) lies on pipe 52823 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52823 at junction 87492 so both are connected.
Open
1045ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87494
Junction 87494 (degree 1) lies on pipe 52823 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (17 m).
→ Split pipe 52823 at junction 87494 so both are connected.
Open
1046ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87496
Junction 87496 (degree 1) lies on pipe 52823 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (27 m).
→ Split pipe 52823 at junction 87496 so both are connected.
Open
1047ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87498
Junction 87498 (degree 1) lies on pipe 52823 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 52823 at junction 87498 so both are connected.
Open
1048ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87509
Junction 87509 (degree 1) lies on pipe 52822-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 52822-2 at junction 87509 so both are connected.
Open
1049ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87511
Junction 87511 (degree 1) lies on pipe 52822-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 52822-2 at junction 87511 so both are connected.
Open
1050ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87513
Junction 87513 (degree 1) lies on pipe 52822-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Split pipe 52822-2 at junction 87513 so both are connected.
Open
1051ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87515
Junction 87515 (degree 1) lies on pipe 52822-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (41 m).
→ Split pipe 52822-2 at junction 87515 so both are connected.
Open
1052ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87519
Junction 87519 (degree 1) lies on pipe 52822-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (17 m).
→ Split pipe 52822-2 at junction 87519 so both are connected.
Open
1053ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87521
Junction 87521 (degree 1) lies on pipe 52822-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 52822-2 at junction 87521 so both are connected.
Open
1054ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87523
Junction 87523 (degree 1) lies on pipe 52822-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 52822-2 at junction 87523 so both are connected.
Open
1055ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87526
Junction 87526 (degree 1) lies on pipe 52822-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (27 m).
→ Split pipe 52822-2 at junction 87526 so both are connected.
Open
1056ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87530
Junction 87530 (degree 1) lies on pipe 52822-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (22 m).
→ Split pipe 52822-2 at junction 87530 so both are connected.
Open
1057ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87536
Junction 87536 (degree 1) lies on pipe 52822-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (21 m).
→ Split pipe 52822-1 at junction 87536 so both are connected.
Open
1058ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87541
Junction 87541 (degree 1) lies on pipe 52822-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (17 m).
→ Split pipe 52822-1 at junction 87541 so both are connected.
Open
1059ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87552
Junction 87552 (degree 1) lies on pipe 52821 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (26 m).
→ Split pipe 52821 at junction 87552 so both are connected.
Open
1060ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87557
Junction 87557 (degree 1) lies on pipe 52822-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Split pipe 52822-1 at junction 87557 so both are connected.
Open
1061ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87559
Junction 87559 (degree 1) lies on pipe 52822-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (33 m).
→ Split pipe 52822-1 at junction 87559 so both are connected.
Open
1062ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87561
Junction 87561 (degree 1) lies on pipe 52820-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 52820-2 at junction 87561 so both are connected.
Open
1063ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87563
Junction 87563 (degree 1) lies on pipe 52822-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (17 m).
→ Split pipe 52822-1 at junction 87563 so both are connected.
Open
1064ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87567
Junction 87567 (degree 1) lies on pipe 52821 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Split pipe 52821 at junction 87567 so both are connected.
Open
1065ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87570
Junction 87570 (degree 1) lies on pipe 52820-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 52820-2 at junction 87570 so both are connected.
Open
1066ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87572
Junction 87572 (degree 1) lies on pipe 52820-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 52820-2 at junction 87572 so both are connected.
Open
1067ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87574
Junction 87574 (degree 1) lies on pipe 52820-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 52820-2 at junction 87574 so both are connected.
Open
1068ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87576
Junction 87576 (degree 1) lies on pipe 52820-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (17 m).
→ Split pipe 52820-2 at junction 87576 so both are connected.
Open
1069ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87578
Junction 87578 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52820-1 at junction 87578 so both are connected.
Open
1070ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87580
Junction 87580 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52820-1 at junction 87580 so both are connected.
Open
1071ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87582
Junction 87582 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52820-1 at junction 87582 so both are connected.
Open
1072ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87584
Junction 87584 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52820-1 at junction 87584 so both are connected.
Open
1073ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87586
Junction 87586 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52820-1 at junction 87586 so both are connected.
Open
1074ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87588
Junction 87588 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52820-1 at junction 87588 so both are connected.
Open
1075ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87590
Junction 87590 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52820-1 at junction 87590 so both are connected.
Open
1076ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87592
Junction 87592 (degree 1) lies on pipe 52820-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 52820-2 at junction 87592 so both are connected.
Open
1077ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87594
Junction 87594 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 52820-1 at junction 87594 so both are connected.
Open
1078ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87596
Junction 87596 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 52820-1 at junction 87596 so both are connected.
Open
1079ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87598
Junction 87598 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 52820-1 at junction 87598 so both are connected.
Open
1080ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87600
Junction 87600 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 52820-1 at junction 87600 so both are connected.
Open
1081ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87606
Junction 87606 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52820-1 at junction 87606 so both are connected.
Open
1082ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87608
Junction 87608 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52820-1 at junction 87608 so both are connected.
Open
1083ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87610
Junction 87610 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52820-1 at junction 87610 so both are connected.
Open
1084ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87614
Junction 87614 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 52820-1 at junction 87614 so both are connected.
Open
1085ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87619
Junction 87619 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52820-1 at junction 87619 so both are connected.
Open
1086ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87621
Junction 87621 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52820-1 at junction 87621 so both are connected.
Open
1087ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87624
Junction 87624 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (17 m).
→ Split pipe 52820-1 at junction 87624 so both are connected.
Open
1088ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87628
Junction 87628 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52820-1 at junction 87628 so both are connected.
Open
1089ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87630
Junction 87630 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52820-1 at junction 87630 so both are connected.
Open
1090ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87633
Junction 87633 (degree 1) lies on pipe 52820-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52820-1 at junction 87633 so both are connected.
Open
1091ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87637
Junction 87637 (degree 1) lies on pipe 52817 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52817 at junction 87637 so both are connected.
Open
1092ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87639
Junction 87639 (degree 1) lies on pipe 52817 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52817 at junction 87639 so both are connected.
Open
1093ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87641
Junction 87641 (degree 1) lies on pipe 56387 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (19 m).
→ Split pipe 56387 at junction 87641 so both are connected.
Open
1094ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87643
Junction 87643 (degree 1) lies on pipe 52819 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Split pipe 52819 at junction 87643 so both are connected.
Open
1095ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87645
Junction 87645 (degree 1) lies on pipe 52817 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52817 at junction 87645 so both are connected.
Open
1096ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87647
Junction 87647 (degree 1) lies on pipe 52817 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52817 at junction 87647 so both are connected.
Open
1097ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87649
Junction 87649 (degree 1) lies on pipe 52817 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52817 at junction 87649 so both are connected.
Open
1098ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87651
Junction 87651 (degree 1) lies on pipe 52817 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52817 at junction 87651 so both are connected.
Open
1099ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87653
Junction 87653 (degree 1) lies on pipe 52817 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (29 m).
→ Split pipe 52817 at junction 87653 so both are connected.
Open
1100ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87655
Junction 87655 (degree 1) lies on pipe 52817 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52817 at junction 87655 so both are connected.
Open
1101ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87657
Junction 87657 (degree 1) lies on pipe 52918 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52918 at junction 87657 so both are connected.
Open
1102ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87659
Junction 87659 (degree 1) lies on pipe 52918 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52918 at junction 87659 so both are connected.
Open
1103ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87661
Junction 87661 (degree 1) lies on pipe 52918 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 52918 at junction 87661 so both are connected.
Open
1104ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87663
Junction 87663 (degree 1) lies on pipe 52918 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52918 at junction 87663 so both are connected.
Open
1105ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87665
Junction 87665 (degree 1) lies on pipe 52918 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52918 at junction 87665 so both are connected.
Open
1106ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87667
Junction 87667 (degree 1) lies on pipe 52918 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52918 at junction 87667 so both are connected.
Open
1107ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87671
Junction 87671 (degree 1) lies on pipe 52918 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52918 at junction 87671 so both are connected.
Open
1108ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87675
Junction 87675 (degree 1) lies on pipe 52918 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52918 at junction 87675 so both are connected.
Open
1109ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87679
Junction 87679 (degree 1) lies on pipe 52918 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52918 at junction 87679 so both are connected.
Open
1110ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87687
Junction 87687 (degree 1) lies on pipe 52918 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 52918 at junction 87687 so both are connected.
Open
1111ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87689
Junction 87689 (degree 1) lies on pipe 56384 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56384 at junction 87689 so both are connected.
Open
1112ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87691
Junction 87691 (degree 1) lies on pipe 56384 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 56384 at junction 87691 so both are connected.
Open
1113ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87693
Junction 87693 (degree 1) lies on pipe 56384 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56384 at junction 87693 so both are connected.
Open
1114ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87697
Junction 87697 (degree 1) lies on pipe 56384 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (17 m).
→ Split pipe 56384 at junction 87697 so both are connected.
Open
1115ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87699
Junction 87699 (degree 1) lies on pipe 56384 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56384 at junction 87699 so both are connected.
Open
1116ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87701
Junction 87701 (degree 1) lies on pipe 56384 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56384 at junction 87701 so both are connected.
Open
1117ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87703
Junction 87703 (degree 1) lies on pipe 56384 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56384 at junction 87703 so both are connected.
Open
1118ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87705
Junction 87705 (degree 1) lies on pipe 56384 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (28 m).
→ Split pipe 56384 at junction 87705 so both are connected.
Open
1119ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87707
Junction 87707 (degree 1) lies on pipe 56384 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56384 at junction 87707 so both are connected.
Open
1120ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87709
Junction 87709 (degree 1) lies on pipe 56384 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56384 at junction 87709 so both are connected.
Open
1121ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87711
Junction 87711 (degree 1) lies on pipe 53735 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 53735 at junction 87711 so both are connected.
Open
1122ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87930
Junction 87930 (degree 1) lies on pipe 56576 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56576 at junction 87930 so both are connected.
Open
1123ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87932
Junction 87932 (degree 1) lies on pipe 56576 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56576 at junction 87932 so both are connected.
Open
1124ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87934
Junction 87934 (degree 1) lies on pipe 56576 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56576 at junction 87934 so both are connected.
Open
1125ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87936
Junction 87936 (degree 1) lies on pipe 56576 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56576 at junction 87936 so both are connected.
Open
1126ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
87938
Junction 87938 (degree 1) lies on pipe 56576 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (22 m).
→ Split pipe 56576 at junction 87938 so both are connected.
Open
1127ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88122
Junction 88122 (degree 1) lies on pipe 56561 (DN 25, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 56561 at junction 88122 so both are connected.
Open
1128ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88369
Junction 88369 (degree 1) lies on pipe 52832-1 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52832-1 at junction 88369 so both are connected.
Open
1129ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88371
Junction 88371 (degree 1) lies on pipe 52832-1 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52832-1 at junction 88371 so both are connected.
Open
1130ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88373
Junction 88373 (degree 1) lies on pipe 52832-1 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52832-1 at junction 88373 so both are connected.
Open
1131ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88375
Junction 88375 (degree 1) lies on pipe 52832-1 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 52832-1 at junction 88375 so both are connected.
Open
1132ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88377
Junction 88377 (degree 1) lies on pipe 52832-1 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52832-1 at junction 88377 so both are connected.
Open
1133ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88379
Junction 88379 (degree 1) lies on pipe 52832-1 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52832-1 at junction 88379 so both are connected.
Open
1134ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88381
Junction 88381 (degree 1) lies on pipe 52832-1 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52832-1 at junction 88381 so both are connected.
Open
1135ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88383
Junction 88383 (degree 1) lies on pipe 52832-2 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52832-2 at junction 88383 so both are connected.
Open
1136ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88389
Junction 88389 (degree 1) lies on pipe 56415 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56415 at junction 88389 so both are connected.
Open
1137ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88391
Junction 88391 (degree 1) lies on pipe 56415 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 56415 at junction 88391 so both are connected.
Open
1138ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88395
Junction 88395 (degree 1) lies on pipe 56415 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Split pipe 56415 at junction 88395 so both are connected.
Open
1139ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88397
Junction 88397 (degree 1) lies on pipe 56415 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 56415 at junction 88397 so both are connected.
Open
1140ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88399
Junction 88399 (degree 1) lies on pipe 56415 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56415 at junction 88399 so both are connected.
Open
1141ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88402
Junction 88402 (degree 1) lies on pipe 56415 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56415 at junction 88402 so both are connected.
Open
1142ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88410
Junction 88410 (degree 1) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56414 at junction 88410 so both are connected.
Open
1143ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88414
Junction 88414 (degree 1) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56414 at junction 88414 so both are connected.
Open
1144ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88416
Junction 88416 (degree 1) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56414 at junction 88416 so both are connected.
Open
1145ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88420
Junction 88420 (degree 1) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 56414 at junction 88420 so both are connected.
Open
1146ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88423
Junction 88423 (degree 1) lies on pipe 56415 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 56415 at junction 88423 so both are connected.
Open
1147ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88426
Junction 88426 (degree 1) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 56414 at junction 88426 so both are connected.
Open
1148ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88429
Junction 88429 (degree 1) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 56414 at junction 88429 so both are connected.
Open
1149ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8843
Junction 8843 (degree 1) lies on pipe 89524-23 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 89524-23 at junction 8843 so both are connected.
Open
1150ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88431
Junction 88431 (degree 1) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 56414 at junction 88431 so both are connected.
Open
1151ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88434
Junction 88434 (degree 1) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 56414 at junction 88434 so both are connected.
Open
1152ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88436
Junction 88436 (degree 1) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 56414 at junction 88436 so both are connected.
Open
1153ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88439
Junction 88439 (degree 1) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 56414 at junction 88439 so both are connected.
Open
1154ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88441
Junction 88441 (degree 1) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 56414 at junction 88441 so both are connected.
Open
1155ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88443
Junction 88443 (degree 1) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 56414 at junction 88443 so both are connected.
Open
1156ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88445
Junction 88445 (degree 1) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56414 at junction 88445 so both are connected.
Open
1157ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88447
Junction 88447 (degree 1) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 56414 at junction 88447 so both are connected.
Open
1158ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88449
Junction 88449 (degree 1) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56414 at junction 88449 so both are connected.
Open
1159ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88451
Junction 88451 (degree 1) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (19 m).
→ Split pipe 56414 at junction 88451 so both are connected.
Open
1160ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88453
Junction 88453 (degree 1) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 56414 at junction 88453 so both are connected.
Open
1161ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88455
Junction 88455 (degree 1) lies on pipe 56414 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 56414 at junction 88455 so both are connected.
Open
1162ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8851
Junction 8851 (degree 1) lies on pipe 89524-22 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 89524-22 at junction 8851 so both are connected.
Open
1163ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8854
Junction 8854 (degree 1) lies on pipe 89524-15 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 89524-15 at junction 8854 so both are connected.
Open
1164ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8856
Junction 8856 (degree 1) lies on pipe 89524-17 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Split pipe 89524-17 at junction 8856 so both are connected.
Open
1165ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8865
Junction 8865 (degree 1) lies on pipe 89524-13 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 89524-13 at junction 8865 so both are connected.
Open
1166ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88725
Junction 88725 (degree 1) lies on pipe 52895 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52895 at junction 88725 so both are connected.
Open
1167ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88730
Junction 88730 (degree 1) lies on pipe 52895 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 52895 at junction 88730 so both are connected.
Open
1168ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88732
Junction 88732 (degree 1) lies on pipe 52895 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 52895 at junction 88732 so both are connected.
Open
1169ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88738
Junction 88738 (degree 1) lies on pipe 52895 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52895 at junction 88738 so both are connected.
Open
1170ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88746
Junction 88746 (degree 1) lies on pipe 52895 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52895 at junction 88746 so both are connected.
Open
1171ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88748
Junction 88748 (degree 1) lies on pipe 52895 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52895 at junction 88748 so both are connected.
Open
1172ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88752
Junction 88752 (degree 1) lies on pipe 52895 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (26 m).
→ Split pipe 52895 at junction 88752 so both are connected.
Open
1173ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88755
Junction 88755 (degree 1) lies on pipe 52895 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (17 m).
→ Split pipe 52895 at junction 88755 so both are connected.
Open
1174ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88757
Junction 88757 (degree 1) lies on pipe 52895 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 52895 at junction 88757 so both are connected.
Open
1175ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88759
Junction 88759 (degree 1) lies on pipe 52895 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Split pipe 52895 at junction 88759 so both are connected.
Open
1176ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88761
Junction 88761 (degree 1) lies on pipe 52894 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 52894 at junction 88761 so both are connected.
Open
1177ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
88791
Junction 88791 (degree 1) lies on pipe 52894 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 52894 at junction 88791 so both are connected.
Open
1178ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89008
Junction 89008 (degree 1) lies on pipe 56368 (distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56368 at junction 89008 so both are connected.
Open
1179ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89010
Junction 89010 (degree 1) lies on pipe 56368 (distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 56368 at junction 89010 so both are connected.
Open
1180ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89012
Junction 89012 (degree 1) lies on pipe 56368 (distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 56368 at junction 89012 so both are connected.
Open
1181ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89014
Junction 89014 (degree 1) lies on pipe 56368 (distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56368 at junction 89014 so both are connected.
Open
1182ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89026
Junction 89026 (degree 1) lies on pipe 52823 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 52823 at junction 89026 so both are connected.
Open
1183ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89036
Junction 89036 (degree 1) lies on pipe 89381-1 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (26 m).
→ Split pipe 89381-1 at junction 89036 so both are connected.
Open
1184ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89068
Junction 89068 (degree 1) lies on pipe 56568 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (25 m).
→ Split pipe 56568 at junction 89068 so both are connected.
Open
1185ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89091
Junction 89091 (degree 1) lies on pipe 52822-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 52822-2 at junction 89091 so both are connected.
Open
1186ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89093
Junction 89093 (degree 1) lies on pipe 52822-1 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (39 m).
→ Split pipe 52822-1 at junction 89093 so both are connected.
Open
1187ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89228
Junction 89228 (degree 1) lies on pipe 52836 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 52836 at junction 89228 so both are connected.
Open
1188ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89231
Junction 89231 (degree 1) lies on pipe 52832-1 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 52832-1 at junction 89231 so both are connected.
Open
1189ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89233
Junction 89233 (degree 1) lies on pipe 52832-1 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 52832-1 at junction 89233 so both are connected.
Open
1190ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89268
Junction 89268 (degree 1) lies on pipe 52895 (DN 200, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 52895 at junction 89268 so both are connected.
Open
1191ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89314
Junction 89314 (degree 1) lies on pipe 52819 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (34 m).
→ Split pipe 52819 at junction 89314 so both are connected.
Open
1192ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89316
Junction 89316 (degree 1) lies on pipe 52823 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52823 at junction 89316 so both are connected.
Open
1193ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89328
Junction 89328 (degree 1) lies on pipe 56384 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (23 m).
→ Split pipe 56384 at junction 89328 so both are connected.
Open
1194ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89330
Junction 89330 (degree 1) lies on pipe 56384 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (52 m).
→ Split pipe 56384 at junction 89330 so both are connected.
Open
1195ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89332
Junction 89332 (degree 1) lies on pipe 56384 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56384 at junction 89332 so both are connected.
Open
1196ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89334
Junction 89334 (degree 1) lies on pipe 53735 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (47 m).
→ Split pipe 53735 at junction 89334 so both are connected.
Open
1197ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89336
Junction 89336 (degree 1) lies on pipe 53737 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 53737 at junction 89336 so both are connected.
Open
1198ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89338
Junction 89338 (degree 1) lies on pipe 53736 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (25 m).
→ Split pipe 53736 at junction 89338 so both are connected.
Open
1199ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89340
Junction 89340 (degree 1) lies on pipe 53736 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (21 m).
→ Split pipe 53736 at junction 89340 so both are connected.
Open
1200ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89342
Junction 89342 (degree 1) lies on pipe 53736 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (22 m).
→ Split pipe 53736 at junction 89342 so both are connected.
Open
1201ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89469
Junction 89469 (degree 1) lies on pipe 56588 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 56588 at junction 89469 so both are connected.
Open
1202ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89471
Junction 89471 (degree 1) lies on pipe 56588 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 56588 at junction 89471 so both are connected.
Open
1203ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89489
Junction 89489 (degree 1) lies on pipe 89381-1 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (21 m).
→ Split pipe 89381-1 at junction 89489 so both are connected.
Open
1204ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89605
Junction 89605 (degree 1) lies on pipe 52822-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52822-2 at junction 89605 so both are connected.
Open
1205ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89609
Junction 89609 (degree 1) lies on pipe 53735 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 53735 at junction 89609 so both are connected.
Open
1206ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89611
Junction 89611 (degree 1) lies on pipe 52823 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 52823 at junction 89611 so both are connected.
Open
1207ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89621
Junction 89621 (degree 1) lies on pipe 56486 (DN 32, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (23 m).
→ Split pipe 56486 at junction 89621 so both are connected.
Open
1208ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89623
Junction 89623 (degree 1) lies on pipe 56487 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 56487 at junction 89623 so both are connected.
Open
1209ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89649
Junction 89649 (degree 1) lies on pipe 52740 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 52740 at junction 89649 so both are connected.
Open
1210ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89651
Junction 89651 (degree 1) lies on pipe 52740 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52740 at junction 89651 so both are connected.
Open
1211ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89653
Junction 89653 (degree 1) lies on pipe 52740 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52740 at junction 89653 so both are connected.
Open
1212ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89654
Junction 89654 (degree 1) lies on pipe 52740 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 52740 at junction 89654 so both are connected.
Open
1213ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89658
Junction 89658 (degree 1) lies on pipe 56487 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56487 at junction 89658 so both are connected.
Open
1214ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89660
Junction 89660 (degree 1) lies on pipe 56487 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56487 at junction 89660 so both are connected.
Open
1215ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89662
Junction 89662 (degree 1) lies on pipe 56487 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56487 at junction 89662 so both are connected.
Open
1216ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89664
Junction 89664 (degree 1) lies on pipe 56487 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Split pipe 56487 at junction 89664 so both are connected.
Open
1217ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89666
Junction 89666 (degree 1) lies on pipe 56487 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56487 at junction 89666 so both are connected.
Open
1218ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89668
Junction 89668 (degree 1) lies on pipe 56487 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56487 at junction 89668 so both are connected.
Open
1219ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89670
Junction 89670 (degree 1) lies on pipe 56487 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 56487 at junction 89670 so both are connected.
Open
1220ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89672
Junction 89672 (degree 1) lies on pipe 56487 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (20 m).
→ Split pipe 56487 at junction 89672 so both are connected.
Open
1221ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89674
Junction 89674 (degree 1) lies on pipe 56487 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56487 at junction 89674 so both are connected.
Open
1222ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89676
Junction 89676 (degree 1) lies on pipe 56487 (DN 40, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56487 at junction 89676 so both are connected.
Open
1223ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89708
Junction 89708 (degree 1) lies on pipe 56391 (DN 80, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (82 m).
→ Split pipe 56391 at junction 89708 so both are connected.
Open
1224ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89782
Junction 89782 (degree 1) lies on pipe 52834-2 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 52834-2 at junction 89782 so both are connected.
Open
1225ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89799
Junction 89799 (degree 1) lies on pipe 56366-1 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (42 m).
→ Split pipe 56366-1 at junction 89799 so both are connected.
Open
1226ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89802
Junction 89802 (degree 1) lies on pipe 56366-1 (DN 90, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (28 m).
→ Split pipe 56366-1 at junction 89802 so both are connected.
Open
1227ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9723
Junction 9723 (degree 1) lies on pipe 89723-3 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 89723-3 at junction 9723 so both are connected.
Open
1228ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9724
Junction 9724 (degree 1) lies on pipe 99702-1 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 99702-1 at junction 9724 so both are connected.
Open
1229ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9726
Junction 9726 (degree 1) lies on pipe 99702-1 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 99702-1 at junction 9726 so both are connected.
Open
1230ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9727
Junction 9727 (degree 1) lies on pipe 99702-2 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Split pipe 99702-2 at junction 9727 so both are connected.
Open
1231ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9731
Junction 9731 (degree 1) lies on pipe 99702-3 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 99702-3 at junction 9731 so both are connected.
Open
1232ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9732
Junction 9732 (degree 1) lies on pipe 99702-3 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 99702-3 at junction 9732 so both are connected.
Open
1233ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9733
Junction 9733 (degree 1) lies on pipe 89723-2 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (15 m).
→ Split pipe 89723-2 at junction 9733 so both are connected.
Open
1234ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9734
Junction 9734 (degree 1) lies on pipe 89723-2 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 89723-2 at junction 9734 so both are connected.
Open
1235ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9736
Junction 9736 (degree 1) lies on pipe 89723-5 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 89723-5 at junction 9736 so both are connected.
Open
1236ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9737
Junction 9737 (degree 1) lies on pipe 89723-3 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Split pipe 89723-3 at junction 9737 so both are connected.
Open
1237ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9740
Junction 9740 (degree 1) lies on pipe 89723-11 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 89723-11 at junction 9740 so both are connected.
Open
1238ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9746
Junction 9746 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 89724 at junction 9746 so both are connected.
Open
1239ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9747
Junction 9747 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 89724 at junction 9747 so both are connected.
Open
1240ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9762
Junction 9762 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 89724 at junction 9762 so both are connected.
Open
1241ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9769
Junction 9769 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 89724 at junction 9769 so both are connected.
Open
1242ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9771
Junction 9771 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 89724 at junction 9771 so both are connected.
Open
1243ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9773
Junction 9773 (degree 1) lies on pipe 89723-11 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 89723-11 at junction 9773 so both are connected.
Open
1244ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9791
Junction 9791 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 89724 at junction 9791 so both are connected.
Open
1245ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9794
Junction 9794 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 89724 at junction 9794 so both are connected.
Open
1246ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9796
Junction 9796 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 89724 at junction 9796 so both are connected.
Open
1247ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9798
Junction 9798 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 89724 at junction 9798 so both are connected.
Open
1248ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9800
Junction 9800 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 89724 at junction 9800 so both are connected.
Open
1249ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9802
Junction 9802 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 89724 at junction 9802 so both are connected.
Open
1250ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9804
Junction 9804 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 89724 at junction 9804 so both are connected.
Open
1251ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9806
Junction 9806 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 89724 at junction 9806 so both are connected.
Open
1252ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9808
Junction 9808 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 89724 at junction 9808 so both are connected.
Open
1253ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9812
Junction 9812 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 89724 at junction 9812 so both are connected.
Open
1254ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9814
Junction 9814 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 89724 at junction 9814 so both are connected.
Open
1255ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9820
Junction 9820 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 89724 at junction 9820 so both are connected.
Open
1256ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9822
Junction 9822 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 89724 at junction 9822 so both are connected.
Open
1257ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9824
Junction 9824 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 89724 at junction 9824 so both are connected.
Open
1258ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9826
Junction 9826 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Split pipe 89724 at junction 9826 so both are connected.
Open
1259ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9828
Junction 9828 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 89724 at junction 9828 so both are connected.
Open
1260ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9830
Junction 9830 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 89724 at junction 9830 so both are connected.
Open
1261ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9832
Junction 9832 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 89724 at junction 9832 so both are connected.
Open
1262ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9834
Junction 9834 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 89724 at junction 9834 so both are connected.
Open
1263ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9836
Junction 9836 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Split pipe 89724 at junction 9836 so both are connected.
Open
1264ERROR
P95
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9838
Junction 9838 (degree 1) lies on pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Split pipe 89724 at junction 9838 so both are connected.
Open
1265ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
14586
Junction 14586 (degree 1) is 0.28 m from pipe 91552-6 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Extend/snap to pipe 91552-6 and split it there, or confirm the gap is real.
Open
1266ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
14602
Junction 14602 (degree 1) is 0.09 m from pipe 52827-6 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Extend/snap to pipe 52827-6 and split it there, or confirm the gap is real.
Open
1267ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
14612
Junction 14612 (degree 1) is 0.10 m from pipe 91552-7 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Extend/snap to pipe 91552-7 and split it there, or confirm the gap is real.
Open
1268ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
14618
Junction 14618 (degree 1) is 0.06 m from pipe 52827-3 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Extend/snap to pipe 52827-3 and split it there, or confirm the gap is real.
Open
1269ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
3297
Junction 3297 (degree 1) is 0.45 m from pipe 56681-2 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Extend/snap to pipe 56681-2 and split it there, or confirm the gap is real.
Open
1270ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
72346
Junction 72346 (degree 1) is 0.07 m from pipe 89927 (DN 110, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (102 m).
→ Extend/snap to pipe 89927 and split it there, or confirm the gap is real.
Open
1271ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
75967
Junction 75967 (degree 1) is 0.70 m from pipe 56543 (DN 150, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Extend/snap to pipe 56543 and split it there, or confirm the gap is real.
Open
1272ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
75969
Junction 75969 (degree 1) is 0.73 m from pipe 56539 (distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Extend/snap to pipe 56539 and split it there, or confirm the gap is real.
Open
1273ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
86552
Junction 86552 (degree 1) is 0.71 m from pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Extend/snap to pipe 89724 and split it there, or confirm the gap is real.
Open
1274ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
86562
Junction 86562 (degree 1) is 0.85 m from pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Extend/snap to pipe 89724 and split it there, or confirm the gap is real.
Open
1275ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
87183
Junction 87183 (degree 1) is 0.82 m from pipe 91552-5 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Extend/snap to pipe 91552-5 and split it there, or confirm the gap is real.
Open
1276ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
9729
Junction 9729 (degree 1) is 0.16 m from pipe 99702-2 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Extend/snap to pipe 99702-2 and split it there, or confirm the gap is real.
Open
1277ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
9739
Junction 9739 (degree 1) is 0.17 m from pipe 89723-9 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Extend/snap to pipe 89723-9 and split it there, or confirm the gap is real.
Open
1278ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
9744
Junction 9744 (degree 1) is 0.09 m from pipe 89723-5 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Extend/snap to pipe 89723-5 and split it there, or confirm the gap is real.
Open
1279ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
9759
Junction 9759 (degree 1) is 0.19 m from pipe 89723-15 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Extend/snap to pipe 89723-15 and split it there, or confirm the gap is real.
Open
1280ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
9764
Junction 9764 (degree 1) is 0.22 m from pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Extend/snap to pipe 89724 and split it there, or confirm the gap is real.
Open
1281ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
9780
Junction 9780 (degree 1) is 0.16 m from pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Extend/snap to pipe 89724 and split it there, or confirm the gap is real.
Open
1282ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
9787
Junction 9787 (degree 1) is 0.08 m from pipe 89723-20 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Extend/snap to pipe 89723-20 and split it there, or confirm the gap is real.
Open
1283ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
9810
Junction 9810 (degree 1) is 0.26 m from pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Extend/snap to pipe 89724 and split it there, or confirm the gap is real.
Open
1284ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
9816
Junction 9816 (degree 1) is 0.12 m from pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Extend/snap to pipe 89724 and split it there, or confirm the gap is real.
Open
1285ERROR
P95
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
9818
Junction 9818 (degree 1) is 0.15 m from pipe 89724 (DN 63, distribution) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Extend/snap to pipe 89724 and split it there, or confirm the gap is real.
Open
1286ERROR
P93
Missing pipe diameter · 1567 features
ATTR_DIAMETER_MISSING
Completeness
Pipe_Functional_Rev04
1,567 Pipe_Functional_Rev04 features
1,567 of 3,754 Pipe_Functional_Rev04 features (42%): missing pipe diameter. Example: Pipe 56368 has diameter 0 (placeholder); material 'PE'. 96% of them have Material = 'Unknown', which points to a systematic gap for that group.
→ Enter the nominal diameter from records or field survey. This is a systematic data gap: fix it in bulk in the source system.
Open
1287ERROR
P89
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89702
Junction 89702 (degree 1) is 0.67 m from pipe 89528 (DN 110, hydrant) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (36 m).
→ Extend/snap to pipe 89528 and split it there, or confirm the gap is real.
Open
1288ERROR
P88
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
4 pipes near 77106
4 pipe(s), 285 m in total incl. 4 main(s), are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1289ERROR
P88
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78558
Junction 78558 (degree 1) is 0.36 m from pipe 65670 (DN 20, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 3 pipe(s) (8 m).
→ Extend/snap to pipe 65670 and split it there, or confirm the gap is real.
Open
1290ERROR
P88
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78641
Junction 78641 (degree 1) is 0.88 m from pipe 60593 (DN 50, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 4 pipe(s) (26 m).
→ Extend/snap to pipe 60593 and split it there, or confirm the gap is real.
Open
1291ERROR
P86
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
86774
Junction 86774 (degree 1) is 0.52 m from pipe 65452 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 2 pipe(s) (22 m).
→ Extend/snap to pipe 65452 and split it there, or confirm the gap is real.
Open
1292ERROR
P85
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
2 pipes near 76999
2 pipe(s), 37 m in total incl. 2 main(s), are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1293ERROR
P85
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
3017
Junction 3017 (degree 1) lies on pipe 60726 (DN 25, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 60726 at junction 3017 so both are connected.
Open
1294ERROR
P85
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
67525
Junction 67525 (degree 5) lies on pipe 59013 (DN 40, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 59013 at junction 67525 so both are connected.
Open
1295ERROR
P85
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
75928
Junction 75928 (degree 2) lies on pipe 65705 (DN 100, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 65705 at junction 75928 so both are connected.
Open
1296ERROR
P85
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89371
Junction 89371 (degree 1) lies on pipe 65717 (DN 31.75, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (24 m).
→ Split pipe 65717 at junction 89371 so both are connected.
Open
1297ERROR
P85
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89383
Junction 89383 (degree 1) lies on pipe 65717 (DN 31.75, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 65717 at junction 89383 so both are connected.
Open
1298ERROR
P85
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89397
Junction 89397 (degree 1) lies on pipe 65717 (DN 31.75, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (23 m).
→ Split pipe 65717 at junction 89397 so both are connected.
Open
1299ERROR
P85
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89399
Junction 89399 (degree 1) lies on pipe 65717 (DN 31.75, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Split pipe 65717 at junction 89399 so both are connected.
Open
1300ERROR
P85
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89401
Junction 89401 (degree 1) lies on pipe 65717 (DN 31.75, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Split pipe 65717 at junction 89401 so both are connected.
Open
1301ERROR
P85
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89467
Junction 89467 (degree 1) lies on pipe 65716 (DN 25, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 65716 at junction 89467 so both are connected.
Open
1302ERROR
P85
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89487
Junction 89487 (degree 1) lies on pipe 56559 (DN 25, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Split pipe 56559 at junction 89487 so both are connected.
Open
1303ERROR
P85
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89596
Junction 89596 (degree 1) lies on pipe 56559 (DN 25, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (37 m).
→ Split pipe 56559 at junction 89596 so both are connected.
Open
1304ERROR
P85
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89598
Junction 89598 (degree 1) lies on pipe 56559 (DN 25, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Split pipe 56559 at junction 89598 so both are connected.
Open
1305ERROR
P85
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89600
Junction 89600 (degree 1) lies on pipe 56559 (DN 25, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (11 m).
→ Split pipe 56559 at junction 89600 so both are connected.
Open
1306ERROR
P85
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89741
Junction 89741 (degree 1) lies on pipe 65674 (DN 100, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (19 m).
→ Split pipe 65674 at junction 89741 so both are connected.
Open
1307ERROR
P85
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
89744
Junction 89744 (degree 1) lies on pipe 65691 (DN 100, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (13 m).
→ Split pipe 65691 at junction 89744 so both are connected.
Open
1308ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
14626
Junction 14626 (degree 1) is 0.98 m from pipe 64035 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Extend/snap to pipe 64035 and split it there, or confirm the gap is real.
Open
1309ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
18663
Junction 18663 (degree 1) is 0.68 m from pipe 93176 (DN 25, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (20 m).
→ Extend/snap to pipe 93176 and split it there, or confirm the gap is real.
Open
1310ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
18667
Junction 18667 (degree 1) is 0.77 m from pipe 93175 (DN 25, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Extend/snap to pipe 93175 and split it there, or confirm the gap is real.
Open
1311ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
18679
Junction 18679 (degree 1) is 0.95 m from pipe 65058 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Extend/snap to pipe 65058 and split it there, or confirm the gap is real.
Open
1312ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
18709
Junction 18709 (degree 1) is 0.49 m from pipe 65060 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (2 m).
→ Extend/snap to pipe 65060 and split it there, or confirm the gap is real.
Open
1313ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
18719
Junction 18719 (degree 1) is 0.37 m from pipe 65055 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Extend/snap to pipe 65055 and split it there, or confirm the gap is real.
Open
1314ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
18772
Junction 18772 (degree 1) is 0.86 m from pipe 93230 (DN 25, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Extend/snap to pipe 93230 and split it there, or confirm the gap is real.
Open
1315ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
18774
Junction 18774 (degree 1) is 0.86 m from pipe 93229 (DN 25, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Extend/snap to pipe 93229 and split it there, or confirm the gap is real.
Open
1316ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
18782
Junction 18782 (degree 1) is 0.92 m from pipe 93235 (DN 25, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Extend/snap to pipe 93235 and split it there, or confirm the gap is real.
Open
1317ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
18784
Junction 18784 (degree 1) is 0.93 m from pipe 93234 (DN 25, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Extend/snap to pipe 93234 and split it there, or confirm the gap is real.
Open
1318ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
72355
Junction 72355 (degree 1) is 0.93 m from pipe 65525 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Extend/snap to pipe 65525 and split it there, or confirm the gap is real.
Open
1319ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78253
Junction 78253 (degree 1) is 0.90 m from pipe 59048 (DN 25, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Extend/snap to pipe 59048 and split it there, or confirm the gap is real.
Open
1320ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78255
Junction 78255 (degree 1) is 0.91 m from pipe 59047 (DN 25, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (4 m).
→ Extend/snap to pipe 59047 and split it there, or confirm the gap is real.
Open
1321ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78532
Junction 78532 (degree 1) is 0.79 m from pipe 65641 (DN 63, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (1 m).
→ Extend/snap to pipe 65641 and split it there, or confirm the gap is real.
Open
1322ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78651
Junction 78651 (degree 1) is 0.27 m from pipe 59251 (DN 25, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Extend/snap to pipe 59251 and split it there, or confirm the gap is real.
Open
1323ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
81376
Junction 81376 (degree 1) is 0.08 m from pipe 93176 (DN 25, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (21 m).
→ Extend/snap to pipe 93176 and split it there, or confirm the gap is real.
Open
1324ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
81377
Junction 81377 (degree 1) is 0.13 m from pipe 93176 (DN 25, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (21 m).
→ Extend/snap to pipe 93176 and split it there, or confirm the gap is real.
Open
1325ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
86448
Junction 86448 (degree 1) is 0.99 m from pipe 65449 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Extend/snap to pipe 65449 and split it there, or confirm the gap is real.
Open
1326ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
86846
Junction 86846 (degree 1) is 0.44 m from pipe 64021 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Extend/snap to pipe 64021 and split it there, or confirm the gap is real.
Open
1327ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
86848
Junction 86848 (degree 1) is 0.49 m from pipe 64020 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (7 m).
→ Extend/snap to pipe 64020 and split it there, or confirm the gap is real.
Open
1328ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
87022
Junction 87022 (degree 1) is 0.66 m from pipe 65453 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Extend/snap to pipe 65453 and split it there, or confirm the gap is real.
Open
1329ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
87085
Junction 87085 (degree 1) is 0.74 m from pipe 64146 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Extend/snap to pipe 64146 and split it there, or confirm the gap is real.
Open
1330ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
87512
Junction 87512 (degree 1) is 0.26 m from pipe 64367 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Extend/snap to pipe 64367 and split it there, or confirm the gap is real.
Open
1331ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
87556
Junction 87556 (degree 1) is 0.55 m from pipe 64392 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Extend/snap to pipe 64392 and split it there, or confirm the gap is real.
Open
1332ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
87736
Junction 87736 (degree 1) is 0.35 m from pipe 65204 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Extend/snap to pipe 65204 and split it there, or confirm the gap is real.
Open
1333ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
87929
Junction 87929 (degree 1) is 0.40 m from pipe 64593 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Extend/snap to pipe 64593 and split it there, or confirm the gap is real.
Open
1334ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
88000
Junction 88000 (degree 1) is 0.73 m from pipe 65344 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (10 m).
→ Extend/snap to pipe 65344 and split it there, or confirm the gap is real.
Open
1335ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
88117
Junction 88117 (degree 1) is 0.86 m from pipe 64688 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Extend/snap to pipe 64688 and split it there, or confirm the gap is real.
Open
1336ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
88119
Junction 88119 (degree 1) is 0.87 m from pipe 64687 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Extend/snap to pipe 64687 and split it there, or confirm the gap is real.
Open
1337ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
88382
Junction 88382 (degree 1) is 0.81 m from pipe 65439 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Extend/snap to pipe 65439 and split it there, or confirm the gap is real.
Open
1338ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
88870
Junction 88870 (degree 1) is 0.52 m from pipe 65300 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (9 m).
→ Extend/snap to pipe 65300 and split it there, or confirm the gap is real.
Open
1339ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89049
Junction 89049 (degree 1) is 0.49 m from pipe 65175 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (17 m).
→ Extend/snap to pipe 65175 and split it there, or confirm the gap is real.
Open
1340ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89077
Junction 89077 (degree 1) is 0.73 m from pipe 65190 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (21 m).
→ Extend/snap to pipe 65190 and split it there, or confirm the gap is real.
Open
1341ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89103
Junction 89103 (degree 1) is 0.35 m from pipe 64484 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (18 m).
→ Extend/snap to pipe 64484 and split it there, or confirm the gap is real.
Open
1342ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89115
Junction 89115 (degree 1) is 0.27 m from pipe 65212 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (22 m).
→ Extend/snap to pipe 65212 and split it there, or confirm the gap is real.
Open
1343ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89117
Junction 89117 (degree 1) is 0.29 m from pipe 65211 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (22 m).
→ Extend/snap to pipe 65211 and split it there, or confirm the gap is real.
Open
1344ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89181
Junction 89181 (degree 1) is 0.57 m from pipe 65365 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Extend/snap to pipe 65365 and split it there, or confirm the gap is real.
Open
1345ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89339
Junction 89339 (degree 1) is 0.84 m from pipe 65327 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (21 m).
→ Extend/snap to pipe 65327 and split it there, or confirm the gap is real.
Open
1346ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89361
Junction 89361 (degree 1) is 0.73 m from pipe 58883 (DN 25, service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (25 m).
→ Extend/snap to pipe 58883 and split it there, or confirm the gap is real.
Open
1347ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89362
Junction 89362 (degree 1) is 0.34 m from pipe 65342 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Extend/snap to pipe 65342 and split it there, or confirm the gap is real.
Open
1348ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89364
Junction 89364 (degree 1) is 0.36 m from pipe 65341 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Extend/snap to pipe 65341 and split it there, or confirm the gap is real.
Open
1349ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89366
Junction 89366 (degree 1) is 0.43 m from pipe 65342 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (6 m).
→ Extend/snap to pipe 65342 and split it there, or confirm the gap is real.
Open
1350ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89404
Junction 89404 (degree 1) is 0.62 m from pipe 65363 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Extend/snap to pipe 65363 and split it there, or confirm the gap is real.
Open
1351ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89406
Junction 89406 (degree 1) is 0.69 m from pipe 65362 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Extend/snap to pipe 65362 and split it there, or confirm the gap is real.
Open
1352ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89410
Junction 89410 (degree 1) is 0.46 m from pipe 65366 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Extend/snap to pipe 65366 and split it there, or confirm the gap is real.
Open
1353ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89412
Junction 89412 (degree 1) is 0.52 m from pipe 65365 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (5 m).
→ Extend/snap to pipe 65365 and split it there, or confirm the gap is real.
Open
1354ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89426
Junction 89426 (degree 1) is 0.20 m from pipe 65374 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Extend/snap to pipe 65374 and split it there, or confirm the gap is real.
Open
1355ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89428
Junction 89428 (degree 1) is 0.20 m from pipe 65373 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (3 m).
→ Extend/snap to pipe 65373 and split it there, or confirm the gap is real.
Open
1356ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89518
Junction 89518 (degree 1) is 0.61 m from pipe 65421 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (8 m).
→ Extend/snap to pipe 65421 and split it there, or confirm the gap is real.
Open
1357ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89531
Junction 89531 (degree 1) is 0.88 m from pipe 65431 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (16 m).
→ Extend/snap to pipe 65431 and split it there, or confirm the gap is real.
Open
1358ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89559
Junction 89559 (degree 1) is 0.50 m from pipe 65442 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (27 m).
→ Extend/snap to pipe 65442 and split it there, or confirm the gap is real.
Open
1359ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89561
Junction 89561 (degree 1) is 0.50 m from pipe 65443 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (29 m).
→ Extend/snap to pipe 65443 and split it there, or confirm the gap is real.
Open
1360ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89563
Junction 89563 (degree 1) is 0.50 m from pipe 65442 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (29 m).
→ Extend/snap to pipe 65442 and split it there, or confirm the gap is real.
Open
1361ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89583
Junction 89583 (degree 1) is 0.55 m from pipe 64113 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (12 m).
→ Extend/snap to pipe 64113 and split it there, or confirm the gap is real.
Open
1362ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89704
Junction 89704 (degree 1) is 0.59 m from pipe 65515 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (59 m).
→ Extend/snap to pipe 65515 and split it there, or confirm the gap is real.
Open
1363ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89705
Junction 89705 (degree 1) is 0.59 m from pipe 65514 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (59 m).
→ Extend/snap to pipe 65514 and split it there, or confirm the gap is real.
Open
1364ERROR
P85
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89931
Junction 89931 (degree 1) is 0.54 m from pipe 64513 (service) but is not connected to it, so the hydraulic model treats them as separate networks. Fixing it reconnects 1 pipe(s) (14 m).
→ Extend/snap to pipe 64513 and split it there, or confirm the gap is real.
Open
1365ERROR
P82
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 53745
1 pipe(s), 13 m in total incl. 1 main(s), are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1366ERROR
P82
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 56535
1 pipe(s), 7 m in total incl. 1 main(s), are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1367ERROR
P82
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 56539
1 pipe(s), 14 m in total incl. 1 main(s), are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1368ERROR
P82
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 56549
1 pipe(s), 24 m in total incl. 1 main(s), are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1369ERROR
P82
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 56550
1 pipe(s), 20 m in total incl. 1 main(s), are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1370ERROR
P82
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 56595
1 pipe(s), 10 m in total incl. 1 main(s), are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1371ERROR
P82
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 93643
1 pipe(s), 26 m in total incl. 1 main(s), are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1372ERROR
P82
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 93647
1 pipe(s), 6 m in total incl. 1 main(s), are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1373ERROR
P82
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 95548
1 pipe(s), 44 m in total incl. 1 main(s), are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1374ERROR
P82
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 95549
1 pipe(s), 2 m in total incl. 1 main(s), are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1375ERROR
P82
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 95551
1 pipe(s), 13 m in total incl. 1 main(s), are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1376ERROR
P80
Zero-length pipe
GEOM_ZERO_LENGTH
Geometry
Pipe_Functional_Rev04
89455-30
Pipe 89455-30 is 0.057 m long (minimum 0.1 m).
→ Delete the degenerate pipe or redraw it.
Open
1377ERROR
P80
Zero-length pipe
GEOM_ZERO_LENGTH
Geometry
Pipe_Functional_Rev04
89498-6
Pipe 89498-6 is 0.099 m long (minimum 0.1 m).
→ Delete the degenerate pipe or redraw it.
Open
1378ERROR
P76
Zero-length pipe
GEOM_ZERO_LENGTH
Geometry
Pipe_Functional_Rev04
56383-1
Pipe 56383-1 is 0.010 m long (minimum 0.1 m).
→ Delete the degenerate pipe or redraw it.
Open
1379ERROR
P76
Zero-length pipe
GEOM_ZERO_LENGTH
Geometry
Pipe_Functional_Rev04
56675-4
Pipe 56675-4 is 0.040 m long (minimum 0.1 m).
→ Delete the degenerate pipe or redraw it.
Open
1380ERROR
P70
Coincident junctions
TOPO_COINCIDENT_NODES
Topology
Junction_Rev03
76044
Junctions 76044 and 19607 are at the same location.
→ Merge them and re-point pipes to the surviving junction.
Open
1381WARNING
P60
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8392
Junction 8392 (degree 1) lies on pipe 53701 (DN 90, transmission) but is not connected to it.
→ Split pipe 53701 at junction 8392 so both are connected.
Open
1382WARNING
P60
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8456
Junction 8456 (degree 1) lies on pipe 56399-1 (DN 90, transmission) but is not connected to it.
→ Split pipe 56399-1 at junction 8456 so both are connected.
Open
1383WARNING
P60
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
20035
Junction 20035 (degree 1) is 0.64 m from pipe 95312 (DN 110, transmission) but is not connected to it.
→ Extend/snap to pipe 95312 and split it there, or confirm the gap is real.
Open
1384WARNING
P60
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
25347
Junction 25347 (degree 1) is 0.99 m from pipe 89713 (DN 160, transmission) but is not connected to it.
→ Extend/snap to pipe 89713 and split it there, or confirm the gap is real.
Open
1385WARNING
P60
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
58411
Junction 58411 (degree 1) is 0.33 m from pipe 56493-1 (DN 150, transmission) but is not connected to it.
→ Extend/snap to pipe 56493-1 and split it there, or confirm the gap is real.
Open
1386WARNING
P60
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
58412
Junction 58412 (degree 1) is 0.85 m from pipe 52864 (DN 100, transmission) but is not connected to it.
→ Extend/snap to pipe 52864 and split it there, or confirm the gap is real.
Open
1387WARNING
P60
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
58415
Junction 58415 (degree 1) is 0.85 m from pipe 56397 (DN 63, transmission) but is not connected to it.
→ Extend/snap to pipe 56397 and split it there, or confirm the gap is real.
Open
1388WARNING
P60
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
58419
Junction 58419 (degree 1) is 0.84 m from pipe 52888 (DN 150, transmission) but is not connected to it.
→ Extend/snap to pipe 52888 and split it there, or confirm the gap is real.
Open
1389WARNING
P60
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
58435
Junction 58435 (degree 1) is 0.19 m from pipe 56451-2 (DN 100, transmission) but is not connected to it.
→ Extend/snap to pipe 56451-2 and split it there, or confirm the gap is real.
Open
1390WARNING
P60
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
58459
Junction 58459 (degree 1) is 0.25 m from pipe 56591 (DN 63, transmission) but is not connected to it.
→ Extend/snap to pipe 56591 and split it there, or confirm the gap is real.
Open
1391WARNING
P60
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
67588
Junction 67588 (degree 1) is 0.79 m from pipe 89530-4 (DN 110, transmission) but is not connected to it.
→ Extend/snap to pipe 89530-4 and split it there, or confirm the gap is real.
Open
1392WARNING
P60
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
76049
Junction 76049 (degree 1) is 0.67 m from pipe 89469-1 (DN 110, transmission) but is not connected to it.
→ Extend/snap to pipe 89469-1 and split it there, or confirm the gap is real.
Open
1393WARNING
P60
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
77378
Junction 77378 (degree 1) is 0.80 m from pipe 89498-4 (DN 110, transmission) but is not connected to it.
→ Extend/snap to pipe 89498-4 and split it there, or confirm the gap is real.
Open
1394WARNING
P60
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
8396
Junction 8396 (degree 1) is 0.74 m from pipe 99643-3 (DN 75, transmission) but is not connected to it.
→ Extend/snap to pipe 99643-3 and split it there, or confirm the gap is real.
Open
1395WARNING
P60
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
8398
Junction 8398 (degree 1) is 0.34 m from pipe 99643-3 (DN 75, transmission) but is not connected to it.
→ Extend/snap to pipe 99643-3 and split it there, or confirm the gap is real.
Open
1396WARNING
P56
Missing or unknown pipe material · 1511 features
ATTR_MATERIAL_MISSING
Completeness
Pipe_Functional_Rev04
1,511 Pipe_Functional_Rev04 features
1,511 of 3,754 Pipe_Functional_Rev04 features (40%): missing or unknown pipe material. Example: Pipe 58901 material is “Unknown”.
→ Record the pipe material (affects roughness, failure risk and renewal planning). This is a systematic data gap: fix it in bulk in the source system.
Open
1397WARNING
P52
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
8268
Junction 8268 (degree 1) lies on pipe 89420 (DN 90, distribution) but is not connected to it.
→ Split pipe 89420 at junction 8268 so both are connected.
Open
1398WARNING
P52
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
9420
Junction 9420 (degree 1) lies on pipe 56490 (DN 32, distribution) but is not connected to it.
→ Split pipe 56490 at junction 9420 so both are connected.
Open
1399WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
58431
Junction 58431 (degree 1) is 0.31 m from pipe 52817 (DN 150, distribution) but is not connected to it.
→ Extend/snap to pipe 52817 and split it there, or confirm the gap is real.
Open
1400WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
58461
Junction 58461 (degree 1) is 0.35 m from pipe 56625-15 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 56625-15 and split it there, or confirm the gap is real.
Open
1401WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
58468
Junction 58468 (degree 1) is 0.61 m from pipe 56635-7 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 56635-7 and split it there, or confirm the gap is real.
Open
1402WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
76034
Junction 76034 (degree 1) is 0.63 m from pipe 56635-8 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 56635-8 and split it there, or confirm the gap is real.
Open
1403WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
7786
Junction 7786 (degree 1) is 0.92 m from pipe 89361 (DN 63, distribution) but is not connected to it.
→ Extend/snap to pipe 89361 and split it there, or confirm the gap is real.
Open
1404WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
7793
Junction 7793 (degree 1) is 0.76 m from pipe 89375 (DN 63, distribution) but is not connected to it.
→ Extend/snap to pipe 89375 and split it there, or confirm the gap is real.
Open
1405WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
7795
Junction 7795 (degree 1) is 0.97 m from pipe 89378 (DN 63, distribution) but is not connected to it.
→ Extend/snap to pipe 89378 and split it there, or confirm the gap is real.
Open
1406WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78325
Junction 78325 (degree 1) is 0.87 m from pipe 56633-38 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 56633-38 and split it there, or confirm the gap is real.
Open
1407WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78333
Junction 78333 (degree 1) is 0.48 m from pipe 56633-33 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 56633-33 and split it there, or confirm the gap is real.
Open
1408WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78335
Junction 78335 (degree 1) is 0.99 m from pipe 56633-31 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 56633-31 and split it there, or confirm the gap is real.
Open
1409WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78337
Junction 78337 (degree 1) is 0.77 m from pipe 56633-30 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 56633-30 and split it there, or confirm the gap is real.
Open
1410WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78371
Junction 78371 (degree 1) is 0.75 m from pipe 56633-12 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 56633-12 and split it there, or confirm the gap is real.
Open
1411WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78373
Junction 78373 (degree 1) is 0.97 m from pipe 56633-10 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 56633-10 and split it there, or confirm the gap is real.
Open
1412WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78511
Junction 78511 (degree 1) is 0.43 m from pipe 89472-1 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 89472-1 and split it there, or confirm the gap is real.
Open
1413WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
8527
Junction 8527 (degree 1) is 0.95 m from pipe 56637-13 (distribution) but is not connected to it.
→ Extend/snap to pipe 56637-13 and split it there, or confirm the gap is real.
Open
1414WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
8629
Junction 8629 (degree 1) is 0.78 m from pipe 56633-25 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 56633-25 and split it there, or confirm the gap is real.
Open
1415WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
8638
Junction 8638 (degree 1) is 0.32 m from pipe 56633-32 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 56633-32 and split it there, or confirm the gap is real.
Open
1416WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
8641
Junction 8641 (degree 1) is 0.61 m from pipe 56633-41 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 56633-41 and split it there, or confirm the gap is real.
Open
1417WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
8648
Junction 8648 (degree 1) is 0.66 m from pipe 56633-36 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 56633-36 and split it there, or confirm the gap is real.
Open
1418WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
8650
Junction 8650 (degree 1) is 0.67 m from pipe 56633-35 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 56633-35 and split it there, or confirm the gap is real.
Open
1419WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
8652
Junction 8652 (degree 1) is 0.64 m from pipe 56633-34 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 56633-34 and split it there, or confirm the gap is real.
Open
1420WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
8655
Junction 8655 (degree 1) is 0.86 m from pipe 56633-36 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 56633-36 and split it there, or confirm the gap is real.
Open
1421WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
8657
Junction 8657 (degree 1) is 0.38 m from pipe 56633-42 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 56633-42 and split it there, or confirm the gap is real.
Open
1422WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89961
Junction 89961 (degree 1) is 0.69 m from pipe 89706-2 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 89706-2 and split it there, or confirm the gap is real.
Open
1423WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
90047
Junction 90047 (degree 1) is 0.71 m from pipe 56633-10 (DN 110, distribution) but is not connected to it.
→ Extend/snap to pipe 56633-10 and split it there, or confirm the gap is real.
Open
1424WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
9058
Junction 9058 (degree 1) is 0.62 m from pipe 89587 (DN 63, distribution) but is not connected to it.
→ Extend/snap to pipe 89587 and split it there, or confirm the gap is real.
Open
1425WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
9059
Junction 9059 (degree 1) is 0.74 m from pipe 89595 (DN 63, distribution) but is not connected to it.
→ Extend/snap to pipe 89595 and split it there, or confirm the gap is real.
Open
1426WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
9060
Junction 9060 (degree 1) is 0.45 m from pipe 89596 (DN 63, distribution) but is not connected to it.
→ Extend/snap to pipe 89596 and split it there, or confirm the gap is real.
Open
1427WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
9062
Junction 9062 (degree 1) is 0.78 m from pipe 89548-2 (DN 75, distribution) but is not connected to it.
→ Extend/snap to pipe 89548-2 and split it there, or confirm the gap is real.
Open
1428WARNING
P52
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
9071
Junction 9071 (degree 1) is 0.83 m from pipe 89542-2 (DN 90, distribution) but is not connected to it.
→ Extend/snap to pipe 89542-2 and split it there, or confirm the gap is real.
Open
1429WARNING
P50
Abrupt diameter change
ATTR_DIAMETER_JUMP
Plausibility
Pipe_Functional_Rev04
56501-1
Diameter drops from 100 mm (52878) to 20 mm (56501-1) at a simple connection.
→ Check for a typo in either diameter, or a missing branch/reducer.
Open
1430WARNING
P50
Abrupt diameter change
ATTR_DIAMETER_JUMP
Plausibility
Pipe_Functional_Rev04
59075
Diameter drops from 110 mm (56641-7) to 25 mm (59075) at a simple connection.
→ Check for a typo in either diameter, or a missing branch/reducer.
Open
1431WARNING
P50
Abrupt diameter change
ATTR_DIAMETER_JUMP
Plausibility
Pipe_Functional_Rev04
59080
Diameter drops from 110 mm (56641-1) to 25 mm (59080) at a simple connection.
→ Check for a typo in either diameter, or a missing branch/reducer.
Open
1432WARNING
P50
Abrupt diameter change
ATTR_DIAMETER_JUMP
Plausibility
Pipe_Functional_Rev04
89619-1
Diameter drops from 150 mm (56562) to 25.4 mm (89619-1) at a simple connection.
→ Check for a typo in either diameter, or a missing branch/reducer.
Open
1433WARNING
P50
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
52847
Pipes 52847 (DN 150, transmission) and 89713 (DN 160, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1434WARNING
P50
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
52857
Pipes 52857 (DN 150, transmission) and 89718-2 (DN 150, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1435WARNING
P50
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
52889
Pipes 52889 (DN 150, transmission) and 89468 (DN 110, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1436WARNING
P50
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53726
Pipes 53726 (DN 110, transmission) and 89718-2 (DN 150, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1437WARNING
P50
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53727
Pipes 53727 (DN 32, transmission) and 56551 (DN 125, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1438WARNING
P50
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53728
Pipes 53728 (DN 40, transmission) and 89522-2 (DN 110, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1439WARNING
P50
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53745
Pipes 53745 (DN 110, transmission) and 53746 (DN 160, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1440WARNING
P50
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56468-2
Pipes 56468-2 (DN 63, transmission) and 89530-4 (DN 110, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1441WARNING
P50
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56469
Pipes 56469 (DN 63, transmission) and 95343 (DN 110, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1442WARNING
P50
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56473
Pipes 56473 (DN 100, transmission) and 89713 (DN 160, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1443WARNING
P50
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56562
Pipes 56562 (DN 150, transmission) and 89718-2 (DN 150, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1444WARNING
P50
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56591
Pipes 56591 (DN 63, transmission) and 56659-1 (DN 110, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1445WARNING
P50
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
65346-9
Pipes 65346-9 (DN 19.05, transmission) and 89718-1 (DN 150, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1446WARNING
P50
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
89518
Pipes 89518 (DN 110, transmission) and 56451-2 (DN 100, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1447WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
52823
Pipes 52823 (DN 150, distribution) and 102634-1 (DN 50, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1448WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
52836
Pipes 52836 (DN 200, distribution) and 56618-1 (DN 110, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1449WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
52836
Pipes 52836 (DN 200, distribution) and 56451-2 (DN 100, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1450WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
52836
Pipes 52836 (DN 200, distribution) and 89518 (DN 110, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1451WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
52836
Pipes 52836 (DN 200, distribution) and 56617-1 (DN 110, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1452WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
52847
Pipes 52847 (DN 150, transmission) and 52870 (DN 150, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1453WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
52867
Pipes 52867 (DN 200, distribution) and 65346-9 (DN 19.05, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1454WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
52870
Pipes 52870 (DN 150, distribution) and 56473 (DN 100, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1455WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
52870
Pipes 52870 (DN 150, distribution) and 89713 (DN 160, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1456WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
52898
Pipes 52898 (DN 150, transmission) and 56508 (distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1457WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
52916
Pipes 52916 (DN 150, distribution) and 89501-13 (DN 110, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1458WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53519
Pipes 53519 (DN 150, distribution) and 76999 (DN 110, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1459WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56380
Pipes 56380 (DN 90, distribution) and 95582 (DN 160, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1460WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56439
Pipes 56439 (DN 63, distribution) and 56619-11 (DN 110, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1461WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56473
Pipes 56473 (DN 100, transmission) and 99702-4 (DN 63, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1462WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56490
Pipes 56490 (DN 32, distribution) and 89712 (DN 160, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1463WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56542
Pipes 56542 (DN 200, distribution) and 93643 (DN 355, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1464WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56544
Pipes 56544 (DN 300, distribution) and 56545 (DN 200, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1465WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56548
Pipes 56548 (DN 150, distribution) and 77106 (DN 160, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1466WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56568
Pipes 56568 (DN 63, distribution) and 89714 (DN 160, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1467WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56576
Pipes 56576 (DN 63, distribution) and 89714 (DN 160, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1468WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
89379
Pipes 89379 (DN 110, transmission) and 89381-1 (DN 110, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1469WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
89481
Pipes 89481 (DN 90, distribution) and 95580 (DN 160, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1470WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
89481
Pipes 89481 (DN 90, distribution) and 95579 (DN 160, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1471WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
89481
Pipes 89481 (DN 90, distribution) and 95578 (DN 160, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1472WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
89613
Pipes 89613 (DN 110, distribution) and 95582 (DN 160, transmission) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1473WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
89713
Pipes 89713 (DN 160, transmission) and 99701 (DN 63, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1474WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
93643
Pipes 93643 (DN 355, transmission) and 95548 (DN 355, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1475WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
95581
Pipes 95581 (DN 160, transmission) and 56366-1 (DN 90, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1476WARNING
P48
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
95582
Pipes 95582 (DN 160, transmission) and 56366-1 (DN 90, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1477WARNING
P48
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
3 pipes near 65715
3 pipe(s), 26 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1478WARNING
P47
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
2 pipes near 63872
2 pipe(s), 19 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1479WARNING
P47
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
2 pipes near 63886
2 pipe(s), 20 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1480WARNING
P47
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
2 pipes near 63928
2 pipe(s), 18 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1481WARNING
P47
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
2 pipes near 64695
2 pipe(s), 19 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1482WARNING
P47
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
2 pipes near 64697
2 pipe(s), 11 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1483WARNING
P47
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
2 pipes near 65128
2 pipe(s), 14 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1484WARNING
P47
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
2 pipes near 65254
2 pipe(s), 12 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1485WARNING
P47
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
2 pipes near 65256
2 pipe(s), 13 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1486WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53737
Pipes 53737 (DN 110, distribution) and 56633-42 (DN 110, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1487WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53737
Pipes 53737 (DN 110, distribution) and 56633-40 (DN 110, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1488WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53737
Pipes 53737 (DN 110, distribution) and 56633-38 (DN 110, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1489WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53737
Pipes 53737 (DN 110, distribution) and 56633-29 (DN 110, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1490WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53737
Pipes 53737 (DN 110, distribution) and 56633-27 (DN 110, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1491WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53737
Pipes 53737 (DN 110, distribution) and 56633-25 (DN 110, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1492WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53737
Pipes 53737 (DN 110, distribution) and 56633-24 (DN 110, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1493WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53748
Pipes 53748 (DN 110, distribution) and 56527 (DN 63, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1494WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53748
Pipes 53748 (DN 110, distribution) and 56549 (distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1495WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53748
Pipes 53748 (DN 110, distribution) and 56550 (distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1496WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53748
Pipes 53748 (DN 110, distribution) and 56543 (DN 150, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1497WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53748
Pipes 53748 (DN 110, distribution) and 56548 (DN 150, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1498WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53748
Pipes 53748 (DN 110, distribution) and 56542 (DN 200, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1499WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
53748
Pipes 53748 (DN 110, distribution) and 95548 (DN 355, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1500WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56371
Pipes 56371 (DN 63, distribution) and 89472-4 (DN 110, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1501WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56380
Pipes 56380 (DN 90, distribution) and 89613 (DN 110, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1502WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56384
Pipes 56384 (DN 150, distribution) and 89472-4 (DN 110, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1503WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56527
Pipes 56527 (DN 63, distribution) and 56544 (DN 300, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1504WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56539
Pipes 56539 (distribution) and 56549 (distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1505WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56539
Pipes 56539 (distribution) and 95548 (DN 355, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1506WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56542
Pipes 56542 (DN 200, distribution) and 95548 (DN 355, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1507WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56543
Pipes 56543 (DN 150, distribution) and 56549 (distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1508WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56543
Pipes 56543 (DN 150, distribution) and 95548 (DN 355, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1509WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56549
Pipes 56549 (distribution) and 95548 (DN 355, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1510WARNING
P46
Pipes cross without a junction
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
56550
Pipes 56550 (distribution) and 95548 (DN 355, distribution) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction.
Open
1511WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 59281
1 pipe(s), 2 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1512WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 59291
1 pipe(s), 21 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1513WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63832
1 pipe(s), 11 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1514WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63858
1 pipe(s), 4 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1515WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63884
1 pipe(s), 9 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1516WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63923
1 pipe(s), 7 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1517WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63924
1 pipe(s), 16 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1518WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63925
1 pipe(s), 12 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1519WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63926
1 pipe(s), 9 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1520WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63929
1 pipe(s), 6 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1521WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63930
1 pipe(s), 14 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1522WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63931
1 pipe(s), 8 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1523WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63932
1 pipe(s), 12 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1524WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63933
1 pipe(s), 11 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1525WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63934
1 pipe(s), 18 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1526WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63935
1 pipe(s), 16 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1527WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63936
1 pipe(s), 14 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1528WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63937
1 pipe(s), 17 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1529WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63938
1 pipe(s), 13 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1530WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63939
1 pipe(s), 13 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1531WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63940
1 pipe(s), 14 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1532WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63941
1 pipe(s), 15 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1533WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63942
1 pipe(s), 15 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1534WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63943
1 pipe(s), 13 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1535WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63944
1 pipe(s), 18 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1536WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63945
1 pipe(s), 17 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1537WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63946
1 pipe(s), 19 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1538WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63947
1 pipe(s), 15 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1539WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63948
1 pipe(s), 13 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1540WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 63949
1 pipe(s), 13 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1541WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 64077
1 pipe(s), 9 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1542WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 64692
1 pipe(s), 8 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1543WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 64693
1 pipe(s), 6 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1544WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 64694
1 pipe(s), 6 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1545WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 64696
1 pipe(s), 5 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1546WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 64698
1 pipe(s), 12 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1547WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 64699
1 pipe(s), 6 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1548WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 64700
1 pipe(s), 5 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1549WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 64701
1 pipe(s), 3 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1550WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 64702
1 pipe(s), 4 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1551WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 64704
1 pipe(s), 5 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1552WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 64706
1 pipe(s), 7 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1553WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 64707
1 pipe(s), 5 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1554WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 64709
1 pipe(s), 5 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1555WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 64710
1 pipe(s), 4 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1556WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 65137
1 pipe(s), 7 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1557WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 65253
1 pipe(s), 7 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1558WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 65255
1 pipe(s), 23 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1559WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 65257
1 pipe(s), 4 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1560WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 65386
1 pipe(s), 10 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1561WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 65485
1 pipe(s), 71 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1562WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 65514
1 pipe(s), 59 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1563WARNING
P44
Network part not connected to supply
TOPO_DISCONNECTED
Topology
Pipe_Functional_Rev04
1 pipes near 65515
1 pipe(s), 83 m in total, are not connected to the main network.
→ Find the missing connection (unsnapped end, missing pipe or junction); if this is a separate system, add its source.
Open
1564WARNING
P42
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
67601
Junction 67601 (degree 2) lies on pipe 65660 (DN 40, service) but is not connected to it.
→ Split pipe 65660 at junction 67601 so both are connected.
Open
1565WARNING
P42
Junction touches a pipe but is not connected
TOPO_NODE_ON_PIPE
Topology
Junction_Rev03
78644
Junction 78644 (degree 1) lies on pipe 59248 (DN 25, service) but is not connected to it.
→ Split pipe 59248 at junction 78644 so both are connected.
Open
1566WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
18656
Junction 18656 (degree 1) is 0.11 m from pipe 93172 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 93172 and split it there, or confirm the gap is real.
Open
1567WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
32082
Junction 32082 (degree 1) is 0.85 m from pipe 59215 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 59215 and split it there, or confirm the gap is real.
Open
1568WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
32084
Junction 32084 (degree 1) is 0.86 m from pipe 59214 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 59214 and split it there, or confirm the gap is real.
Open
1569WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
58454
Junction 58454 (degree 1) is 0.71 m from pipe 59324 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 59324 and split it there, or confirm the gap is real.
Open
1570WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
77487
Junction 77487 (degree 1) is 0.59 m from pipe 58674 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 58674 and split it there, or confirm the gap is real.
Open
1571WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
77511
Junction 77511 (degree 1) is 0.59 m from pipe 58662 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 58662 and split it there, or confirm the gap is real.
Open
1572WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
77900
Junction 77900 (degree 1) is 0.93 m from pipe 58871 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 58871 and split it there, or confirm the gap is real.
Open
1573WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
77903
Junction 77903 (degree 1) is 0.93 m from pipe 58870 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 58870 and split it there, or confirm the gap is real.
Open
1574WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
77966
Junction 77966 (degree 1) is 0.70 m from pipe 59244 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 59244 and split it there, or confirm the gap is real.
Open
1575WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
77982
Junction 77982 (degree 1) is 0.55 m from pipe 59222 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 59222 and split it there, or confirm the gap is real.
Open
1576WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78132
Junction 78132 (degree 1) is 0.88 m from pipe 60592 (DN 50, service) but is not connected to it.
→ Extend/snap to pipe 60592 and split it there, or confirm the gap is real.
Open
1577WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78176
Junction 78176 (degree 1) is 0.59 m from pipe 59009 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 59009 and split it there, or confirm the gap is real.
Open
1578WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78178
Junction 78178 (degree 1) is 0.85 m from pipe 59008 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 59008 and split it there, or confirm the gap is real.
Open
1579WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78206
Junction 78206 (degree 1) is 0.92 m from pipe 59024 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 59024 and split it there, or confirm the gap is real.
Open
1580WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78208
Junction 78208 (degree 1) is 0.92 m from pipe 59023 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 59023 and split it there, or confirm the gap is real.
Open
1581WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78599
Junction 78599 (degree 1) is 0.67 m from pipe 58911 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 58911 and split it there, or confirm the gap is real.
Open
1582WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78607
Junction 78607 (degree 1) is 0.72 m from pipe 59244 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 59244 and split it there, or confirm the gap is real.
Open
1583WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78627
Junction 78627 (degree 1) is 0.96 m from pipe 89504 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 89504 and split it there, or confirm the gap is real.
Open
1584WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78635
Junction 78635 (degree 1) is 0.69 m from pipe 59226 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 59226 and split it there, or confirm the gap is real.
Open
1585WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78726
Junction 78726 (degree 1) is 0.81 m from pipe 65740 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 65740 and split it there, or confirm the gap is real.
Open
1586WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78732
Junction 78732 (degree 1) is 0.80 m from pipe 59300 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 59300 and split it there, or confirm the gap is real.
Open
1587WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
78734
Junction 78734 (degree 1) is 0.80 m from pipe 59299 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 59299 and split it there, or confirm the gap is real.
Open
1588WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
81353
Junction 81353 (degree 1) is 0.24 m from pipe 65667 (DN 16, service) but is not connected to it.
→ Extend/snap to pipe 65667 and split it there, or confirm the gap is real.
Open
1589WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
81355
Junction 81355 (degree 1) is 0.21 m from pipe 60692 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 60692 and split it there, or confirm the gap is real.
Open
1590WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
81356
Junction 81356 (degree 1) is 0.20 m from pipe 60691 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 60691 and split it there, or confirm the gap is real.
Open
1591WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
81379
Junction 81379 (degree 1) is 0.39 m from pipe 60726 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 60726 and split it there, or confirm the gap is real.
Open
1592WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
81380
Junction 81380 (degree 1) is 0.39 m from pipe 60723 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 60723 and split it there, or confirm the gap is real.
Open
1593WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
81381
Junction 81381 (degree 1) is 0.41 m from pipe 60724 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 60724 and split it there, or confirm the gap is real.
Open
1594WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
81382
Junction 81382 (degree 1) is 0.34 m from pipe 60727 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 60727 and split it there, or confirm the gap is real.
Open
1595WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
81383
Junction 81383 (degree 1) is 0.34 m from pipe 60726 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 60726 and split it there, or confirm the gap is real.
Open
1596WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
86470
Junction 86470 (degree 1) is 0.30 m from pipe 65450 (service) but is not connected to it.
→ Extend/snap to pipe 65450 and split it there, or confirm the gap is real.
Open
1597WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89037
Junction 89037 (degree 1) is 0.72 m from pipe 65169 (service) but is not connected to it.
→ Extend/snap to pipe 65169 and split it there, or confirm the gap is real.
Open
1598WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89955
Junction 89955 (degree 1) is 0.67 m from pipe 65654 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 65654 and split it there, or confirm the gap is real.
Open
1599WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89956
Junction 89956 (degree 1) is 0.67 m from pipe 65653 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 65653 and split it there, or confirm the gap is real.
Open
1600WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89957
Junction 89957 (degree 1) is 0.35 m from pipe 65660 (DN 40, service) but is not connected to it.
→ Extend/snap to pipe 65660 and split it there, or confirm the gap is real.
Open
1601WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89962
Junction 89962 (degree 1) is 0.35 m from pipe 65655 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 65655 and split it there, or confirm the gap is real.
Open
1602WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89969
Junction 89969 (degree 1) is 0.23 m from pipe 60689 (DN 40, service) but is not connected to it.
→ Extend/snap to pipe 60689 and split it there, or confirm the gap is real.
Open
1603WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
89970
Junction 89970 (degree 1) is 0.27 m from pipe 65667 (DN 16, service) but is not connected to it.
→ Extend/snap to pipe 65667 and split it there, or confirm the gap is real.
Open
1604WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
90022
Junction 90022 (degree 1) is 0.74 m from pipe 65736 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 65736 and split it there, or confirm the gap is real.
Open
1605WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
90024
Junction 90024 (degree 1) is 0.74 m from pipe 65735 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 65735 and split it there, or confirm the gap is real.
Open
1606WARNING
P42
Pipe end not connected (snapping gap)
TOPO_UNCONNECTED_END
Topology
Junction_Rev03
90032
Junction 90032 (degree 1) is 0.77 m from pipe 59296 (DN 25, service) but is not connected to it.
→ Extend/snap to pipe 59296 and split it there, or confirm the gap is real.
Open
1607WARNING
P40
Missing elevation
ATTR_ELEVATION_MISSING
Completeness
Junction_Rev03
20333
Junction 20333 elevation is empty.
→ Enter the surveyed elevation or interpolate from a DEM.
Open
1608WARNING
P40
Missing elevation
ATTR_ELEVATION_MISSING
Completeness
Junction_Rev03
20350
Junction 20350 elevation is empty.
→ Enter the surveyed elevation or interpolate from a DEM.
Open
1609WARNING
P40
Missing elevation
ATTR_ELEVATION_MISSING
Completeness
Junction_Rev03
20351
Junction 20351 elevation is empty.
→ Enter the surveyed elevation or interpolate from a DEM.
Open
1610WARNING
P40
Missing elevation
ATTR_ELEVATION_MISSING
Completeness
Junction_Rev03
20352
Junction 20352 elevation is empty.
→ Enter the surveyed elevation or interpolate from a DEM.
Open
1611WARNING
P40
Missing elevation
ATTR_ELEVATION_MISSING
Completeness
Junction_Rev03
20353
Junction 20353 elevation is empty.
→ Enter the surveyed elevation or interpolate from a DEM.
Open
1612WARNING
P40
Missing elevation
ATTR_ELEVATION_MISSING
Completeness
Junction_Rev03
20354
Junction 20354 elevation is empty.
→ Enter the surveyed elevation or interpolate from a DEM.
Open
1613WARNING
P40
Missing elevation
ATTR_ELEVATION_MISSING
Completeness
Junction_Rev03
20356
Junction 20356 elevation is empty.
→ Enter the surveyed elevation or interpolate from a DEM.
Open
1614WARNING
P40
Elevation outlier
ATTR_ELEVATION_OUTLIER
Plausibility
Junction_Rev03
9411
Junction 9411 is at 198.2 m while its 2 neighbours are around 178.4 m (+19.8 m).
→ Check for a typo or wrong datum; correct the elevation if it is not a real step.
Open
1615INFO
P26
Missing installation year · 2119 features
ATTR_YEAR_MISSING
Completeness
Pipe_Functional_Rev04
2,119 Pipe_Functional_Rev04 features
2,119 of 3,754 Pipe_Functional_Rev04 features (56%): missing installation year. Example: Pipe 52740 has no installation year.
→ Record the installation year (needed for asset-age and renewal planning). This is a systematic data gap: fix it in bulk in the source system.
Open
1616INFO
P21
Pipes cross without a junction · 883 features
TOPO_CROSSING
Topology
Pipe_Functional_Rev04
883 Pipe_Functional_Rev04 features
883 cases involving 556 of 3,754 Pipe_Functional_Rev04 features (15%): pipes cross without a junction. Example: Pipes 52817 (DN 150, distribution) and 64434 (service) cross without a shared junction.
→ Confirm it is a crossing at different depths; otherwise split both pipes and add a junction. This is a systematic data gap: fix it in bulk in the source system.
Open